The Fiber Optic Macintosh Laryngoscope Set 4 Blades is designed for airway visualization and endotracheal intubation in anesthesia, emergency medicine, critical care, and surgical environments. The system combines fiber optic illumination with reusable stainless steel laryngoscope components and an ergonomic battery handle for controlled airway examination and intubation procedures.

The current Peak Surgicals listing identifies SKU PS-L-001000-1-3-1. The product title states “4 Blades,” while the current product description states that the set contains three fiber optic blades and one battery handle. Buyers should therefore confirm the exact blade count and included blade sizes before ordering.

Fiber Optic Airway Illumination

The laryngoscope uses fiber optic illumination to direct light toward the airway during laryngoscopy. Adequate illumination allows the clinician to visualize anatomical structures while positioning the laryngoscope for airway assessment or placement of an endotracheal tube.

The current product information describes a bright, focused light output. Actual visualization also depends on blade selection, patient anatomy, handle condition, light-source performance, and clinician technique.

Macintosh Laryngoscope Configuration

This set uses the Macintosh laryngoscope pattern, a curved-blade configuration commonly selected for direct laryngoscopy and airway management. Different blade sizes allow clinicians to choose a configuration appropriate to the patient's anatomy and procedural requirements.

The live description references blade sizes suitable for both pediatric and adult airway management but does not provide the exact numerical blade-size numbers in the accessible product text. These should be confirmed before purchase when a particular Macintosh blade size is required.

Stainless Steel Blades

The fiber optic blades are described as manufactured from stainless steel, with the current page also referencing surgical-grade stainless steel construction. This provides the rigid working structure required for reusable laryngoscope blades used in professional clinical environments.

The exact stainless-steel alloy grade is not specified on the current product page. Hospitals and procurement departments requiring a specific material designation should confirm the material specification before ordering.

Ergonomic Battery Handle

The set includes an ergonomic battery handle designed to provide a controlled grip while supplying power to the fiber optic illumination system. The current description also identifies the handle as lightweight and compatible with standard fiber optic laryngoscope blades.

Exact battery type, battery quantity, handle diameter, and electrical specifications are not stated in the accessible product description and should not be assumed.

Endotracheal Intubation and Airway Management

The primary clinical context for this Fiber Optic Macintosh Laryngoscope Set is airway visualization and endotracheal intubation. The current page references use by anesthesiologists, emergency medical personnel, and intensive-care professionals in hospitals, operating rooms, emergency settings, and critical-care environments.

Laryngoscopy and intubation should only be performed by appropriately trained healthcare professionals following established airway-management protocols.

Pediatric and Adult Use Context

The current product description states that different blade sizes are intended to support both pediatric and adult airway management. Selecting the appropriate blade size is important because airway anatomy and required working dimensions differ between patients.

The exact included blade numbers are not specified in the accessible description. Buyers purchasing the set for a defined patient population should confirm the supplied blade sizes before ordering.

Autoclavable Blades

The live product information identifies the blades as autoclavable and intended for repeated use. Reprocessing should follow the blade manufacturer's validated instructions together with the healthcare facility's cleaning, disinfection, and sterilization protocols.

The current page does not provide exact autoclave temperature, pressure, exposure time, or validated cycle parameters. Those settings should therefore not be inferred from this product description.

Product Specifications

Product Name Fiber Optic Macintosh Laryngoscope Set 4 Blades
SKU PS-L-001000-1-3-1
Instrument Type Fiber Optic Laryngoscope Set
Blade Pattern Macintosh
Illumination Fiber Optic
Blade Material Stainless Steel
Handle Ergonomic Battery Handle
Patient Context Pediatric and Adult Use Referenced
Primary Application Airway Visualization and Endotracheal Intubation
Blade Reprocessing Autoclavable
Current Set Description 3 Fiber Optic Blades + 1 Battery Handle
Listing Note Page Title States “4 Blades”; Exact Included Configuration Should Be Confirmed

For Airway and Anesthesia Procurement

The Fiber Optic Macintosh Laryngoscope Set is suitable for hospitals, operating rooms, anesthesia departments, emergency departments, intensive-care units, ambulance services, surgical centers, medical distributors, and procurement teams sourcing reusable airway-management equipment.

SKU PS-L-001000-1-3-1, the Macintosh blade pattern, fiber optic illumination, stainless steel construction, and battery handle provide clear product identifiers for procurement. Because the current product title and description differ regarding the number of blades included, buyers should confirm the exact blade count and individual blade sizes before placing an order.

Frequently Asked Questions

What is the Fiber Optic Macintosh Laryngoscope Set used for?
It is designed for airway visualization and endotracheal intubation in anesthesia, emergency, critical-care, and surgical settings.

Does the set use Macintosh blades?
Yes. The current product title identifies it as a Macintosh laryngoscope set.

How many blades are included?
The page title states four blades, while the current product description states three fiber optic blades plus one battery handle. The exact supplied configuration should be confirmed before ordering.

Are the blades suitable for pediatric and adult patients?
The current product description references different blade sizes for both pediatric and adult airway management.

Are the blades autoclavable?
Yes. The current product information identifies the blades as autoclavable.

What is the product SKU?
The listed SKU is PS-L-001000-1-3-1.