Skip to content
Featured Collection
PEAK SURGICALS
SKU:PS-OP-4649
CE Certified
FDA Certified
ISO Certified

The Cancellous Bone Screw Ø 4.5mm Full Thread is an orthopedic implant screw available in a broad range of lengths for cancellous bone fixation applications. Its fully threaded configuration provides thread coverage along the screw body, while the available stainless steel and titanium options allow the required material and length to be selected for the planned orthopedic fixation system.
The current Peak Surgicals product is identified by main SKU PS-OP-4649. Available lengths range from 40 mm to 120 mm in 5 mm increments, with separate catalog codes listed for stainless steel and titanium versions.
The product is specifically identified as a 4.5mm cancellous bone screw with full thread. The fully threaded configuration distinguishes this model from partially threaded cancellous screws and should be considered when selecting the required screw type for an orthopedic implant construct.
The current product page does not state thread pitch, core diameter, head diameter, head profile, drive type, or exact thread geometry. Buyers requiring these specifications should confirm them before ordering.
The current Peak Surgicals listing provides 17 screw lengths, beginning at 40 mm and extending to 120 mm in 5 mm increments. This provides multiple length options within the same 4.5mm fully threaded cancellous screw range.
The listed lengths are 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, and 120 mm.
The live product table includes a stainless steel version for every listed screw length. Each stainless-steel configuration has its own catalog code beginning with the 106 series.
The exact stainless-steel alloy grade is not stated on the current product page. Hospitals, orthopedic centers, distributors, and procurement teams requiring a specific alloy specification or supporting material documentation should confirm that information before purchase.
The same length range is also listed in titanium. Peak Surgicals provides a separate titanium catalog code for every screw length from 40 mm through 120 mm.
The exact titanium alloy or grade is not specified on the current product page. Buyers requiring a particular titanium specification should confirm it before ordering.
The Cancellous Bone Screw Ø 4.5mm Full Thread is positioned within the Peak Surgicals orthopedic implant range. Its cancellous screw design and multiple length options allow the appropriate configuration to be selected as part of a compatible orthopedic fixation system.
The exact clinical indication, bone location, plate compatibility, insertion technique, and screw length should be determined by the operating orthopedic surgeon according to the planned fixation construct.
The product title specifically confirms a full-thread design. This means the screw should be distinguished from partially threaded cancellous bone screws when preparing an orthopedic implant order or instrument-and-implant set.
The current Peak Surgicals page does not state the thread pitch or exact threaded length for each screw. Those technical details should therefore not be inferred from other manufacturers' 4.5mm cancellous screws.
The live storefront includes both Material and Size selectors. Accurate ordering therefore requires confirmation of the required material together with the required screw length.
The main storefront SKU identifies the overall product family, while the catalog table provides the individual code associated with each material and length configuration.
| Product Name | Cancellous Bone Screw Ø 4.5mm Full Thread |
| Main SKU | PS-OP-4649 |
| Product Type | Fully Threaded Cancellous Bone Screw |
| Diameter Designation | 4.5 mm |
| Thread Configuration | Full Thread |
| Material Options | Stainless Steel / Titanium |
| 40 mm | Stainless Steel: 106.840 | Titanium: PS-106.840 |
| 45 mm | Stainless Steel: 106.845 | Titanium: PS-106.845 |
| 50 mm | Stainless Steel: 106.850 | Titanium: PS-106.850 |
| 55 mm | Stainless Steel: 106.855 | Titanium: PS-106.855 |
| 60 mm | Stainless Steel: 106.860 | Titanium: PS-106.860 |
| 65 mm | Stainless Steel: 106.865 | Titanium: PS-106.865 |
| 70 mm | Stainless Steel: 106.870 | Titanium: PS-106.870 |
| 75 mm | Stainless Steel: 106.875 | Titanium: PS-106.875 |
| 80 mm | Stainless Steel: 106.880 | Titanium: PS-106.880 |
| 85 mm | Stainless Steel: 106.885 | Titanium: PS-106.885 |
| 90 mm | Stainless Steel: 106.890 | Titanium: PS-106.890 |
| 95 mm | Stainless Steel: 106.895 | Titanium: PS-106.895 |
| 100 mm | Stainless Steel: 106.900 | Titanium: PS-106.900 |
| 105 mm | Stainless Steel: 106.905 | Titanium: PS-106.905 |
| 110 mm | Stainless Steel: 106.910 | Titanium: PS-106.910 |
| 115 mm | Stainless Steel: 106.915 | Titanium: PS-106.915 |
| 120 mm | Stainless Steel: 106.920 | Titanium: PS-106.920 |
| Exact Alloy Grades | Not Specified on Current Product Page |
| Head / Drive Specifications | Not Specified on Current Product Page |
The Cancellous Bone Screw Ø 4.5mm Full Thread is relevant for orthopedic departments, hospitals, implant distributors, surgical centers, and procurement teams sourcing cancellous screws in multiple lengths and material configurations.
For accurate purchasing, buyers should reference PS-OP-4649 together with the required stainless steel or titanium material and 40–120 mm length. Buyers requiring exact head diameter, drive configuration, thread pitch, core diameter, material alloy grade, sterilization status, or plate-system compatibility should confirm those specifications before ordering because they are not stated on the current Peak Surgicals page.
The current product title identifies it as a 4.5 mm cancellous bone screw.
Yes. Peak Surgicals specifically identifies this model as Full Thread.
The product is available from 40 mm to 120 mm in 5 mm increments, providing 17 listed lengths.
The current product table lists both stainless steel and titanium versions.
The current Peak Surgicals storefront SKU is PS-OP-4649.
No. The current product page does not provide head diameter, drive type, thread pitch, or core diameter, so these specifications should be confirmed before ordering when required.