Skip to content
Featured Collection
PEAK SURGICALS
SKU:PS-L-001000
Couldn't load pickup availability

The Adult Conventional Macintosh Laryngoscope Set is designed for direct visualization of the larynx during adult airway management and endotracheal intubation. The set combines curved Macintosh laryngoscope blades with a battery handle, providing clinicians with a conventional direct-laryngoscopy system for use in anesthesia, emergency medicine, critical care, and other clinical environments where airway access is required.
The current Peak Surgicals model is identified as SKU PS-L-001000. The listed set includes four Macintosh blades in different sizes and a battery handle, allowing the clinician to select an appropriate blade according to adult airway anatomy and procedural requirements.
The Macintosh pattern uses a characteristic curved laryngoscope blade. During conventional direct laryngoscopy, the blade is advanced along the tongue and positioned with its tip in the vallecula. Correct lifting force indirectly elevates the epiglottis and helps expose the glottis and vocal cords.
This curved-blade approach distinguishes the Macintosh pattern from straight laryngoscope blades that are used to directly elevate the epiglottis. Blade selection and positioning should be performed by an appropriately trained healthcare professional according to patient anatomy and airway-management technique.
The current product information identifies the set as containing four Macintosh blades of different sizes. Multiple blade options allow the clinician to select a configuration appropriate for the patient's airway anatomy rather than relying on a single fixed blade size.
The exact numerical blade sizes are not clearly stated on the current product page. Hospitals and procurement teams requiring specific Macintosh blade numbers should therefore confirm the four included sizes before ordering.
A primary application of the Adult Conventional Macintosh Laryngoscope Set is endotracheal intubation. During direct laryngoscopy, the instrument provides access and illumination so the clinician can identify airway landmarks, visualize the glottic opening and vocal cords, and guide placement of an appropriately selected endotracheal tube.
Laryngoscopy and tracheal intubation are clinical procedures that require appropriate training. Patient positioning, airway assessment, blade selection, and intubation technique should follow the healthcare facility's established airway-management protocols.
The set includes a battery handle that provides the power required for the laryngoscope illumination system. The handle also provides the main gripping surface through which the clinician controls blade positioning and lifting during direct laryngoscopy.
The current exact product listing is titled as a conventional Macintosh laryngoscope set, but it does not reliably specify the exact bulb, lamp, or illumination configuration. For that reason, this description does not identify the model as fiber optic. Buyers requiring a particular illumination technology should confirm the configuration before purchase.
The current Peak Surgicals description identifies the Macintosh blades as being constructed from stainless steel. Stainless-steel construction provides the rigid structure required for reusable laryngoscope blades and supports professional cleaning and reprocessing when handled according to applicable procedures.
The exact stainless-steel alloy grade is not specified on the current listing. Buyers requiring a particular material designation or technical certificate should confirm the alloy before ordering.
Conventional Macintosh laryngoscopes are relevant to clinical settings where direct airway visualization and tracheal intubation may be required. These environments include operating rooms, anesthesia departments, emergency departments, critical-care units, and other airway-management settings.
The instrument should be selected according to the individual patient's airway anatomy and the clinician's chosen intubation technique. Availability of multiple curved blades provides flexibility when different adult airway dimensions are encountered.
The Adult Conventional Macintosh Laryngoscope Set is intended for repeated professional use when the reusable components are correctly maintained and reprocessed. After use, blades should be cleaned, inspected, and reprocessed according to the manufacturer's applicable instructions and the healthcare facility's validated procedures.
Before each use, inspect the blade, blade-to-handle connection, illumination function, battery handle, and contact points. The laryngoscope should not be used if illumination is unreliable, the blade does not attach securely, or visible damage could interfere with normal operation.
| Product Name | Adult Conventional Macintosh Laryngoscope Set |
| SKU | PS-L-001000 |
| Instrument Type | Conventional Direct Laryngoscope Set |
| Blade Pattern | Macintosh |
| Blade Configuration | Curved |
| Patient Group | Adult |
| Set Contents | Four Macintosh Blades and Battery Handle |
| Blade Sizes | Four Different Sizes – Exact Numbers to Be Confirmed |
| Blade Material | Stainless Steel |
| Primary Function | Direct Airway Visualization |
| Primary Clinical Application | Endotracheal Intubation |
| Referenced Clinical Areas | Anesthesia, Emergency Medicine and Critical Care |
| Power Source | Battery Handle |
| Reuse | Reusable Laryngoscope Set |
The Adult Conventional Macintosh Laryngoscope Set is suitable for hospitals, operating rooms, anesthesia departments, emergency departments, critical-care facilities, medical distributors, and procurement teams sourcing conventional direct-laryngoscopy equipment.
For purchasing and inventory identification, buyers can reference SKU PS-L-001000, the Macintosh curved-blade pattern, four-blade set configuration, and battery handle. Buyers requiring exact blade numbers, illumination type, bulb specification, battery requirements, handle dimensions, stainless-steel grade, or compatibility with other laryngoscope systems should confirm those details before ordering because they are not reliably specified on the current product page.
It is designed for direct visualization of the adult airway and is commonly used to assist with endotracheal intubation.
The curved Macintosh blade is typically positioned in the vallecula so lifting force indirectly elevates the epiglottis and helps expose the glottis and vocal cords.
The current Peak Surgicals product information states that the set includes four Macintosh blades in different sizes.
Yes. The listed set includes a battery handle for operating the laryngoscope and powering its illumination system.
The current product title specifically identifies this model as an Adult Conventional Macintosh Laryngoscope Set. Because the existing page description contains conflicting fiber-optic wording, buyers requiring fiber-optic illumination should confirm the exact model before ordering.
The current Peak Surgicals SKU is PS-L-001000.