Skip to product information
1 of 3

PEAK SURGICAL

Mayo Hegar Needle Holder 6" (152mm)

Mayo Hegar Needle Holder 6" (152mm)

1 total reviews

SKU:PS-P-00017

Regular price $27.50 USD
Regular price Sale price $27.50 USD
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Secure Checkout Protected payment flow
Quality Inspected Checked before dispatch
Worldwide Supply International buyer support
Shipping, Returns & Payments Clear buyer information before checkout.
Shipping
Free shipping on orders over $99. See shipping details
Returns
Returns and exchanges are handled according to our return policy. See return policy
Payments
American Express Apple Pay Diners Club Discover Google Pay JCB Mastercard
View full details

The Mayo Hegar Needle Holder 6" (152mm) from Peak Surgicals (SKU: PS-P-00017) is a reusable stainless steel surgical instrument designed to hold and guide suture needles during tissue closure. Its straight serrated jaws, box joint, finger-ring handles, and ratchet locking mechanism provide a familiar hand-operated configuration for controlled needle handling. The 6-inch length offers a balanced working profile for general surgical suturing, post-mortem closure, pathology procedures, anatomy laboratories, veterinary applications, and other professional settings where secure needle engagement is required. This instrument is intended for use by trained professionals under the applicable clinical, laboratory, or facility protocol.

Straight Serrated Jaws, Box Joint, Ring Handles, and Ratchet Lock

The straight jaws provide a direct approach to the suture needle and help the operator maintain a consistent working angle during closure. Serrations on the inner jaw surfaces increase contact with the needle and support controlled positioning as the needle is guided through tissue. The jaws are narrow enough for focused needle engagement while retaining the Mayo-Hegar pattern commonly selected for routine suturing applications.

A box joint connects the two instrument halves and helps maintain jaw alignment throughout opening and closing. Correct alignment is important because both jaw surfaces must meet evenly to hold the needle without unnecessary movement. The joint should be inspected regularly for smooth action, debris, looseness, or resistance that could affect instrument performance.

Finger-ring handles provide a conventional surgical grip and allow the user to open, close, and reposition the instrument with one hand. The interlocking ratchet mechanism maintains the selected jaw position after the handles are closed. Multiple locking positions allow the user to select an appropriate level of engagement according to the needle, procedure, and professional technique.

Six-Inch Mayo-Hegar Pattern for Surgical and Post-Mortem Suturing

The 6" (152mm) size combines working reach with a compact handle profile. It is suited to routine closure tasks where a longer needle holder is not required. The straight working end supports direct visualization of the jaws and suture needle, while the ring-handle configuration provides familiar manual control for trained users.

In surgical settings, the Mayo Hegar needle holder may be incorporated into instrument sets prepared for general tissue closure and related suturing procedures. In post-mortem and pathology settings, it can support external closure and reconstruction work performed after examination. It may also be included in veterinary, training, anatomy-laboratory, and institutional instrument sets where a reusable manual needle driver is required.

This instrument is designed to hold and guide a suture needle. It is not intended to replace surgical scissors, tissue forceps, hemostatic forceps, or other instruments with different functions. Selecting the correct needle holder, needle type, and suture material remains the responsibility of the trained professional performing the procedure.

Controlled Needle Handling and Instrument Inspection

Before use, the jaws should be inspected for alignment, surface damage, contamination, and consistent closure. The box joint should move smoothly, and each ratchet position should engage and release correctly. The finger rings and shanks should also be checked for cracks, distortion, corrosion, or other visible damage.

During professional use, the suture needle is positioned between the serrated jaw surfaces and secured using an appropriate ratchet position. The straight jaws help maintain visual orientation as the needle is guided and repositioned. Excessive locking pressure should be avoided because the required level of engagement depends on the needle and procedure.

After the procedure, the ratchet should be released before cleaning so the jaws and joint remain accessible. The instrument should not be stored in a locked position. Routine inspection and correct handling help preserve jaw alignment, joint movement, ratchet engagement, and overall serviceability.

German-Forged Stainless Steel Construction and Reprocessing

The Mayo Hegar Needle Holder is manufactured from German-forged stainless steel for the strength, rigidity, and corrosion resistance expected from a reusable professional instrument. The stainless steel construction supports repeated handling and facility-controlled reprocessing when the instrument is cleaned, inspected, sterilized, and stored according to the applicable validated protocol.

Visible soil should be removed promptly after use, with particular attention given to the serrated jaws, box joint, ratchet teeth, and finger-ring areas. The instrument should be processed in an open position so cleaning agents can reach the contacting surfaces. After cleaning, it should be thoroughly inspected and dried before proceeding with the facility-approved sterilization process.

Peak Surgicals operates under medical-device quality-management requirements and supports professional, institutional, distributor, and international procurement. Buyers requiring ISO 13485, CE, FDA, tender, or destination-market documentation should confirm the documents applicable to this product and intended market before ordering.

SKU PS-P-00017
Product Name Mayo Hegar Needle Holder
Current Price $27.50 USD per piece
Size 6" (152mm)
Instrument Category Needle Holders
Pattern Mayo-Hegar
Primary Function Holding and guiding suture needles during professional tissue closure
Common Settings General surgery, post-mortem closure, pathology, veterinary procedures, anatomy laboratories, and professional training
Jaw Shape Straight
Jaw Surface Serrated
Joint Box joint
Handle Finger-ring handles
Locking Mechanism Interlocking ratchet
Material German-forged stainless steel
Reusable Yes, subject to validated cleaning, inspection, and sterilization procedures
Quantity One instrument
Brand Peak Surgicals

What is a Mayo Hegar Needle Holder used for?

A Mayo Hegar needle holder is used to grasp, control, and guide a suture needle during tissue closure. Its ring handles and ratchet lock allow the user to maintain jaw engagement while directing or repositioning the needle. The instrument is commonly incorporated into general surgical, post-mortem, pathology, veterinary, and professional training sets.

What are the main features of this 6-inch model?

This model has straight serrated jaws, a box joint, finger-ring handles, and a ratchet locking mechanism. Its overall length is 6" (152mm). These features create a compact Mayo-Hegar configuration for routine professional suturing and closure applications.

Can this needle holder be used for post-mortem closure?

Yes. The instrument can support professional post-mortem closure and reconstruction procedures in pathology and mortuary settings. It may be included with other post-mortem instruments selected according to the facility’s closure technique, suture material, and established operating procedure.

Is the Mayo Hegar Needle Holder reusable?

Yes. It is a reusable stainless steel instrument when correctly cleaned, inspected, sterilized, and stored. The exact reprocessing method and sterilization parameters should follow the validated protocol and instructions applicable to the purchasing facility.

What should be inspected before using the instrument?

Users should confirm that the jaws meet evenly, the serrations are undamaged, the box joint moves smoothly, and the ratchet engages and releases correctly. An instrument showing corrosion, cracks, distortion, loose movement, damaged jaws, or unreliable ratchet engagement should be removed from service and evaluated under the facility’s instrument-management procedure.