SKU:PS-OP-5571
Couldn't load pickup availability

Rasp for Austin Moore, SKU PS-OP-5571, is an 8-inch reusable German stainless steel femoral broach designed for canal preparation before implantation of a compatible Austin Moore prosthesis. Its tapered working body carries longitudinal cutting teeth that remove cancellous bone during controlled advancement and extraction. The proximal connection receives the corresponding rasp handle or introducer, allowing the surgeon to maintain axial direction, anteversion, coronal alignment, and preparation depth. This orthopedic instrument is used during hip hemiarthroplasty for displaced intracapsular femoral-neck fractures, selected fracture nonunion, avascular necrosis, failed internal fixation, and system-compatible proximal femoral reconstruction. Following femoral-head extraction and neck osteotomy, the surgeon establishes the medullary entry point and advances the rasp along the femoral shaft axis. Repeated withdrawal permits removal of retained bone and assessment of cortical proximity, resistance, and preparation geometry. Orthopedic trauma surgeons and hip arthroplasty specialists use the instrument in hospital operating rooms, trauma units, ambulatory surgical facilities, and specialist joint-reconstruction centers. The broach profile must correspond with the definitive Austin Moore stem and the operative technique selected for the case.
The 8-inch instrument combines a tapered distal body, broader proximal preparation zone, longitudinal cutting teeth, and handle connection. Each tooth engages cancellous bone during axial advancement, enlarging and shaping the canal according to the Austin Moore stem envelope. The working geometry is not intended to create a generic cylindrical cavity; its profile corresponds with the associated prosthesis pattern. Controlled impaction advances the broach, while extraction clears loosened bone and permits visual examination of the prepared pathway. The proximal coupling transfers force from the compatible handle through the centerline of the instrument. This alignment helps the surgeon control version and avoid unintended varus or valgus progression. Tactile resistance communicated through the handle provides information regarding cancellous engagement, distal advancement, and possible cortical contact. It does not replace preoperative templating, direct visualization, or assessment of the femoral axis. The rasp should not be forcibly rotated within the canal because eccentric loading can alter preparation geometry or damage the surrounding cortex. An unstable coupling, deformed body, asymmetrical tooth wear, or abrupt increase in resistance requires inspection before further advancement.
Clinical use begins after surgical exposure of the hip, removal of the femoral head, and neck resection at the planned osteotomy level. The proximal femur is elevated and protected before an opening instrument establishes access near the longitudinal canal axis. Rasp for Austin Moore is attached securely to its compatible handle and introduced at the anteversion required for the planned prosthesis. Controlled axial blows advance the teeth through metaphyseal and proximal diaphyseal cancellous bone. The surgeon withdraws the broach periodically to clear debris and inspect direction, depth, cortical integrity, and remaining bone. In hemiarthroplasty for an intracapsular fracture, femoral preparation is based on the stem geometry rather than the measured diameter of the excised head. Head sizing determines the external Austin Moore articulation, whereas this instrument forms the internal pathway for the prosthetic stem. Once the intended preparation is achieved, trial or definitive stem assessment follows according to the implant system. The surgeon evaluates seating depth, neck resection relationship, version, offset, limb length, and hip stability before completing implantation. The rasp should not be used to correct an inaccurately located canal entry point through forceful eccentric cutting.
The current Shopify configuration supplies one 8-inch Rasp for Austin Moore under SKU PS-OP-5571. This length provides reach for proximal femoral canal preparation while preserving an external section for handle control and extraction. Instrument length alone does not determine compatibility with every Austin Moore prosthesis. The working-body contour, distal taper, proximal width, tooth arrangement, handle connection, and intended seating depth must correspond with the selected stem system. Preoperative radiographs guide assessment of canal width, proximal femoral morphology, cortical thickness, neck resection level, and planned prosthesis dimensions. Intraoperative selection then considers the established entry point, axial progression, tactile resistance, canal depth, and trial seating. A broach should not be chosen solely because its overall length matches another instrument. Standard, broad, and narrow Austin Moore stems require preparation tools whose working envelopes reproduce their individual geometry. The live product currently offers a single 8-inch purchase option, so procurement teams should map SKU PS-OP-5571 to the exact prosthesis profile used by their facility. Tray labeling should identify the supported implant family to prevent substitution with Thompson, bipolar, or other femoral broaches.
German stainless steel supplies the rigidity, corrosion resistance, and dimensional stability required for a reusable bone-cutting instrument exposed to repeated impaction. The machined teeth require inspection after every procedure because rounded edges, chipping, bending, corrosion, or retained osseous material can affect the preparation profile. Cleaning should begin promptly so blood and bone do not dry between adjacent cutting surfaces or within the handle coupling. The instrument should be detached from its removable handle where permitted by its validated design. It is then cleaned, rinsed, inspected, dried, packaged, and steam sterilized according to the healthcare facility’s approved protocol and manufacturer instructions. CE documentation concerns conformity with the applicable European medical-device framework. ISO 13485 addresses the manufacturer’s quality management system for production, documentation, and traceability. FDA-related procurement requires the establishment, listing, labeling, importer, and market-access records applicable to the destination. Hospitals should retain the SKU, instrument-to-implant mapping, inspection history, repair activity, and sterilization records. A rasp with damaged teeth, a distorted shaft, corrosion, cracking, or an insecure proximal connection must be removed from the operative tray.
| SKU | PS-OP-5571 |
|---|---|
| Product Name | Rasp for Austin Moore |
| Price | $66.00 USD |
| Size/Gauge Variants | 8 inches |
| Instrument Category | Orthopedic femoral canal preparation instrument |
| Procedure | Austin Moore hip hemiarthroplasty and system-compatible femoral reconstruction |
| Material | German stainless steel |
| Finish | Satin orthopedic finish with machined cutting teeth |
| Sterilization | Reusable instrument for validated hospital cleaning and steam sterilization |
| Instrument Classification | Reusable orthopedic femoral rasp and broach |
| Reusable | Yes |
| Certifications | CE and ISO 13485 documentation; FDA procurement documentation according to destination-market requirements |
| Warranty | 1 year |
| MOQ | 1 instrument |
| OEM / Custom Orders | Available for documented profile, labeling, packaging, and quantity requirements |
| After-Sale Service | Order, replacement, documentation, return, and maintenance support |
How does an Austin Moore rasp differ from a Thompson rasp?
Rasp for Austin Moore prepares the femoral canal for the stem geometry of a compatible Austin Moore prosthesis. A Thompson rasp follows the preparation envelope associated with a Thompson-pattern implant. Differences can involve proximal contour, stem width, taper, tooth distribution, and intended seating depth. Similar length or appearance does not make the instruments interchangeable. Using an unmatched broach can create a canal that does not correspond with the definitive implant. Selection must follow the prosthesis family, operative technique, tray documentation, and manufacturer-defined compatibility.
How should the 8-inch rasp be selected for the femoral canal?
The 8-inch length describes the overall instrument rather than the width of its cutting envelope. Rasp for Austin Moore must still match the definitive stem profile and handle system. Preoperative templating evaluates proximal femoral morphology, canal width, cortical thickness, and planned neck resection. Intraoperative assessment considers the entry point, anteversion, axial depth, tactile resistance, and trial seating. The instrument should not be substituted for a broad, narrow, or differently contoured broach solely because its length is similar. Procurement teams should map SKU PS-OP-5571 to the exact Austin Moore implant configuration maintained by the facility.
What do CE, ISO 13485, and FDA references mean for procurement?
CE documentation concerns conformity with applicable European medical-device requirements. ISO 13485 addresses the quality management system governing medical-device manufacture and traceability. Neither designation independently means that Rasp for Austin Moore has received FDA approval. United States purchasing requires the relevant establishment, listing, labeling, importer, and market-access records. Hospitals should retain those documents with the ordered SKU, instrument pattern, and supplier information. The records support vendor qualification, inventory management, maintenance, and complaint handling.
How does the handle connection control the rasp?
The proximal connection joins Rasp for Austin Moore to a compatible handle or introducer. A fully engaged coupling transfers axial impact and extraction force through the broach centerline. The surgeon uses the handle to maintain anteversion, coronal alignment, depth, and rotational orientation. Tactile resistance helps identify changing cancellous engagement and possible cortical proximity. The coupling should be checked before every insertion and after difficult extraction. A loose, worn, deformed, or contaminated connection must be removed from operative use.
How should the cutting teeth be cleaned and inspected?
Bone and biological residue should be removed before they dry between the cutting surfaces. Rasp for Austin Moore should be detached from its handle where permitted and processed under the facility’s validated cleaning procedure. Each tooth requires inspection for retained debris, rounding, chipping, bending, corrosion, and impact damage. The instrument body and proximal connection should also be examined for deformation or cracking. After cleaning and drying, the rasp can be packaged and steam sterilized according to validated institutional and manufacturer instructions. An incompletely cleaned or damaged broach should not be released for surgery.