Skip to content
Couldn't load pickup availability
Secured Checkout Guaranteed.
30 Day's Money Back Guaranteed.
Free Shipping on Orders Above 99 $.

McPherson Two Pin Bipolar Forceps Non-Stick, SKU PS-1091, are reusable non-stick bipolar electrosurgical forceps manufactured from German stainless steel with an insulated black body for precise localized coagulation in fine operating room procedures. The available tip size variants are 0.5 mm, 0.7 mm, 1.0 mm, 1.5 mm, and 2.0 mm under model PS-1091, allowing selection according to vessel diameter, tissue contact width, working depth, and coagulation footprint. The instrument pattern includes fine opposing bipolar tips, a two-pin connector interface, black insulated forceps body, spring-action tweezer control, reusable Class I construction, and non-stick distal contact surfaces for repeated hemostatic work. These forceps are used during ophthalmic tissue coagulation, ENT mucosal hemostasis, neurosurgical support, plastic surgery flap-edge refinement, dermatologic lesion bed control, oral and maxillofacial soft tissue management, gynecology fine bleeding-point control, and veterinary microsurgical workflows. Surgeons, hospitals, clinics, ambulatory surgery centers, distributors, and procurement departments use this instrument where McPherson-style handling, two-pin bipolar connection, non-stick tip control, and sterile tray compatibility are required.
The McPherson Two Pin Bipolar Forceps Non-Stick pattern works through two fine opposing tips that deliver bipolar current across the contacted tissue segment. The McPherson-style body provides delicate tweezer handling for small bleeding points, mucosal surfaces, eyelid planes, wound margins, flap edges, and narrow soft tissue corridors. Spring-action control keeps the forceps open at rest and allows the surgeon to close the tips with measured thumb and finger pressure before activation. Bipolar current passes between the two distal tips, concentrating coagulation at the grasped or contacted tissue instead of using a monopolar return pathway. The non-stick distal profile supports repeated coagulation by reducing tissue adherence at the active contact area. The black insulated body separates the handling region from the conductive distal end and supports quick identification in electrosurgical trays. The two-pin connector interface links the instrument to a compatible bipolar cable and generator setup. German stainless steel working components provide tip alignment, spring response, connector reliability, and reusable handling durability through repeated clinical cycles.
During ophthalmic and periocular procedures, McPherson Two Pin Bipolar Forceps Non-Stick support fine coagulation around conjunctival tissue, eyelid planes, lacrimal access, and small bleeding points where compact distal control is required. ENT surgeons use the fine insulated pattern during nasal mucosal work, auricular soft tissue procedures, tonsillar bed support, otologic access, and head and neck steps requiring localized bipolar contact. Neurosurgical support teams use the fine-tip principle around delicate soft tissue planes and small vessels where controlled hemostasis is required. Plastic and reconstructive teams select the forceps for flap edge control, scar revision, graft bed preparation, facial soft tissue refinement, and microvascular-adjacent hemostasis. Dermatologic teams use the non-stick tips for lesion bed coagulation and margin control after excision. Oral and maxillofacial units use the forceps for gingival hemostasis, mucosal contact, and localized coagulation in compatible bipolar setups. Gynecology and veterinary teams apply the same bipolar workflow for fine bleeding-point control in restricted soft tissue fields.
The 0.5 mm tip size is selected when the operative field requires narrow bipolar contact for small vessels, delicate mucosa, periocular tissue, and fine microsurgical hemostasis. The 0.7 mm option provides slightly broader contact while preserving precise distal control for ENT, dermatology, oral surgery, and plastic surgery workflows. The 1.0 mm size is a balanced option for routine fine bipolar coagulation across ophthalmic-adjacent, ENT, plastic surgery, gynecology support, and veterinary trays. The 1.5 mm option is selected when tissue contact must be broader, including small surface bleeders, flap margins, and soft tissue planes requiring increased distal contact area. The 2.0 mm tip provides the widest contact footprint in this range for broader coagulation around soft tissue surfaces and larger bleeding points. Selection depends on vessel diameter, tissue thickness, field depth, access angle, generator compatibility, and surgeon preference for tip contact width. Hospitals can stock the full range for multi-specialty non-stick bipolar forceps trays.
German stainless steel working components provide corrosion resistance, dimensional stability, spring response, connector reliability, and fine-tip alignment for reusable non-stick bipolar forceps exposed to repeated clinical handling and reprocessing. The black insulated body supports electrosurgical workflow by separating the handling area from the conductive distal contact region and helping tray teams distinguish the instrument from plain stainless thumb forceps. Satin, dull, or mirror finish procurement options support facility documentation and surgical instrument standardization across specialty sets. Reprocessing requires focused attention to the non-stick tips, insulation body, spring arms, shaft transitions, and two-pin connector interface because coagulum, tissue residue, fluid deposits, and insulation wear can affect clinical handling. Cleaning follows facility protocols for reusable electrosurgical accessories, including point-of-use preparation, residue removal, manual cleaning, drying, insulation inspection, connector review, packaging, and sterilization before use. CE marking and ISO 13485 alignment support regulated purchasing documentation for hospitals, clinics, distributors, dental centers, veterinary practices, and international healthcare buyers. FDA-compliant procurement support helps United States channels maintain reusable electrosurgical accessory records, while OEM availability and one-piece ordering support institutional replacement purchasing.
| SKU | PS-1091 |
|---|---|
| Product Name | McPherson Two Pin Bipolar Forceps Non-Stick |
| Price | $34.65 |
| Size/Gauge Variants | 0.5 mm, 0.7 mm, 1.0 mm, 1.5 mm, and 2.0 mm under model PS-1091 |
| Instrument Category | Reusable non-stick bipolar forceps with two-pin connector interface |
| Procedure | Ophthalmic tissue coagulation, ENT mucosal hemostasis, neurosurgical support, plastic surgery flap-edge work, dermatologic lesion bed control, oral soft tissue management, gynecology fine bleeding-point control, veterinary electrosurgical procedures |
| Material | German stainless steel working components with insulated reusable forceps body |
| Finish | Satin, dull, or mirror finish procurement options with black insulated body |
| Sterilization | Reusable; clean, dry, inspect insulation, non-stick bipolar tips, spring arms, shaft transitions, and two-pin connector interface, then sterilize through validated facility protocol before sterile use |
| Instrument Classification | Class I reusable non-stick bipolar forceps electrosurgical accessory |
| Reusable | Yes |
| Certifications | CE & ISO 13485 with FDA-compliant procurement support |
| Warranty | 1-year warranty with return and replacement after-sale support |
| MOQ | 1 piece |
| OEM / Custom Orders | Available for distributor, hospital, clinic, dental, veterinary, and institutional purchasing programs |
| After-Sale Service | Return and replacement support, order tracking assistance, and procurement documentation support |
How do McPherson Two Pin Bipolar Forceps Non-Stick differ from standard McPherson bipolar forceps?
McPherson Two Pin Bipolar Forceps Non-Stick combine McPherson-style fine handling with a non-stick distal contact profile. Standard McPherson bipolar forceps provide localized bipolar coagulation but do not emphasize the same non-stick tip workflow. The non-stick pattern is selected when repeated coagulation and clean distal release are important during fine hemostasis. The two-pin connector interface supports compatibility with appropriate bipolar cable systems used in operating room trays. Both instruments deliver current between two opposing tips for localized coagulation. The main clinical difference is the non-stick contact behavior and connector-specific configuration of the PS-1091 model.
Which McPherson Two Pin Bipolar Forceps Non-Stick tip size should be selected?
The 0.5 mm tip is selected for narrow point coagulation in delicate microsurgical and ophthalmic-adjacent fields. The 0.7 mm size provides slightly broader contact while maintaining precise distal handling. The 1.0 mm option is suitable for routine fine bipolar coagulation across ENT, plastic surgery, dermatology, oral surgery, gynecology support, and veterinary workflows. The 1.5 mm tip is selected when the surgeon needs broader contact around small surface bleeders or flap margins. The 2.0 mm option provides the broadest contact in this product range. Selection depends on vessel diameter, tissue thickness, operative depth, access angle, generator compatibility, and surgeon preference for tip width.
What do CE, ISO 13485, and FDA-compliant procurement mean for this product?
McPherson Two Pin Bipolar Forceps Non-Stick are supplied for healthcare purchasing workflows that require traceable instrument documentation. CE marking supports regulated distribution where European conformity documentation is required. ISO 13485 alignment indicates that the manufacturing quality system follows a recognized medical device framework. FDA-compliant procurement support helps buyers serving United States healthcare channels maintain records for reusable surgical instruments and electrosurgical accessories. Hospitals and clinics can use these references during vendor onboarding, internal product review, and recurring supply approval. Distributors can include PS-1091 in ophthalmic, ENT, dermatology, plastic surgery, oral surgery, gynecology support, neurosurgical support, and veterinary procurement programs.
How are the two-pin connector, insulated body, and non-stick tips used intraoperatively?
The two-pin connector interface links McPherson Two Pin Bipolar Forceps Non-Stick to a compatible bipolar cable and generator setup. The surgeon positions the fine tips around the selected bleeding point or tissue contact area before activation. The spring-action body allows controlled opening, closing, release, and repositioning during repeated hemostatic contact. Bipolar energy passes between the two distal tips during activation, concentrating coagulation at the contacted tissue segment. The black insulated body helps control the working pathway while limiting unintended contact along the forceps body. After the procedure, the non-stick tips, insulation body, spring arms, shaft transitions, and connector interface require inspection before reprocessing and reuse.
How should hospitals, clinics, and distributors manage sterilization and supply?
McPherson Two Pin Bipolar Forceps Non-Stick are intended for reusable electrosurgical tray management under validated facility protocols. After the procedure, the non-stick tips, insulated body, connector end, spring arms, and transition areas require prompt cleaning preparation. The forceps should be dried, inspected for insulation integrity, checked for connector condition, packaged, and sterilized according to the facility’s reusable electrosurgical accessory workflow. Hospitals can stock 0.5 mm, 0.7 mm, 1.0 mm, 1.5 mm, and 2.0 mm variants for ophthalmic-adjacent, ENT, dermatology, plastic surgery, oral surgery, gynecology, neurosurgical support, and veterinary trays. Clinics and distributors can order single units or include the forceps in custom non-stick bipolar instrument sets. Procurement teams receive return and replacement support, order tracking assistance, and documentation support for institutional purchasing.
Order Processing: We strive to serve you promptly! Orders placed before the cut-off time of 5:00 PM (GMT -05:00) (Eastern Standard Time) will be processed the same business day. Orders placed after this time will be processed the next business day.
Handling Time: Our standard handling time is 1-2 business days (Monday through Friday). This includes order verification, quality checks, packaging, and dispatch. Please note that orders placed on weekends or holidays will be processed on the following business day.
Transit Time: Once dispatched, the estimated transit time is 4-5 business days (Monday through Friday). However, transit times may vary depending on your location and any unforeseen circumstances.
Shipping Fee: Enjoy free worldwide shipping on all orders over $250! At Peak Surgical Instruments, we cover all import charges for your convenience.
Customers will receive a tracking ID as soon as their order is dispatched via FedEx or DHL.
We proudly offer worldwide shipping, ensuring that our premium surgical instruments are accessible to healthcare professionals across the globe. No matter where you are, you can count on us to deliver quality tools right to your doorstep!
To provide you with confidence in your purchase, we offer a 1-year warranty as well as a 30-day money-back guarantee on all non-personalized orders.
We understand that delays can be frustrating. Transit times are estimates based on recent orders and may change. If your package is delayed, we will do everything possible to expedite delivery. In case of significant delays or missing packages, we will reship your order at no extra cost to you.
At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.
To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.
Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.
To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.
Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States
No Restocking Fee: We do not charge restocking fees on approved returns.
Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.
Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.
Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.
Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.
Please note that your bank or credit card provider may require additional time to post the refund to your account.
Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.
Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.
For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.
Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.
For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.
For return, refund, or exchange inquiries, please contact us:
Phone: +1 315 526 9968
Email: info@peaksurgicals.com