PEAK SURGICAL
Clamp for Premolar – Stainless Steel Rubber Dam Clamp for Premolar Teeth
Clamp for Premolar – Stainless Steel Rubber Dam Clamp for Premolar Teeth
SKU:PS-D-116
Couldn't load pickup availability
- 30 Days Money Back Guarantee.
- 100% Quality Satisfaction.
- Medical Grade Steel Reusable.
CE Certified
FDA Certified
ISO Certified

The Clamp for Premolar from Peak Surgicals is a reusable endodontic rubber dam clamp manufactured from stainless steel, specifically designed to engage the cervical contour of premolar teeth and retain the rubber dam sheet securely during root canal treatment and restorative procedures performed on first and second premolars. Sold as a single piece, this clamp is used by general dentists, endodontists, and restorative clinicians in dental practices, dental schools, and hospital dental departments worldwide.
Premolar-Specific Jaw Geometry for Accurate Cervical Engagement
The Clamp for Premolar is sized and profiled for the cervical anatomy of premolar teeth, which have a narrower bucco-lingual crown width and a smaller cervical circumference than molars. Using a molar clamp on a premolar tooth results in a jaw spread that is too wide to engage the cervical contour securely, causing the clamp to rock rather than grip. The Clamp for Premolar provides four-point contact scaled to the premolar crown, allowing the clamp jaws to engage the buccal, lingual, and interproximal cervical margins accurately and maintain stable retention throughout the procedure without slippage. Accurate clamp selection by tooth type is the single most controllable factor in rubber dam isolation quality.
Premolar Root Canal Treatment and Restorative Isolation
Premolars are among the most commonly root canal treated teeth in general dental practice, with first and second premolars presenting single, two-canal, and three-canal anatomies that require thorough irrigation and precise obturation under rubber dam isolation. The Clamp for Premolar anchors the rubber dam at the premolar itself when treating that tooth — or at the premolar as an anterior anchor tooth during molar root canal treatment — providing a stable isolation foundation for the endodontic procedure. The same clamp profile is used for direct composite resin restorations and glass ionomer placements on premolar teeth where moisture control is essential for reliable adhesive bonding.
Narrower Bow Span Suited to Premolar Crown Dimensions
The bow of the Clamp for Premolar is proportioned to span the occlusal surface of a premolar tooth without extending excessively into the buccal or lingual sulci. An appropriately sized bow span allows the clamp forceps to engage the bow holes for placement and removal without the bow contacting adjacent teeth or soft tissue during the clinical manoeuvre. The narrower profile of this clamp compared to molar clamps also reduces the bulk at the anchor tooth site, improving access for the clinician during posterior premolar procedures where visibility and instrument access are more restricted than in the anterior arch.
Stainless Steel Construction for Repeated Clinical Use
Each Clamp for Premolar is manufactured from stainless steel, providing the structural rigidity and spring tension required to maintain consistent four-point jaw contact against premolar cervical anatomy throughout the clinical procedure. The clamp maintains its jaw geometry and bow profile across repeated clinical use and sterilization cycles without fatigue deformation, ensuring reliable cervical engagement over the instrument's service life. Stainless steel construction ensures the clamp is rust-free and compatible with standard decontamination and sterilization protocols used in licensed dental facilities.
CE Mark, ISO 13485, and FDA Certification for Dental Instrument Procurement
The Clamp for Premolar is manufactured under CE Mark, ISO 13485, and FDA compliant quality standards. ISO 13485 certification confirms Peak Surgicals operates a documented quality management system covering design control, material traceability, and production consistency for dental instruments. CE Mark confirms conformity with European medical device regulations, and FDA compliance supports procurement for US-based dental practices, dental schools, and hospital dental departments requiring verified regulatory documentation.
Product Specifications
| SKU | — (verify in Shopify admin) |
|---|---|
| Product Name | Clamp for Premolar |
| Price | $3.30 USD |
| Tooth Type | Premolars (first and second, upper and lower) |
| Clamp Type | Premolar Rubber Dam Clamp |
| Instrument Category | Endodontic |
| Material | Stainless Steel |
| Certifications | CE Mark, ISO 13485, FDA |
| Reusability | Reusable |
| Quantity | 1 Piece |
| Rust Resistance | Yes |
| Warranty | 1 Year |
| MOQ | 1 Piece |
| OEM / Custom Orders | Available |
| Packing | Carton Box |
| Primary Use | Anchor rubber dam sheet at premolar teeth during endodontic and restorative procedures requiring field isolation |
| After-Sale Service | Return and Replacement |
Frequently Asked Questions
Why is a premolar-specific rubber dam clamp needed rather than using a molar clamp?
Premolar teeth have a significantly narrower bucco-lingual crown width and smaller cervical circumference than molars. A molar clamp applied to a premolar will have a jaw spread too wide to engage the cervical contour at four contact points — instead of gripping the tooth, the jaws will straddle it and rock, allowing the clamp to dislodge under the forces of clinical activity and disrupting the rubber dam seal. The Clamp for Premolar from Peak Surgicals is sized for premolar crown anatomy, providing stable four-point cervical contact that holds through access preparation, irrigation, and obturation without requiring re-seating during the procedure.
Which premolars is this clamp designed for?
The Clamp for Premolar is designed for use on upper and lower first and second premolars. These teeth share a broadly similar bucco-lingual crown width range, making a single premolar clamp profile suitable for the majority of premolar anchor tooth situations encountered in general and specialist dental practice. Individual variation in premolar crown width exists — particularly between upper first premolars, which are typically the widest in the premolar group, and lower second premolars. Inspect the clamp jaw fit against the crown anatomy at placement and confirm stable four-point contact before proceeding with the rubber dam sheet.
When is the premolar used as the anchor tooth rather than treating it directly?
In molar root canal treatment, the premolar adjacent to the molar being treated is sometimes used as the anterior anchor tooth for the rubber dam clamp when the molar crown anatomy is insufficient to retain a clamp — for example, following extensive coronal breakdown, crown placement, or when the molar is being accessed via a crown preparation. Anchoring at the premolar and punching a hole over the molar allows the rubber dam to isolate the molar field without requiring the molar itself to retain the clamp. The Clamp for Premolar provides the correct jaw profile for stable premolar cervical engagement in this configuration.
Is this clamp compatible with autoclave sterilization?
The Clamp for Premolar is a reusable stainless steel instrument, fully compatible with standard autoclave and steam sterilization protocols used in licensed dental facilities. Each clamp withstands repeated thermal sterilization cycles without deformation of the bow or jaw geometry. Facilities should follow their own validated sterilization cycle parameters and reprocessing protocols for Class I reusable dental instruments, and should inspect jaw tips before each clinical use for wear or deformation that could reduce cervical contact stability.
What certifications does this clamp carry?
The Clamp for Premolar is manufactured under CE Mark, ISO 13485, and FDA compliant quality standards. ISO 13485 certification confirms Peak Surgicals operates a documented quality management system covering design control, material traceability, and manufacturing consistency for dental instruments. CE Mark confirms conformity with European medical device regulations, and FDA compliance supports procurement for US dental practices, dental schools, and hospital dental departments requiring verified regulatory documentation.
Can this clamp be ordered with molar clamps as part of an assortment?
OEM manufacturing and custom orders are available from Peak Surgicals for dental distributors, endodontic procurement departments, and institutional buyers requiring premolar and molar clamp assortments, specific profile combinations, custom engraving, or packaging formats. The standard minimum order quantity is 1 piece for individual practice restocking. Peak Surgicals also supplies molar rubber dam clamps in separate listings — contact Peak Surgicals directly for guidance on building a complete rubber dam clamp tray to cover the full range of anchor tooth situations encountered in endodontic and restorative practice.