Skip to content
Couldn't load pickup availability
Secured Checkout Guaranteed.
30 Day's Money Back Guaranteed.
Free Shipping on Orders Above 99 $.

Lincoln Dissecting Scissors, SKU PS-OT-0950, are reusable surgical dissecting scissors manufactured from German stainless steel for controlled deep soft-tissue dissection, fascia trimming, fibrous band division, mucosal edge refinement, and operative field adjustment in open surgical procedures. The available variants are PS-2673 Curved with 7" (17.8 cm) overall length, PS-2674 Curved with 11" (27.9 cm) overall length, and PS-2672 Straight with 7" (17.8 cm) overall length. The image shows long straight blades, a screw-joint pivot, elongated shanks, and ring handles designed for fingertip closure in operating room workflow. General surgeons, plastic surgeons, ENT surgeons, gynecology teams, oral and maxillofacial surgeons, orthopedic teams, veterinary surgeons, and operating room staff use this pattern during soft-tissue dissection, superficial fascial division, wound-edge refinement, biopsy margin adjustment, scar revision, mucosal trimming, suture cutting, superficial adhesiolysis, flap contouring, and closure-stage tissue management in hospitals, clinics, ambulatory surgical units, dental operating rooms, veterinary theaters, and reusable surgical trays.
The instrument works through two opposing blades joined by a screw-joint pivot that converts ring-handle compression into controlled distal closure. The straight blade pattern supports direct cutting when the surgeon needs a linear path through visible tissue, suture, fascia edge, or superficial fibrous strand. The curved versions allow the lower blade to pass beneath an elevated tissue plane while the upper blade completes the cut from an oblique angle. Long shanks move the operator’s hand away from retractors, suction tips, hemostats, forceps, and assistant instruments, improving clearance in open fields. Ring handles provide thumb and ring-finger purchase, while the index finger can rest along the shank for directional control. The screw joint keeps the blades aligned so the cutting edges meet evenly during closure. There is no ratchet, spring, or locking catch, so every cut depends on fingertip pressure, tissue traction, blade position, and direct visual confirmation. This mechanism is appropriate for progressive dissection and trimming rather than heavy bone, cartilage, or dense instrument-resistant material.
During general surgery, the scissors can assist after scalpel entry by dividing superficial soft tissue, refining fascial edges, trimming nonvascular strands, and adjusting wound margins before closure. In plastic surgery, the curved patterns support scar revision, skin-flap contouring, undermined edge trimming, and fine correction after tissue elevation with forceps. ENT teams can use the shorter curved variant around mucosal margins, tonsillar pillar remnants, nasal soft tissue, and oropharyngeal access where a straight approach would crowd the field. In oral and maxillofacial procedures, the instrument supports mucosal flap refinement, biopsy margin trimming, gingival soft-tissue correction, and closure-stage suture management. Gynecology and orthopedic teams can use the straight model for visible surface cutting and the longer curved model when reach across a deeper wound corridor is required. Veterinary surgeons can place the same pattern in soft-tissue sets for small and large animal procedures. The cutting step is performed after the intended plane is exposed, stabilized, and separated from vessels, nerves, ducts, or deeper structures not selected for division.
PS-2672 Straight with 7" (17.8 cm) overall length is selected when the target tissue is visible and aligned with the shaft, such as suture trimming, superficial fascia adjustment, skin-edge refinement, biopsy margin correction, or direct soft-tissue cutting. PS-2673 Curved with 7" (17.8 cm) overall length is selected when the surgeon needs a compact curved approach under a lifted tissue edge, mucosal margin, scar strand, or flap plane. PS-2674 Curved with 11" (27.9 cm) overall length is selected for deeper operative corridors where hand clearance is required around retractors, suction, clamps, packs, or assistant instruments. The 11" pattern provides extended reach while preserving curved blade orientation for controlled dissection. Selection depends on exposure depth, tissue plane, patient habitus, access route, and whether the cut is made in a direct line or beneath an elevated structure. Stocking all three variants gives surgical teams short straight, short curved, and extended curved options within the Lincoln Dissecting Scissors pattern.
German stainless steel supports the mechanical requirements of dissecting scissors by maintaining blade alignment, corrosion resistance, and smooth pivot movement through repeated cleaning and steam sterilization cycles. Satin, dull, and mirror finish options allow procurement teams to match surface preference with glare control, visual inspection, and existing operating room tray standards. After use, the blades should be opened and cleared of blood, tissue residue, suture fragments, lint, and dressing fibers before enzymatic cleaning. Processing can include manual brushing, ultrasonic decontamination, washer-disinfector exposure, rinsing, drying, pivot inspection, edge review, packaging, and steam autoclave sterilization according to facility protocol. The screw joint requires careful attention because retained debris can change closure resistance and reduce distal cutting accuracy. CE marking, ISO 13485 documentation, and FDA procurement context support purchasing records for hospitals, clinics, distributors, surgical centers, dental units, veterinary facilities, and teaching programs. Class I classification, reusable construction, carton-box packing, 1-piece MOQ, OEM availability, 1-year warranty, and return and replacement support assist replacement ordering and distributor supply.
| SKU | PS-OT-0950 |
|---|---|
| Product Name | Lincoln Dissecting Scissors |
| Price | $7.15 |
| Size/Gauge Variants | PS-2673 Curved, overall length 7" (17.8 cm); PS-2674 Curved, overall length 11" (27.9 cm); PS-2672 Straight, overall length 7" (17.8 cm) |
| Instrument Category | Reusable surgical dissecting scissors |
| Procedure | Soft-tissue dissection, superficial fascial division, wound-edge refinement, biopsy margin adjustment, scar revision, mucosal trimming, suture cutting, superficial adhesiolysis, flap contouring, closure-stage tissue management |
| Material | German stainless steel |
| Finish | Satin, dull, or mirror finish |
| Sterilization | Reusable instrument suitable for enzymatic cleaning, ultrasonic decontamination, washer-disinfector processing, drying, pivot inspection, packaging, and steam autoclave sterilization |
| Instrument Classification | Class I reusable surgical instrument |
| Reusable | Yes |
| Certifications | CE, ISO 13485, FDA |
| Warranty | 1 year |
| MOQ | 1 piece |
| OEM / Custom Orders | Available for distributor supply, institutional branding, bulk purchasing, and customized packing programs |
| After-Sale Service | Return and replacement support for eligible orders |
How are Lincoln Dissecting Scissors different from Metzenbaum scissors?
Metzenbaum scissors are the closest alternative because they are widely used for delicate soft-tissue dissection. Lincoln Dissecting Scissors provide straight and curved variants with 7" and 11" working lengths for broader reach selection. The straight Lincoln pattern supports direct surface cutting, while the curved versions support access beneath elevated tissue. Metzenbaum scissors are often selected for routine delicate dissection, while Lincoln Dissecting Scissors are useful when the operating team wants a longer named dissecting pattern with extended reach options. Both instruments use ring handles and a screw-joint pivot. The clinically relevant difference is variant range, working length, blade approach, and tray designation.
How should the 7 inch and 11 inch variants be selected?
The 7" straight PS-2672 variant is selected for direct cutting on visible tissue, fascia edge, suture material, or superficial wound margins. The 7" curved PS-2673 option is selected when the surgeon needs a compact curved blade to pass beneath lifted tissue or follow a shallow contour. The 11" curved PS-2674 variant is selected for deeper wound corridors where the hand must remain clear of retractors, suction, packs, or assistant instruments. Lincoln Dissecting Scissors should be selected according to exposure depth, tissue plane, access angle, and whether the target is flat or elevated. The straight model provides direct-line control, while the curved models provide side-entry access. Stocking all three variants supports general surgery, plastic surgery, ENT, gynecology, oral surgery, and veterinary soft-tissue trays.
What do CE, ISO 13485, and FDA details mean for procurement?
CE documentation supports international conformity records for reusable surgical instrument purchasing. ISO 13485 indicates manufacturing under a medical device quality management system covering production control, inspection, and traceability. FDA procurement context supports U.S. purchasing files for Class I reusable surgical scissors. Lincoln Dissecting Scissors can be entered into hospital, clinic, distributor, dental, veterinary, and operating room catalogs with documented material, finish, model selections, warranty, MOQ, OEM availability, and after-sale service. These records help purchasing officers, receiving teams, and sterile processing departments align the item with internal approval requirements. The certification profile supports tender files, replacement stock, and standardized surgical tray programs.
How does the screw-joint pivot control cutting during dissection?
The screw-joint pivot is the main control feature because it transfers ring-handle pressure into blade closure. The operator places the thumb and ring finger in the handles while using the index finger along the shank to guide the distal blades. As the handles close, the cutting edges meet at the selected tissue margin, fascia edge, fibrous strand, suture, or mucosal fold. The pivot keeps the blades aligned without a ratchet, spring, or locking catch. Lincoln Dissecting Scissors rely on fingertip pressure, forceps stabilization, blade orientation, and direct visualization rather than mechanical locking. Cleaning around the pivot is important because dried blood, tissue residue, or lint can alter resistance and reduce smooth closure.
Are these scissors suitable for reusable sterile processing and distributor stock?
Yes, Lincoln Dissecting Scissors are reusable German stainless steel instruments suitable for hospital, clinic, distributor, dental, veterinary, and operating room supply workflows. After use, the blades and screw joint should be opened so blood, tissue residue, suture fragments, lint, and dressing fibers can be removed before sterilization. Processing can include enzymatic cleaning, ultrasonic decontamination, washer-disinfector exposure, drying, pivot inspection, packaging, and steam autoclaving. The 1-piece MOQ supports replacement ordering for clinics, procedure rooms, specialty trays, and surgical centers. OEM availability supports distributor branding, institutional packing, and bulk purchasing programs. The 1-year warranty and return and replacement service support procurement teams managing recurring dissecting-scissor inventory.
Order Processing: We strive to serve you promptly! Orders placed before the cut-off time of 5:00 PM (GMT -05:00) (Eastern Standard Time) will be processed the same business day. Orders placed after this time will be processed the next business day.
Handling Time: Our standard handling time is 1-2 business days (Monday through Friday). This includes order verification, quality checks, packaging, and dispatch. Please note that orders placed on weekends or holidays will be processed on the following business day.
Transit Time: Once dispatched, the estimated transit time is 4-5 business days (Monday through Friday). However, transit times may vary depending on your location and any unforeseen circumstances.
Shipping Fee: Enjoy free worldwide shipping on all orders over $250! At Peak Surgical Instruments, we cover all import charges for your convenience.
Customers will receive a tracking ID as soon as their order is dispatched via FedEx or DHL.
We proudly offer worldwide shipping, ensuring that our premium surgical instruments are accessible to healthcare professionals across the globe. No matter where you are, you can count on us to deliver quality tools right to your doorstep!
To provide you with confidence in your purchase, we offer a 1-year warranty as well as a 30-day money-back guarantee on all non-personalized orders.
We understand that delays can be frustrating. Transit times are estimates based on recent orders and may change. If your package is delayed, we will do everything possible to expedite delivery. In case of significant delays or missing packages, we will reship your order at no extra cost to you.
At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.
To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.
Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.
To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.
Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States
No Restocking Fee: We do not charge restocking fees on approved returns.
Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.
Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.
Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.
Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.
Please note that your bank or credit card provider may require additional time to post the refund to your account.
Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.
Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.
For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.
Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.
For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.
For return, refund, or exchange inquiries, please contact us:
Phone: +1 315 526 9968
Email: info@peaksurgicals.com