Skip to product information

Cancellous Screws 3.0mm for Veterinary TPLO Bone Fixation

Cancellous Screws 3.0mm are veterinary orthopedic bone screws designed for TPLO fixation, cancellous bone purchase, plate stabilization, and controlled bone fixation where a 3.0mm cancellous screw is selected for the...
In stock
Price:
$2.20
  • Secure Checkout

    Secured Checkout Guaranteed.

  • 30 Day's Money Back

    30 Day's Money Back Guaranteed.

  • Free Shipping On 99 $

    Free Shipping on Orders Above 99 $.

Cancellous Screws 3.0mm for Veterinary TPLO Bone Fixation
Regular price $2.20
Regular price Sale price $2.20 (-0%)
Size: Cancellous Screws 3.0mm - Fully Threaded 10mm Length.
Cancellous Screws 3.0mm
Cancellous Screws 3.0mm for Veterinary TPLO Bone Fixation
$2.20

Cancellous Screws 3.0mm are veterinary orthopedic bone screws designed for TPLO fixation, cancellous bone purchase, plate stabilization, and controlled bone fixation where a 3.0mm cancellous screw is selected for the operative plan. The cancellous thread profile supports engagement in metaphyseal and cancellous bone regions during veterinary orthopedic procedures. The screw is used during tibial plateau leveling osteotomy, small bone fixation, periarticular stabilization, orthopedic plate application, and canine cranial cruciate ligament repair workflows where bone fixation must match the selected implant system. Veterinary orthopedic surgeons, referral hospitals, TPLO teams, small animal surgical units, distributors, and procurement departments use this screw pattern in orthopedic implant trays where diameter-specific screw selection, thread purchase, and compatible instrumentation are required. The stainless steel construction supports veterinary implant inventory planning, while the $2.20 price point supports replenishment of screw racks and TPLO fixation sets used in routine orthopedic procedures.

3.0mm Diameter, Cancellous Thread Profile, and Orthopedic Screw Control

The Cancellous Screws 3.0mm pattern is selected when the surgeon requires a smaller cancellous screw diameter for veterinary orthopedic fixation. The cancellous thread profile is designed for purchase in lower-density cancellous bone rather than dense cortical shaft bone. This makes the screw useful in metaphyseal regions, periarticular bone, TPLO plate fixation points, and smaller orthopedic constructs where a 3.0mm screw matches the planned implant system. During placement, the screw is selected after exposure, plate positioning, drilling, depth assessment, and confirmation of bone quality. The screw is advanced with compatible orthopedic instrumentation according to the surgical system being used. The thread geometry contributes to stable engagement along the prepared bone path while the head seats against the selected plate or bone surface. This configuration supports predictable fixation when screw diameter, thread form, bone density, and plate hole compatibility must align with the procedure plan.

TPLO Fixation, Canine Orthopedic Repair, and Plate Stabilization

Clinical use begins after orthopedic planning, patient positioning, surgical exposure, osteotomy or fracture preparation, and implant selection. During TPLO procedures, Cancellous Screws 3.0mm can be selected when the fixation construct requires cancellous bone purchase and diameter-specific screw placement through the planned plate hole. During canine cranial cruciate ligament repair workflows, the screw supports plate stabilization after the tibial plateau correction has been positioned according to the surgical plan. In smaller orthopedic constructs, the 3.0mm diameter provides an option when larger cancellous screws are not appropriate for available bone stock or implant geometry. The screw is used with drill guides, depth gauges, taps when required, screwdrivers, reduction forceps, retractors, TPLO plates, and screw racks. Correct selection follows bone depth, plate design, screw trajectory, patient size, bone quality, and fixation objective. The goal is stable bone purchase without mismatching the diameter or working length to the prepared track.

Size Selection, Implant Tray Workflow, and Driver Compatibility

This product is selected when the orthopedic plan specifies a 3.0mm cancellous screw for veterinary fixation. The available page data shows a size selector, but exact size labels are not visible in the indexed product data, so the screw should be selected according to the size options shown in the Shopify variant menu during ordering. In the operating room, screw length selection follows intraoperative depth measurement and plate position. The surgeon should use compatible drivers and implant-system instrumentation to avoid damage to the screw head, thread profile, or prepared bone track. During tray setup, the screw is organized with matched drill bits, taps, depth gauges, screwdrivers, plate holders, reduction instruments, and TPLO plates. The screw should be inspected before use for thread damage, head deformation, surface defects, contamination, or packaging concerns. Proper tray organization supports efficient screw selection and replacement during orthopedic fixation.

Stainless Steel Construction, Implant Handling, and Procurement Documentation

Stainless steel construction supports mechanical strength, corrosion resistance, and dimensional consistency for veterinary orthopedic implant use. Bone screws should be handled with clean implant technique to preserve thread geometry, head integrity, and surface condition before placement. The screw should be stored in the correct rack position so the team can identify the diameter and selected size during surgery. CE marking, ISO 13485 certification, and FDA compliance support procurement documentation for veterinary hospitals, orthopedic referral centers, distributors, and institutional buyers sourcing TPLO screws and cancellous fixation components. The product’s reusable-instrument listing context includes medical-grade steel language, quality satisfaction support, and purchasing visibility for veterinary orthopedic inventory. For procurement teams, Cancellous Screws 3.0mm provide a defined screw diameter for TPLO, cancellous bone fixation, plate stabilization, and implant tray replenishment at the listed $2.20 price point.

SKU Not listed in available indexed page data
Product Name Cancellous Screws 3.0mm
Price $2.20
Diameter 3.0mm
Size/Gauge Variants Product size selector listed; exact size labels not shown in available indexed page data
Thread Type Cancellous thread profile
Instrument Category Veterinary orthopedic cancellous screw
Procedure TPLO fixation, canine cranial cruciate ligament repair workflow, cancellous bone fixation, orthopedic plate stabilization, periarticular fixation
Material Medical-grade stainless steel
Driver Compatibility Compatible orthopedic screwdriver required according to implant system
Certifications CE marked, ISO 13485 certified, FDA compliant
MOQ 1 piece

What are Cancellous Screws 3.0mm used for? Cancellous Screws 3.0mm are used in veterinary orthopedic fixation where a 3.0mm cancellous screw is required. They are commonly associated with TPLO fixation, cancellous bone purchase, plate stabilization, periarticular fixation, and canine cranial cruciate ligament repair workflows when this diameter matches the selected implant system.

Why is a cancellous thread profile used? A cancellous thread profile is selected for engagement in cancellous or metaphyseal bone, where the bone structure differs from dense cortical shaft bone. The thread geometry supports purchase in lower-density bone regions during orthopedic plate fixation and TPLO construct assembly.

How is screw size selected during surgery? Screw size is selected after preoperative planning and intraoperative measurement using compatible orthopedic instruments. The surgeon matches the screw diameter and length to bone depth, plate hole position, patient size, bone quality, and fixation objective. The Shopify page includes a size selector, so the ordering variant should match the required operative inventory.

What instruments are used with this screw? Cancellous Screws 3.0mm are used with compatible drill bits, drill guides, depth gauges, taps when required, orthopedic screwdrivers, reduction forceps, plate holders, TPLO plates, and screw racks. Driver compatibility should match the screw head and implant system to preserve insertion control.

How do CE, ISO 13485, and FDA compliance support procurement? CE marking, ISO 13485 certification, and FDA compliance support documented sourcing for veterinary orthopedic implants and fixation components. These credentials help veterinary hospitals, orthopedic referral centers, distributors, and procurement departments maintain purchasing records for TPLO screws, cancellous screws, plates, and implant systems.

At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.

Eligibility for Returns

To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.

Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.

How to Initiate a Return

To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.

Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States

Return Shipping Costs

No Restocking Fee: We do not charge restocking fees on approved returns.

Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.

Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.

Return Conditions

Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.

Refund Process

Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.

Please note that your bank or credit card provider may require additional time to post the refund to your account.

Damaged, Defective, or Incorrect Items

Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.

Exceptions and Non-Returnable Items

Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.

Exchanges

For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.

Worldwide Shipping

Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.

European Union Customers

For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.

Contact Us

For return, refund, or exchange inquiries, please contact us:

Phone: +1 315 526 9968
Email: info@peaksurgicals.com

Related products

Recently viewed products