The Daniel Endoscopic Forehead Transoraler Dissector 23.5cm is a specialized plastic surgery instrument designed for controlled tissue dissection during endoscopic forehead procedures. Its long working configuration and curved distal tip provide a dedicated instrument profile for surgical approaches requiring access through a limited operative field.
The current Peak Surgicals model is identified as SKU PS-ES-0018. It features a 7 mm wide curved tip, an overall length of 23.5 cm (9¼ inches), and stainless-steel construction.
The instrument has a confirmed overall length of 23.5 cm (9¼ inches). This extended length provides working reach during endoscopic forehead and related plastic surgery procedures while allowing the surgeon to maintain control from the handle.
The 23.5 cm length is an important purchasing specification when distinguishing this Transoraler Dissector from other Daniel Endoscopic Forehead instruments such as elevators, nerve dissectors, retractors, and scissors.
The current Peak Surgicals description confirms a 7 mm wide distal working end. This provides a defined working surface for tissue-plane dissection and manipulation during the intended surgical application.
The page does not state the exact tip thickness, edge profile, radius, or additional distal dimensions. These measurements should therefore be confirmed before ordering if they are important to a specific surgical technique.
The Daniel Transoraler Dissector features a curved tip. This distal configuration distinguishes it from straight Daniel patterns and provides an angled working profile for endoscopic dissection.
The exact degree of curvature is not stated on the current Peak Surgicals page and should not be assumed from another manufacturer's Daniel instrument.
Peak Surgicals specifically identifies this instrument as a Daniel Endoscopic Forehead Transoraler Dissector. The Transoraler designation is part of the confirmed product pattern and should be retained in the product title and purchasing documentation.
This instrument should not be confused with Peak Surgicals' separate Daniel Endoscopic Forehead scissors, nerve dissectors, scalp elevators, suction elevators, or retractors, which have different working ends and product codes.
Peak Surgicals lists this instrument within its Endoscopic Face and Forehead Lift product range. Comparable Daniel Transoraler Dissector patterns are also categorized as plastic surgery instruments used in endoscopic procedures.
The exact tissue plane, access route, and method of dissection should be determined by the operating surgeon according to the procedure, anatomy, and selected endoscopic technique.
The instrument's long 23.5 cm shaft, curved 7 mm working end, and stainless-steel construction provide a clearly defined configuration for plastic surgery instrument sets requiring a Daniel pattern endoscopic dissector.
Hospitals and surgical centers assembling an endoscopic forehead set should verify the exact Daniel pattern required because several instruments in this family share similar overall lengths while having different tip shapes and functions.
The current Peak Surgicals product description confirms stainless-steel construction. The rigid metallic design provides the structural form required for a long surgical dissector used in professional operating-room environments.
The exact stainless-steel alloy grade is not stated on the current page. Buyers requiring a particular alloy designation, finish, or material certificate should confirm those specifications before ordering.
Before clinical use, the curved 7 mm working end, shaft, and handle should be inspected for visible deformation, surface damage, corrosion, or other conditions that could interfere with normal instrument handling.
The current Peak Surgicals page does not provide detailed sterilization-cycle parameters or reprocessing instructions. The instrument should therefore be cleaned and processed according to applicable manufacturer guidance and the healthcare facility's validated procedures.
| Product Name | Daniel Endoscopic Forehead Transoraler Dissector |
| SKU | PS-ES-0018 |
| Instrument Type | Endoscopic Surgical Dissector |
| Pattern | Daniel Transoraler |
| Overall Length | 23.5 cm / 9¼ Inches |
| Tip Width | 7 mm |
| Tip Configuration | Curved |
| Material | Stainless Steel |
| Product Range | Endoscopic Face and Forehead Lift Instruments |
| Specialty Context | Plastic Surgery / Endoscopic Forehead Procedures |
| Exact Tip Thickness | Not Specified on Current Product Page |
| Exact Curve Angle | Not Specified on Current Product Page |
The Daniel Endoscopic Forehead Transoraler Dissector is relevant for plastic surgery departments, endoscopic facial surgery centers, hospitals, surgical instrument distributors, and procurement teams sourcing specialized Daniel-pattern forehead instruments.
For accurate purchasing and inventory identification, buyers can reference SKU PS-ES-0018 together with the 23.5 cm overall length, 7 mm curved tip, Transoraler pattern, and stainless-steel construction. Buyers requiring exact tip thickness, shaft diameter, handle dimensions, curvature angle, or stainless-steel alloy grade should confirm those details before ordering because they are not stated on the current Peak Surgicals page.
It is a specialized endoscopic plastic surgery dissector with a curved 7 mm working tip and 23.5 cm overall length.
The current Peak Surgicals model measures 23.5 cm (9¼ inches).
The confirmed tip width is 7 mm.
The current Peak Surgicals description specifies a curved tip.
The current product page specifies stainless steel. The exact stainless-steel alloy grade is not stated.
The current Peak Surgicals SKU is PS-ES-0018.