Ringent Pin to Rod Coupling

The Ringent Pin to Rod Coupling is an orthopedic external fixation component designed to connect fixation pins with connecting rods during external fixator frame assembly. It is available in two configurations: Ø8 x 4.5 under code PS3803 and Ø11 x 5–6 under code PS3823. The product page identifies the complete product with SKU PS-OP-5919.

Pin-to-rod couplings form part of an external fixation system by creating a mechanical connection between a fixation pin and a supporting rod. This connection allows the pin to be incorporated into the external frame while the rod provides the structural pathway linking fixation components outside the limb. The selected coupling size should correspond to the pin and rod dimensions used within the chosen external fixation system.

Design and Function

The Ringent Pin to Rod Coupling is available in two dimensional configurations to support different external fixation setups. The Ø8 x 4.5 configuration is identified by code PS3803, while the Ø11 x 5–6 configuration is identified by code PS3823. These size combinations indicate the coupling relationship between the rod diameter and compatible pin diameter within the external fixation assembly.

The coupling functions as an interface between two separate components of the frame. One side accommodates the connecting rod while the other accommodates the fixation pin. Once positioned within the external fixator construct, the coupling allows the surgeon to organize the relationship between the pin and rod according to the selected frame configuration.

Because external fixation systems can use different rod and pin diameters, correct size selection is essential when ordering replacement components or assembling a complete system. The Ø8 x 4.5 and Ø11 x 5–6 options should therefore be identified by their full dimensions rather than by the generic product name alone.

Available Sizes

Two Ringent Pin to Rod Coupling configurations are available. The smaller configuration is Ø8 x 4.5 and carries code PS3803. The larger configuration is Ø11 x 5–6 and carries code PS3823. Both belong to the same Ringent Pin to Rod Coupling product family.

The live product page displays a product price of $55.00 USD. The correct code and dimensional configuration should be confirmed before ordering so the coupling matches the external fixation components used in the surgical system.

Orthopedic Application

Ringent Pin to Rod Couplings are used within orthopedic external fixation systems. External fixation constructs use fixation pins and external connecting rods to create a frame outside the body. A pin-to-rod coupling provides the connection point that brings these components together within that frame.

The coupling is therefore selected as part of the overall external fixation configuration rather than as a stand-alone general orthopedic instrument. The required size depends on the rod and fixation pin dimensions used in the system. Peak Surgicals also lists these coupling sizes within its external fixator instrument range, where pin-to-rod, rod-to-rod, and related coupling components are used together to assemble external fixation frames.

Hospitals, orthopedic departments, trauma centers, and surgical instrument distributors can use the individual product codes to identify replacement or additional coupling components for compatible external fixation setups. Maintaining the correct dimensional designation in purchasing and inventory records helps distinguish the Ø8 x 4.5 configuration from the Ø11 x 5–6 configuration.

Product Specifications

Product Name Ringent Pin to Rod Coupling
Product SKU PS-OP-5919
Component Type Pin to Rod Coupling
Configuration 1 PS3803 — Ø8 x 4.5
Configuration 2 PS3823 — Ø11 x 5–6
Product Price $55.00 USD
Application Orthopedic External Fixation Systems
Brand Peak Surgicals

Care and Handling

The coupling should be inspected before use as part of the complete external fixation system. Check the component for visible damage, deformation, contamination, or other conditions that could interfere with correct assembly. Particular attention should be given to the areas that engage the fixation pin and connecting rod.

Cleaning, preparation, handling, and processing should follow the current instructions supplied for the external fixation system and the healthcare facility's validated procedures. Generic processing temperatures, exposure times, or sterilization cycles should not be substituted for product-specific instructions.

Ordering

When ordering the Ringent Pin to Rod Coupling, confirm the required configuration before purchase. Select PS3803 for Ø8 x 4.5 or PS3823 for Ø11 x 5–6. The product is listed under SKU PS-OP-5919 and is currently displayed at $55.00 USD.

For related frame components and orthopedic fixation products, browse the External Fixators collection.

Frequently Asked Questions

What is the Ringent Pin to Rod Coupling used for?

It connects a fixation pin to a connecting rod within an orthopedic external fixation system.

What sizes are available?

The available configurations are Ø8 x 4.5 and Ø11 x 5–6.

What is the code for the Ø8 x 4.5 coupling?

The code is PS3803.

What is the code for the Ø11 x 5–6 coupling?

The code is PS3823.

What is the main product SKU?

The product SKU is PS-OP-5919.

Is this component part of an external fixation system?

Yes. It is a pin-to-rod connection component used within orthopedic external fixation frame assemblies.