The Markham Meyerding Hemilaminectomy Retractor is a specialized spinal surgical retractor designed for controlled exposure during hemilaminectomy and related procedures. The instrument is available in two opposing working-end configurations, allowing the surgeon or purchasing team to select whether the retractor blade is positioned on the left or right side.
The current Peak Surgicals product is identified by storefront SKU PS-OT-0985 and is manufactured from German stainless steel. Available configurations include PS-8754 with blade on right and sharp tenaculum on left and PS-8753 with blade on left and sharp tenaculum on right.
The Markham Meyerding pattern is a specialized retractor associated with spinal and hemilaminectomy instrument sets. Its asymmetrical working-end configuration combines a retractor blade on one side with a sharp tenaculum on the opposite side.
This design allows the required left/right configuration to be selected according to operative access and surgeon preference.
The PS-8754 configuration is listed with the retractor blade on the right side and the sharp tenaculum on the left.
This orientation should be clearly specified when ordering because PS-8754 and PS-8753 represent opposite working-end arrangements.
The PS-8753 configuration reverses the working ends, providing the retractor blade on the left side and the sharp tenaculum on the right.
Buyers should confirm the surgeon's preferred orientation before selecting between the two available configurations.
The Markham Meyerding pattern is established within surgical instrument catalogs as a self-retaining hemilaminectomy retractor. This type of retractor is intended to maintain surgical exposure after the required opening has been established.
The exact locking mechanism, opening capacity, and mechanical dimensions of the current Peak Surgicals model are not stated on the product page and should therefore be confirmed when those specifications are required.
The Markham Meyerding pattern is intended for spinal surgical exposure, particularly within instrument sets used for hemilaminectomy and related posterior spinal procedures.
The exact placement, degree of retraction, and required left/right working-end configuration should be determined by the operating surgeon according to the surgical approach and anatomy.
Unlike retractors with identical blades on both sides, this model combines a retractor blade with an opposing sharp tenaculum. The two available variants reverse the orientation of these working components.
The current Peak Surgicals page does not specify the blade depth, blade width, tenaculum dimensions, number of sharp points, or maximum opening. These measurements should not be inferred from another manufacturer's Markham Meyerding retractor.
The current Peak Surgicals specification confirms German stainless steel construction. The rigid metallic structure is appropriate for a reusable surgical retractor subjected to controlled mechanical loading during spinal procedures.
The exact stainless-steel alloy grade is not stated on the current page. Hospitals, spine centers, distributors, and procurement teams requiring a specific material designation or certificate should confirm that specification before ordering.
Peak Surgicals specifically lists the Markham Meyerding Hemilaminectomy Retractor as reusable. The instrument should be cleaned, inspected, and reprocessed according to applicable manufacturer instructions and the healthcare facility's validated procedures.
Before reuse, the blade, sharp tenaculum, joints, locking components, and other working surfaces should be inspected for corrosion, deformation, misalignment, restricted movement, or visible mechanical damage.
The current Peak Surgicals product specification lists satin, dull, and mirror finish options. Buyers can select the required surface finish according to their purchasing specification or existing surgical instrument inventory.
The selected finish should be confirmed at the time of ordering if a particular surface treatment is required.
| Product Name | Markham Meyerding Hemilaminectomy Retractor |
| Main Storefront SKU | PS-OT-0985 |
| Instrument Type | Hemilaminectomy Retractor |
| Pattern | Markham Meyerding |
| PS-8754 Configuration | Blade on Right, Sharp Tenaculum on Left |
| PS-8753 Configuration | Blade on Left, Sharp Tenaculum on Right |
| Material | German Stainless Steel |
| Feature | Reusable |
| Finish Options | Satin, Dull, Mirror |
| Primary Surgical Context | Spinal / Hemilaminectomy Procedures |
| Listed Usage | Operating Room, Others |
| Exact Overall Length | Not Specified on Current Peak Surgicals Page |
| Blade / Tenaculum Dimensions | Not Specified on Current Peak Surgicals Page |
| Maximum Opening | Not Specified on Current Peak Surgicals Page |
The Markham Meyerding Hemilaminectomy Retractor is relevant for spine surgery departments, neurosurgical services, orthopedic spine centers, hospitals, surgical instrument distributors, and procurement teams sourcing specialized hemilaminectomy retractors.
For accurate purchasing, buyers should reference main SKU PS-OT-0985 together with the required working-end orientation: PS-8754 blade right / sharp tenaculum left or PS-8753 blade left / sharp tenaculum right. Buyers requiring exact overall length, blade dimensions, tenaculum dimensions, maximum opening, locking-mechanism specifications, or stainless-steel alloy grade should confirm those details before ordering.
It is a specialized surgical retractor pattern used for maintaining exposure during hemilaminectomy and related spinal procedures.
The current Peak Surgicals listing provides PS-8754 with blade on right and sharp tenaculum on left, and PS-8753 with blade on left and sharp tenaculum on right.
The current Peak Surgicals specification lists German stainless steel. The exact alloy grade is not stated.
Yes. Peak Surgicals specifically lists the product as reusable.
The current storefront SKU is PS-OT-0985. PS-8753 and PS-8754 are the two listed working-end configuration codes.
The current Peak Surgicals page does not state an exact overall length, blade dimensions, tenaculum dimensions, or maximum opening for PS-OT-0985, so these should be confirmed before ordering if required.