<p>Jones Dissecting Scissors, SKU PS-2663, are reusable surgical scissors manufactured from German stainless steel for controlled tissue dissection, fine soft-tissue cutting, suture trimming, and operative field refinement in general surgical...
In stock
Price:
$5.72
  • Secure Checkout

    Secured Checkout Guaranteed.

  • 30 Day's Money Back

    30 Day's Money Back Guaranteed.

  • Free Shipping On 99 $

    Free Shipping on Orders Above 99 $.

Jones Dissecting Scissors
Regular price $5.72
Regular price Sale price $5.72 (-0%)
Size: 5-1/2" (14 cm) Curved
Jones Dissecting Scissors
Jones Dissecting Scissors
$5.72

<p>Jones Dissecting Scissors, SKU PS-2663, are reusable surgical scissors manufactured from German stainless steel for controlled tissue dissection, fine soft-tissue cutting, suture trimming, and operative field refinement in general surgical and specialty procedures. The available variants are 5-1/2" (14 cm) Curved and 5-1/2" (14 cm) Straight, giving the operator a curved profile for elevated tissue planes and a direct-line pattern for exposed surface cutting. The image shows slender pointed blades, a screw-joint pivot, slim shanks, and ring handles designed for fingertip closure. General surgeons, plastic surgeons, ENT surgeons, oral and maxillofacial surgeons, dermatologic surgeons, gynecology teams, veterinary clinicians, and operating room staff use this instrument during biopsy margin trimming, superficial adhesiolysis, skin-edge refinement, mucosal dissection, minor wound revision, suture removal, scar revision, flap contouring, dental soft-tissue work, and small animal surgery in hospitals, outpatient surgical units, dental operating rooms, emergency procedure rooms, teaching labs, and reusable minor surgery trays.</p>

<h2>Slender Blade Geometry and Screw-Joint Cutting Control</h2>
<p>The instrument works through two narrow blades connected by a screw-joint pivot that transfers ring-handle compression into controlled distal closure. The pointed blade profile allows the tip to enter compact soft-tissue planes where broader scissors would engage excess tissue or obstruct the field. In the straight version, the cutting edge follows the shaft axis, supporting linear trimming of exposed suture ends, superficial skin margins, biopsy edges, and fine dressing material. In the curved version, the distal profile allows the lower blade to pass beneath lifted mucosa, scar tissue, undermined skin, or a thin fibrous strand while the upper blade completes the cut from an oblique angle. Slim shanks keep the operator’s hand away from forceps, suction, retractors, and illumination. Ring handles provide thumb and ring-finger control, while the index finger can guide shaft direction. The screw joint maintains blade alignment during closure and requires smooth movement for accurate tip contact. There is no ratchet, spring, or locking catch, so each cut is controlled by finger pressure, tissue stabilization, and direct visualization.</p>

<h2>Minor Surgery, Dissection, and Closure Workflow</h2>
<p>During minor surgical procedures, the scissors support fine tissue separation after the plane has been exposed with forceps, a probe, or a small retractor. In skin lesion excision, the straight pattern can refine epidermal and dermal margins before closure, while the curved option follows an elevated edge during undermining or scar revision. In oral and maxillofacial work, the instrument can trim gingival tissue, mucosal flaps, frenectomy margins, and suture ends without using a heavier operating scissor. ENT teams can use the curved variant around nasal mucosa, auricular soft tissue, and tonsillar pillar remnants where a compact distal blade is required. Plastic surgery teams use this profile for flap contouring, thin fibrous strand division, and fine wound-edge adjustment. In gynecology and veterinary practice, the 14 cm length supports controlled trimming in shallow operative fields and small-patient soft-tissue procedures. The cutting stage is performed after the target tissue is stabilized, keeping sharp tips away from vessels, nerves, ducts, and deeper planes not intended for division.</p>

<h2>Straight and Curved 14cm Pattern Selection</h2>
<p>The 5-1/2" (14 cm) Straight variant is selected when the surgeon needs a direct blade path on tissue or material that is already visible and aligned with the instrument shaft. It is suited to suture removal, superficial tissue trimming, biopsy edge refinement, small wound revision, and linear cutting on exposed surfaces. The 5-1/2" (14 cm) Curved variant is selected when the tissue has been lifted or when the cut must follow a contour rather than a flat surface. This profile is useful around mucosal flaps, undermined skin, scar edges, nasal soft tissue, gingival margins, and thin adhesions. Both variants use the same ring-handle control and screw-joint action, so model selection depends on approach angle rather than handle mechanics. The 14 cm length gives compact control for outpatient procedure rooms, dental surgical trays, dermatologic setups, and minor operating room packs. Stocking both forms lets clinical teams cover direct surface cutting and side-entry dissection with one familiar Jones Dissecting Scissors pattern.</p>

<h2>Reusable Steel Processing and Procurement Records</h2>
<p>German stainless steel construction supports edge stability, corrosion resistance, and repeated sterile processing for a reusable surgical scissor used across clinic and operating room workflows. Satin, dull, and mirror finish options allow procurement teams to match tray preference with glare control, surface inspection, and existing instrument inventory. After use, the blades should be opened and cleared of blood, tissue residue, suture fragments, lint, and dressing fibers before enzymatic cleaning. Processing can include manual brushing, ultrasonic decontamination, washer-disinfector exposure, rinsing, drying, pivot inspection, edge review, packaging, and steam autoclave sterilization according to facility protocol. The screw joint needs careful inspection because retained debris can change closure resistance and reduce fine cutting accuracy at the tip. CE, ISO 13485, and FDA documentation support purchasing records for hospitals, clinics, distributors, dental units, veterinary facilities, and surgical training programs. Class I classification, reusable construction, carton-box packing, 1-piece MOQ, OEM availability, 1-year warranty, and return and replacement service support replacement ordering and distributor catalog supply.</p>

<table>
<tbody>
<tr><th>SKU</th><td>PS-2663</td></tr>
<tr><th>Product Name</th><td>Jones Dissecting Scissors</td></tr>
<tr><th>Price</th><td>$5.72</td></tr>
<tr><th>Size/Gauge Variants</th><td>5-1/2" (14 cm) Curved; 5-1/2" (14 cm) Straight</td></tr>
<tr><th>Instrument Category</th><td>Reusable surgical dissecting scissors</td></tr>
<tr><th>Procedure</th><td>Biopsy margin trimming, superficial adhesiolysis, skin-edge refinement, mucosal dissection, minor wound revision, suture removal, scar revision, flap contouring, dental soft-tissue work, small animal surgery</td></tr>
<tr><th>Material</th><td>German stainless steel</td></tr>
<tr><th>Finish</th><td>Satin, dull, or mirror finish</td></tr>
<tr><th>Sterilization</th><td>Reusable instrument suitable for enzymatic cleaning, ultrasonic decontamination, washer-disinfector processing, drying, pivot inspection, packaging, and steam autoclave sterilization</td></tr>
<tr><th>Instrument Classification</th><td>Class I reusable surgical instrument</td></tr>
<tr><th>Reusable</th><td>Yes</td></tr>
<tr><th>Certifications</th><td>CE, ISO 13485, FDA</td></tr>
<tr><th>Warranty</th><td>1 year</td></tr>
<tr><th>MOQ</th><td>1 piece</td></tr>
<tr><th>OEM / Custom Orders</th><td>Available for distributor supply, institutional branding, bulk purchasing, and customized packing programs</td></tr>
<tr><th>After-Sale Service</th><td>Return and replacement support for eligible orders</td></tr>
</tbody>
</table>

<p><strong>How are Jones Dissecting Scissors different from Fine Scissors?</strong><br>Fine Scissors are a general compact cutting pattern used for delicate trimming across many procedure trays. Jones Dissecting Scissors are selected when the operator wants a named dissecting pattern with 14 cm straight and curved options for controlled tissue separation and edge refinement. Both patterns use narrow blades, ring handles, and a screw-joint pivot. The Jones pattern fits minor surgery, plastic surgery, oral surgery, ENT, dermatology, and veterinary tray setups where delicate dissection and precise trimming are required. The clinically relevant difference is tray designation, blade selection, and the intended role as a dissecting scissor rather than a general fine cutting instrument. Jones Dissecting Scissors are appropriate when procurement teams need a reusable named pattern for delicate operative handling.</p>

<p><strong>How should the straight and curved 14 cm variants be selected?</strong><br>The straight 5-1/2" (14 cm) variant is selected when the cutting line is visible, superficial, and aligned with the shaft. It is useful for suture removal, biopsy margin refinement, small wound-edge trimming, and direct surface cutting. The curved 5-1/2" (14 cm) variant is selected when the target tissue is elevated with forceps or follows a curved contour. It supports work around mucosal flaps, nasal soft tissue, gingival margins, scar edges, and undermined skin. Jones Dissecting Scissors should be selected according to tissue plane, access angle, and whether the surgeon is cutting across a flat surface or beneath a raised edge. Keeping both variants in a minor surgery tray gives the clinical team direct-line and side-entry cutting options without changing handle control.</p>

<p><strong>What do CE, ISO 13485, and FDA details mean for procurement?</strong><br>CE documentation supports international conformity records for reusable surgical instrument purchasing. ISO 13485 indicates manufacturing under a medical device quality management system covering production control, inspection, and traceability. FDA procurement context supports U.S. purchasing files for Class I reusable surgical scissors. Jones Dissecting Scissors can be entered into hospital, clinic, distributor, dental, dermatology, and veterinary catalogs with documented material, finish, model number, warranty, MOQ, OEM availability, and after-sale service. These records help purchasing officers, receiving teams, and sterile processing departments align the item with internal approval requirements. The certification profile supports tender files, replacement stock, and standardized minor surgery tray programs.</p>

<p><strong>How does the screw-joint pivot control cutting during dissection?</strong><br>The screw-joint pivot is the main control feature because it transfers ring-handle pressure into blade closure. The operator places the thumb and ring finger in the handles while using the index finger along the shank to guide the pointed tips. As the handles close, the narrow cutting edges meet at the selected skin margin, mucosal edge, suture, or thin fibrous strand. The pivot keeps the blades aligned so the tips close evenly without a ratchet, spring, or locking catch. Jones Dissecting Scissors rely on fingertip pressure, forceps stabilization, and direct visualization rather than mechanical locking. Cleaning around the pivot is important because dried residue can alter resistance and reduce smooth closure during repeated use.</p>

<p><strong>Are these scissors suitable for reusable sterile processing and distributor stock?</strong><br>Yes, Jones Dissecting Scissors are reusable German stainless steel instruments suitable for hospital, clinic, distributor, dental, veterinary, and operating room supply workflows. After use, the blades and screw joint should be opened so blood, tissue residue, suture fragments, and lint can be removed before sterilization. Processing can include enzymatic cleaning, ultrasonic decontamination, washer-disinfector exposure, drying, pivot inspection, packaging, and steam autoclaving. The 1-piece MOQ supports replacement ordering for small clinics, procedure rooms, and specialty trays. OEM availability supports distributor branding, institutional packing, and bulk purchasing programs. The 1-year warranty and return and replacement service support procurement teams managing recurring scissor inventory.</p>

At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.

Eligibility for Returns

To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.

Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.

How to Initiate a Return

To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.

Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States

Return Shipping Costs

No Restocking Fee: We do not charge restocking fees on approved returns.

Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.

Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.

Return Conditions

Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.

Refund Process

Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.

Please note that your bank or credit card provider may require additional time to post the refund to your account.

Damaged, Defective, or Incorrect Items

Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.

Exceptions and Non-Returnable Items

Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.

Exchanges

For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.

Worldwide Shipping

Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.

European Union Customers

For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.

Contact Us

For return, refund, or exchange inquiries, please contact us:

Phone: +1 315 526 9968
Email: info@peaksurgicals.com

Related products

Recently viewed products