Instruments Set For Perfect Tibial Nails, SKU PS-OP-3604 and set code PS-075A, is a reusable orthopedic tibial intramedullary nailing system manufactured in stainless steel for controlled nail insertion, canal preparation, proximal and distal interlocking, compression and extraction. The configuration includes the Radiographic Ruler, 14x12mm Protection Sleeve, Ø12mm Cannulated Cutter, 12mm Cannulated Awl, Ø12mm Cannulated Drill Bit, 3.2 x 300mm Guide Wires, Perfect Tibial Nail Insertion Handle, Connecting Screw, Compression Screw, 6.5mm T-Handle, Multiaxial T-Handle, 141mm Connectors, Connector Part, Hammer Guide Rod, Distal Jig Guide, T-Type Distal Alignment Device, Positioning Block, Distal Aiming Arm, Proximal Aiming Arms, calibrated 3.2mm and 4mm drills, 5.2mm distal-alignment drills, sleeves, Depth Gauge, 3.5mm hexagonal drivers, Soft Tissue Separator, 2.5 x 1000mm Ball-Tip Reaming Rods, T-Type Fracture Alignment Device, L Keys, Skin Protector, locking bolts, Pin Holder, screw holder, quick-coupling T-handle, wrenches, Sliding Hammer, Nail Extractor, Reamer Shafts and Ø7.5–12mm Reamer Heads. The set is intended for orthopedic trauma surgeons performing tibial intramedullary nail fixation in hospital operating rooms and trauma centers.
The PS-075A instrumentation follows the mechanical sequence of tibial nail implantation from radiographic planning through canal access and implant attachment. The Radiographic Ruler assists preoperative or intraoperative assessment of nail dimensions, while the Skin Protector and Soft Tissue Separator establish controlled access around the entry portal. The 12mm Cannulated Awl, Cannulated Cutter and Cannulated Drill Bit work over the 3.2mm guide wire to prepare the proximal tibial entry path. The cannulated Connecting Screw secures the nail to the Insertion Handle, while the Compression Screw permits controlled compression when supported by the compatible nail construct. The 6.5mm T-Handle and Multiaxial T-Handle provide rotational access to the connecting assembly, while the 141mm Connectors and Connecting Part establish the required mechanical relationship between the insertion handle and targeting components. The Hammer Guide Rod transfers impact from the Sliding Hammer during controlled nail advancement. The Ball-Tip Reaming Rod maintains the reaming pathway through the medullary canal, and the Reamer Shafts accept interchangeable heads from Ø7.5mm through Ø12mm. This progression allows staged canal preparation while maintaining a guide-controlled trajectory before nail insertion.
After nail advancement, the proximal and distal targeting assemblies provide controlled guidance for interlocking screw preparation. The Proximal Aiming Arm and Proximal Aiming Arm-Angular establish the appropriate proximal targeting geometry for the compatible Perfect Tibial Nail configuration. The Distal Jig Guide, T-Type Distal Alignment Device, Positioning Block and Distal Aiming Arm create a mechanical targeting assembly for distal locking. The 3.2 x 250mm calibrated drill bits provide controlled drilling for compatible locking fixation, while the 3.2mm and 4mm drill stoppers limit drilling depth where required. The Ø5.2mm T-Type drill and 5.2 x 250mm drill prepare the distal alignment pathway. Protection Sleeves and Drill Sleeves maintain the drilling corridor and protect surrounding soft tissue during screw-hole preparation. The 3.2mm Drill Sleeve and Trocar Pin assembly provides a controlled access combination for distal targeting. The Depth Gauge determines locking screw length after drilling, while the 3.5mm Hexagonal Screw Driver Shaft and Hexagonal Screw Driver complete compatible screw insertion. The 6mm proximal and 8mm distal Flower-Type Locking Bolts secure the respective aiming jigs during targeting. The Pin Holder and Hexagonal Screw Holder assist controlled management of pins and screws during the fixation sequence.
The reaming system provides ten interchangeable heads from Ø7.5mm to Ø12mm in 0.5mm increments: PS-075A-7.5, PS-075A-8.0, PS-075A-8.5, PS-075A-9.0, PS-075A-9.5, PS-075A-10.0, PS-075A-10.5, PS-075A-11.0, PS-075A-11.5 and PS-075A-12.0. The smaller heads support controlled preparation of narrower tibial canals, while progressively larger heads permit staged enlargement according to the selected nail diameter and operative technique. Two PS-075A.50 Reamer Shafts carry the interchangeable heads, while two 2.5 x 3.9 x 1000mm Ball-Tip Reaming Rods maintain the reaming trajectory. The Fracture Alignment Device in T-Type configuration assists manipulation and alignment across the fracture during nail insertion. The T-Type Distal Alignment Device, Positioning Block and Distal Aiming Arm maintain the distal targeting relationship, while the Proximal Aiming Arm-Angular accommodates the proximal locking geometry of the compatible nail. The 3mm and 5mm L Keys provide adjustment of compatible assemblies, with the 11mm Combination Wrench and Pin Wrench supporting tightening and fixation of the instrumentation. The T-Handle Quick Coupling provides an additional manual interface for compatible components, while the Medullary Tube supports controlled handling of the reaming assembly and guide system.
The Instruments Set For Perfect Tibial Nails is designed as reusable orthopedic instrumentation for repeated handling, cleaning, inspection and sterilization in professional trauma environments. Stainless steel provides the mechanical substrate required for cannulated cutters, awls, drills, guide sleeves, aiming arms, reamer shafts, screwdrivers, wrenches and extraction components subjected to controlled mechanical loading during tibial nail fixation. Reprocessing should follow the healthcare facility's validated workflow, including point-of-use cleaning, decontamination, inspection, drying, packaging and sterilization according to applicable manufacturer instructions. Steam autoclave sterilization is appropriate for compatible reusable stainless steel components when performed using a validated cycle. The Empty Container organizes the PS-075A instrumentation for storage, transport and sterile-processing preparation. Peak Surgicals supports medical procurement with CE marking, ISO 13485 quality-management certification and FDA-compliant procurement support for applicable healthcare markets. The set is listed at $1,265.75 USD and carries the standard Peak Surgicals procurement configuration of one complete set, with reusable construction intended for orthopedic hospitals, trauma centers, clinics and medical distributors. The system includes dedicated instruments for nail insertion, proximal and distal targeting, reaming and extraction rather than relying on general-purpose orthopedic instrumentation.
| SKU | PS-OP-3604 |
|---|---|
| Product Name | Instruments Set For Perfect Tibial Nails – PS-075A |
| Price | $1,265.75 USD |
| Size/Gauge Variants | Reamer Heads Ø7.5mm, Ø8.0mm, Ø8.5mm, Ø9.0mm, Ø9.5mm, Ø10mm, Ø10.5mm, Ø11mm, Ø11.5mm and Ø12mm; 3.2mm and 4mm calibrated drills; Ø5.2mm distal-alignment drills |
| Instrument Category | Orthopedic Tibial Intramedullary Nail Instrument Set |
| Procedure | Tibial intramedullary nail insertion, canal reaming, proximal and distal interlocking, fracture alignment and nail extraction |
| Material | Stainless Steel |
| Finish | Satin / Dull / Mirror |
| Sterilization | Reusable; steam autoclave sterilization following validated hospital reprocessing procedures |
| Instrument Classification | Class I |
| Reusable | Yes |
| Certifications | CE Mark, ISO 13485, FDA-compliant procurement support |
| Warranty | 1 Year |
| MOQ | 1 Set |
| OEM / Custom Orders | Available |
| After-Sale Service | Return and Replacement |
Details of Instruments Set For Perfect Tibial Nails is Given Below.
|
PS-075A Instruments Set For Perfect Tibial Nails |
|
|
Set Consisting of : |
Units |
|
PS-075A.01 - Radiographic Ruler for Perfect Tibial Nail |
1 |
|
PS-075A.02 - Protection Sleeve 14x12mm |
1 |
|
PS-075A.03 - Cannulated Cutter for Perfect Tibial Nail Ø 12mm |
1 |
|
PS-075A.04 - Awl 12mm - cannulated |
1 |
|
PS-075A.05 - Drill Bit Ø 12mm - cannulated |
1 |
|
PS-075A.06 - Guide Wire 3.2 mm x 300mm |
3 |
|
PS-075A.07 - Insertion Handle for Perfect Tibial Nail |
1 |
|
PS-075A.08 - Connecting Screw, cannulated short for Perfect Tibial Nail |
1 |
|
PS-075A.09 - Compression Screw for Perfect Tibial Nail |
1 |
|
PS-075A.10 - T.Handle for Connecting Screw 6.5mm |
1 |
|
PS-075A.11 - Multiaxial T.Handle for Connecting Screw 6.5mm |
1 |
|
PS-075A.12 - Connector for Insertion Handle, Length 141mm |
2 |
|
PS-075A.13 - Connecting Part for Connector |
1 |
|
PS-075A.14 - Hammer Guide Rod |
1 |
|
PS-075A.15 - Distal Jig Guide |
1 |
|
PS-075A.16 - Distal Allignment Device (T-Type) |
1 |
|
PS-075A.17 - Positioning Block for Distal Allignment Device |
1 |
|
PS-075A.18 - Distal Aiming Arm |
1 |
|
PS-075A.19 - Connecting Part of Distal Aiming Arm |
1 |
|
PS-075A.20 - Hexagonal Screw Driver Shaft 3.5 Tip, Long |
1 |
|
PS-075A.21 - Proximal Aiming Arm |
1 |
|
PS-075A.22 - Proximal Aiming Arm-Angular |
1 |
|
PS-075A.23 - Drill Bit 3.2 x 250 Calibrated |
2 |
|
PS-075A.39 - Drill Bit Stopper 3.2mm |
1 |
|
PS-075A.24 - Drill Bit 4 x 300mm |
3 |
|
PS-075A.38 - Drill Bit Stopper 4mm |
1 |
|
PS-075A.25 - T-Type Drill Bit Ø5.2mm for Distal Allignment Device |
1 |
|
PS-075A.26 - Drill Bit 5.2 x 250mm for Distal Allignment Device |
1 |
|
PS-075A.27 - Protection Sleeve 8.1 ID x 10 OD |
2 |
|
PS-075A.28 - Drill Sleeve 8.0 x 4mm |
2 |
|
PS-075A.29 - Drill Sleeve 8.0 x 5.2mm |
1 |
|
PS-075A.30 - Protection Sleeve with 3.2 Drill Sleeve & Trocar Pin (Set of 3) |
1 Set |
|
PS-075A.31 - Depth Gauge |
1 |
|
PS-075A.32 - Hexagonal Screw Driver 3.5mm Tip |
1 |
|
PS-075A.33 - Soft Tissue Separator |
1 |
|
PS-075A.34 - Reaming Rod (with Ball Tip) 2.5 x 3.9 x 1000 mm |
2 |
|
PS-075A.35 - Fracture Allignment Device (T-Type) |
1 |
|
PS-075A.36 - L Key 5mm |
1 |
|
PS-075A.37 - L Key 3mm |
1 |
|
PS-075A.40 - Skin Protecter (Small) |
1 |
|
PS-075A.41 - Locking Bolt (Flower Type) for Proximal Jig - 6mm |
2 |
|
PS-075A.42 - Locking Bolt (Flower Type) for Distal Jig - 8mm |
2 |
|
PS-075A.43 - Pin Holder |
1 |
|
PS-075A.44 - Hexagonal Screw Holder 3.5mm |
1 |
|
PS-075A.45 - T-handle -Quick Coupling |
1 |
|
PS-075A.46 - Pin Wrench |
1 |
|
PS-075A.47 - Combination Wrench 11mm |
1 |
|
PS-075A.48 - Sliding Hammer |
1 |
|
PS-075A.49 - Nail Extractor |
1 |
|
PS-075A.50 - Reamer Shaft |
2 |
|
PS-075A-7.5 - Reamer Head Ø 7.5 mm |
1 |
|
PS-075A-8.0 - Reamer Head Ø 8.0 mm |
1 |
|
PS-075A-8.5 - Reamer Head Ø 8.5 mm |
1 |
|
PS-075A-9.0 - Reamer Head Ø 9.0 mm |
1 |
|
PS-075A-9.5 - Reamer Head Ø 9.5 mm |
1 |
|
PS-075A-10.0 - Reamer Head Ø 10 mm |
1 |
|
PS-075A-10.5 - Reamer Head Ø 10.5 mm |
1 |
|
PS-075A-11.0 - Reamer Head Ø 11 mm |
1 |
|
PS-075A-11.5 - Reamer Head Ø 11.5 mm |
1 |
|
PS-075A-12.0 - Reamer Head Ø 12 mm |
1 |
|
PS-075A.51 - Medullary Tube |
1 |
|
PS-075A.000 - Empty Container |
1 |
|
Distal Jig Assembly For Perfect Tibial Nails |
|
|
Proximal Locking |
|
|
Proximal Locking |
|
|
Distal Locking |
|
How does the Perfect Tibial Nail Instrument Set differ from a general tibial intramedullary nail set?
The Perfect Tibial Nail Instrument Set is specifically configured around the Perfect Tibial Nail system. It includes a dedicated insertion handle, connecting screw, compression screw and compatible proximal and distal targeting assemblies. The set also provides a dedicated T-Type Distal Alignment Device with positioning block and aiming arm. Its reaming system spans Ø7.5mm to Ø12mm through ten interchangeable heads. General tibial nailing sets may use different connector, targeting and reamer configurations. The PS-075A arrangement therefore keeps nail assembly, targeting and extraction components matched to the Perfect Tibial Nail workflow.
How are the Ø7.5–12mm reamer heads selected during tibial canal preparation?
The PS-075A set provides ten reamer heads from Ø7.5mm through Ø12mm in 0.5mm increments. Smaller diameters are used at the beginning of progressive canal preparation, particularly where the tibial medullary canal requires controlled enlargement. Larger heads are selected sequentially according to the intended nail diameter and operative technique. The Ball-Tip Reaming Rod maintains the guide path through the canal while the interchangeable Reamer Shaft carries the selected head. The 3.2 x 300mm Guide Wire establishes the initial cannulated trajectory. Final reaming should follow the compatible Perfect Tibial Nail surgical technique.
What do CE, ISO 13485 and FDA procurement support mean for this instrument set?
The Instruments Set For Perfect Tibial Nails is supplied within Peak Surgicals' medical-device quality and procurement framework. CE marking addresses applicable European conformity requirements. ISO 13485 relates to the manufacturer's medical-device quality-management system. FDA-compliant procurement support is relevant to applicable US healthcare purchasing workflows. Hospitals and distributors can use the associated regulatory documentation during supplier qualification and purchasing review. Product and regulatory records should be retained according to the purchasing institution's requirements.
How do the proximal and distal aiming devices function during tibial nail locking?
The Proximal Aiming Arm establishes the targeting relationship for compatible proximal locking holes. The Angular Proximal Aiming Arm provides an alternative geometry for compatible proximal locking trajectories. At the distal end, the Distal Jig Guide, T-Type Distal Alignment Device, Positioning Block and Distal Aiming Arm form the targeting assembly. The 6mm and 8mm Flower-Type Locking Bolts secure the proximal and distal jig components during setup. The calibrated drill bits and corresponding sleeves then guide preparation for compatible locking screws. The Depth Gauge and 3.5mm hexagonal drivers complete the measurement and insertion sequence.
Is the Perfect Tibial Nail Instrument Set suitable for hospital sterilization and procurement?
The set is designed as reusable orthopedic instrumentation for professional trauma surgery. Components should undergo cleaning, inspection, drying, packaging and validated sterilization according to the healthcare facility's reprocessing protocol and applicable manufacturer instructions. Steam autoclaving is used for compatible reusable stainless steel components under a validated cycle. The Empty Container provides organized storage for the complete PS-075A configuration. The set includes both implantation and extraction instruments, allowing the operating department to maintain the required Perfect Tibial Nail workflow in one organized configuration. It is suitable for hospital, trauma-center, orthopedic-clinic and distributor procurement.