Skip to product information
1 of 3

PEAK SURGICALS

Mini Hand Drill for Controlled Mini-Fragment Fixation and Small-Bone Drilling

Mini Hand Drill for Controlled Mini-Fragment Fixation and Small-Bone Drilling

1 total reviews

SKU:PS-OP-58290

Regular price $177.09 USD
Regular price Sale price $177.09 USD
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Secure Checkout Protected payment flow
Quality Inspected Checked before dispatch
Worldwide Supply International buyer support
Shipping, Returns & Payments Clear buyer information before checkout.
Shipping
Free shipping on orders over $99. See shipping details
Returns
Returns and exchanges are handled according to our return policy. See return policy
Payments
American Express Apple Pay Diners Club Discover Google Pay JCB Mastercard
View full details

Mini Hand Drill, SKU PS-OP-5829 and catalog model PS-311.033, is a compact manually operated orthopedic drill manufactured from German stainless steel for bone-channel preparation during mini-fragment fixation. Its reduced handpiece format is suited to controlled drilling in exposed small bones where the surgeon requires direct tactile feedback and deliberate rotational advancement. The instrument is used during fracture fixation of the phalanges, metacarpals, selected carpal structures, metatarsals, and other small osseous sites treated with mini-fragment plates and screws. The supporting grip stabilizes the drilling axis while the manual drive rotates the bit secured at the distal end. During plate osteosynthesis, the drill is paired with the drill bit and guide specified for the selected screw system. The operative sequence includes fracture reduction, temporary stabilization, plate positioning, guided pilot-hole preparation, depth measurement, tapping when required, and screw insertion. The Mini Hand Drill is relevant to orthopedic trauma surgeons, hand surgeons, foot and ankle surgeons, veterinary orthopedic specialists, and operating-room teams in hospitals, ambulatory surgical centers, trauma units, and specialty clinics. Drill bits, guides, depth gauges, taps, plates, screws, adapters, keys, and storage trays are separate unless expressly included in the order.

Compact Manual Drive and Axial Instrument Control

The Mini Hand Drill converts hand-generated movement into controlled rotation of a retained orthopedic drill bit. Its compact frame reduces the bulk surrounding the operative field and supports instrument positioning over small plates, short bone segments, and limited surgical exposures. The surgeon stabilizes the body or support grip with one hand while operating the rotating drive with the other. This two-handed technique separates rotational movement from axial guidance, allowing the drill to remain aligned with the selected plate hole or drill guide. The distal retention mechanism holds the bit along the instrument’s rotational axis and transfers manual force to its cutting flutes. A correctly matched guide controls entry position, supports the planned screw trajectory, and separates the rotating shaft from adjacent tendons, neurovascular structures, and soft tissue. Manual operation provides tactile information as the drill passes through cortical bone and enters the cancellous compartment. The operator can regulate rotation and advancement without relying on a battery, electrical cable, pneumatic hose, or powered console. Before use, the handpiece, rotating mechanism, bit-retention area, shaft alignment, and handle junctions must be examined for secure engagement and smooth movement. Chuck slippage, eccentric rotation, corrosion, deformation, or mechanical binding requires removal from the operative set.

Mini-Fragment Fixation and Small-Bone Workflow

The Mini Hand Drill is positioned within mini-fragment fixation workflows where screw trajectory and limited drilling depth require close manual control. During phalangeal or metacarpal fracture fixation, the fragments are reduced and stabilized before a corresponding mini plate is contoured and positioned. The surgeon introduces a matching guide through the selected plate hole and seats it against the cortex. A system-specific bit is secured in the drill, passed through the guide, and advanced manually along the planned axis. For a threaded pilot hole, the diameter corresponds to the screw core; a gliding hole used for interfragmentary compression follows the dimensions specified by the fixation system. The drilled channel is measured with a mini depth gauge, tapped when the screw design requires thread preparation, and completed with the selected implant. Comparable principles apply to suitable metatarsal, small-foot, or veterinary small-bone repairs. The compact instrument supports access between retractors and fixation components but does not determine the correct bit, screw, or channel depth. The surgeon must protect extensor and flexor tendons, digital neurovascular bundles, joint surfaces, and the far cortex throughout drilling. Unicortical or bicortical preparation is selected according to fracture morphology, plate design, bone stock, and the approved implant technique.

Model Configuration and Mini-Fragment Component Selection

Catalog model PS-311.033 identifies the Mini Hand Drill, while PS-OP-5829 is the Shopify inventory SKU displayed on the product page. This listing presents one handpiece configuration and does not show separate drill sizes or gauge variants. Clinical selection therefore depends on the fixation system used with the instrument. Mini-fragment systems commonly include dedicated drill bits, sleeves, neutral or load guides, depth gauges, taps, screwdrivers, plates, and cortical screws. A 1.5 mm cortical screw system can use different pilot and gliding-hole dimensions from a 2.0 mm construct, so each component must follow the implant manufacturer’s operative technique. The guide bore must correspond to the selected bit and seat securely in the plate hole or against the exposed cortex. The bit must remain concentric within the Mini Hand Drill retention mechanism to prevent eccentric rotation and loss of trajectory. Pilot-hole depth is controlled according to the selected screw length and whether unicortical or bicortical purchase is intended. A depth gauge is used after drilling rather than estimating length from the exposed bit. The hand drill is the rotational driver only; compatibility with a specific bit connection or implant platform must be established from the ordered configuration and supporting product documentation.

German Stainless Steel, Reprocessing, and Procurement Records

The Mini Hand Drill is manufactured from German stainless steel for repeated use as a manual orthopedic drilling instrument. Stainless-steel construction provides the rigidity required to transfer rotational and axial force while supporting inspection and validated reprocessing between procedures. Accessible metallic surfaces should be examined for retained soil, corrosion, staining, pitting, deformation, and wear around the rotating assembly, bit-retention area, handle junctions, and recessed interfaces. After use, the instrument must be cleaned, rinsed, dried, inspected, function-tested, packaged, and sterilized according to the manufacturer’s instructions and the healthcare facility’s validated protocol. Reprocessing personnel should operate accessible moving components during cleaning when authorized by the instructions so that contacting surfaces receive adequate treatment. Before packaging, the drill must rotate smoothly and retain the selected bit without slippage or lateral play. Peak Surgicals supports CE and ISO 13485 documentation for hospital and distributor procurement assessment. FDA establishment registration, device listing, clearance, and approval are separate regulatory concepts; FDA-related language must correspond to the documentation applicable to the product and destination market. Procurement teams should retain the SKU, catalog model, invoice, batch information, declarations, reprocessing instructions, and after-sale records within their institutional quality-management system.

SKU PS-OP-58290
Product Name Mini Hand Drill
Price $177.09 USD
Size/Gauge Variants Single handpiece configuration; catalog model PS-311.033
Instrument Category Mini-fragment orthopedic hand drill
Procedure Small-bone pilot-hole preparation during mini-fragment plate-and-screw fixation
Material German stainless steel
Finish Metallic surgical instrument finish
Sterilization Reprocess according to the manufacturer’s instructions and the facility’s validated sterilization protocol
Instrument Classification Reusable manual orthopedic surgical instrument
Reusable Yes
Certifications CE and ISO 13485 procurement documentation; FDA-related records supplied according to applicable market requirements
Warranty 30-day money-back guarantee under the published store policy
MOQ One instrument for standard online orders
OEM / Custom Orders OEM, private-label, and institutional requirements are handled through a written quotation
After-Sale Service Order, documentation, and product-support assistance through Peak Surgicals customer service

How does the Mini Hand Drill differ from the Universal Bone Drill?
The Mini Hand Drill is configured for compact handling within mini-fragment and small-bone fixation workflows. The Universal Bone Drill is a larger manual pattern with a closed geared transmission intended for broader orthopedic drilling requirements. The mini configuration occupies less working space around short bone segments and small fixation plates. Its procedural selection commonly centers on phalangeal, metacarpal, or comparable small-bone constructs. Both instruments require a compatible drill bit, guide, depth gauge, and fixation system. The choice depends on the target bone, exposure, implant platform, required bit connection, and surgeon’s handling preference.

How should drill-bit size be selected for mini-fragment fixation?
The bit is selected according to the screw diameter and the implant manufacturer’s operative technique. A threaded pilot hole corresponds to the screw core, while a gliding hole used for interfragmentary compression follows a different specified diameter. Systems using 1.5 mm and 2.0 mm cortical screws do not automatically share the same drill-bit dimensions. The guide bore must match the chosen bit and plate hole. The bit must seat concentrically within the Mini Hand Drill without slipping or lateral movement. Final screw length is determined with a compatible depth gauge after the channel has been prepared.

What do CE, ISO 13485, and FDA references mean for this instrument?
CE documentation supports procurement assessment against applicable European medical-device requirements. ISO 13485 relates to the manufacturer’s medical-device quality-management system. Neither statement is equivalent to an FDA product approval. FDA establishment registration, device listing, clearance, and approval carry distinct regulatory meanings. The Mini Hand Drill should be described using the exact documentation applicable to its device classification and destination market. Hospitals and distributors can request available commercial and regulatory records before approving the purchase.

How is the manual rotating mechanism controlled intraoperatively?
The surgeon stabilizes the Mini Hand Drill with one hand and operates its rotating drive with the other. The supporting hand maintains alignment with the drill guide and planned screw axis. The driving hand regulates rotational speed and axial advancement as the bit engages the cortex. Pressure is applied in line with the guide rather than laterally against the bit. Tactile changes help the operator recognize transitions between cortical and cancellous bone. Before drilling, the rotating assembly and retention mechanism must be checked for smooth movement, concentric alignment, and secure bit engagement.

What should an operating-room team assess before purchasing and sterilizing the drill?
The team should confirm SKU PS-OP-5829, catalog model PS-311.033, required quantity, and compatibility with the intended mini-fragment system. The facility must obtain the applicable cleaning and sterilization instructions before clinical use. Reprocessing personnel should inspect the rotating components, bit-retention area, handle junctions, and recesses for retained material or damage. The Mini Hand Drill requires functional testing before packaging for the validated sterilization cycle. Drill bits, guides, depth gauges, taps, screws, and storage equipment should be ordered separately unless the quotation lists them. Procurement and reprocessing records should retain the model, batch, invoice, regulatory documentation, maintenance history, and service correspondence.