Skip to content
Featured Collection
PEAK SURGICAL
SKU:
CE Certified
FDA Certified
ISO Certified

Cortex Screw 2.7mm is a stainless steel veterinary orthopedic screw designed for cortical bone purchase, TPLO plate fixation, fracture stabilization, and small fragment orthopedic repair in veterinary surgery. The available variants are Cortex Screw 2.7mm Length 6mm Hex Head, 8mm Hex Head, 10mm Hex Head, 12mm Hex Head, 14mm Hex Head, 16mm Hex Head, 18mm Hex Head, 20mm Hex Head, 22mm Hex Head, 24mm Hex Head, 26mm Hex Head, 28mm Hex Head, and 30mm to 40mm Hex Head. The screw has a 2.7mm diameter, cortical thread profile, pointed tip, and hex head for driver engagement during insertion. It is used with compatible veterinary orthopedic plates in TPLO procedures, compression plate fixation, neutralization plating, corrective osteotomy, small bone stabilization, and selected trauma repairs. Veterinary orthopedic surgeons, small animal practitioners, referral hospitals, teaching institutions, and procurement teams use this screw range in TPLO and orthopedic implant trays where 2.7mm cortical fixation is required.
The 2.7mm cortex screw profile is selected when the operative plan requires a smaller diameter cortical screw for plate fixation and cortical bone engagement. The cortical thread pattern is intended for prepared cortical bone, supporting stable screw purchase when used through compatible plate holes or planned bone corridors. The pointed tip supports entry into the drilled path after depth measurement. The hex head allows engagement with a compatible hex screwdriver, giving the surgeon controlled insertion, alignment, and final seating. Correct driver fit is important because incomplete engagement can damage the head or reduce torque control. During placement, the surgeon maintains axial alignment, advances the screw gradually, monitors resistance, and seats the head according to the plate or fixation plan. Screw length should match measured bone depth, plate thickness, screw trajectory, and intended cortical purchase.
Clinical use begins after radiographic planning, patient positioning, surgical approach, reduction or osteotomy positioning, plate selection, drilling, and depth measurement. In TPLO procedures, Cortex Screw 2.7mm may be selected for compatible plate holes where smaller cortical fixation is required around the tibial construct. In fracture repair, the screw can support compression plates, neutralization plates, bridging constructs, and selected small fragment fixation systems. It may also be used in corrective osteotomy support, periarticular stabilization, and veterinary orthopedic trauma workflows where a 2.7mm cortical screw diameter is appropriate. The surgeon selects the correct screw length after measuring the prepared hole and confirming near cortex, far cortex, plate thickness, and desired screw purchase. Proper placement depends on compatible instrumentation, bone quality, screw trajectory, reduction stability, and the chosen fixation strategy.
The 6mm and 8mm variants are selected for shallow fixation points, small patient anatomy, and compact plate positions where limited screw length is required. The 10mm, 12mm, 14mm, 16mm, 18mm, and 20mm variants support common TPLO and small fragment fixation needs where moderate cortical purchase is planned. The 22mm, 24mm, 26mm, and 28mm options provide additional working length for deeper measured bone corridors. The 30mm to 40mm option supports longer fixation requirements when confirmed by depth measurement and plate position. Keeping the full length range available helps the surgical team respond to intraoperative measurements without changing diameter or head style. Selection should follow drill path, plate thickness, patient size, target cortex, and final verification that the screw seats correctly without unwanted protrusion beyond the intended bone corridor.
Stainless steel construction supports thread integrity, head geometry, shaft strength, and handling during orthopedic tray preparation. Before use, the surgical team should inspect the screw head, threads, tip, and shaft for visible damage, contamination, deformation, or packaging concerns. The hex recess should remain clean and clearly formed so the driver seats fully during insertion. Implant handling should follow facility protocol for sterile transfer, sterilization status, tray organization, documentation, and single-patient surgical use. Procurement teams can standardize Cortex Screw 2.7mm variants with compatible TPLO plates, compression plates, drill bits, taps where applicable, depth gauges, hex screwdrivers, screw racks, and implant storage systems. CE marking, ISO 13485 certification, and FDA compliance language support purchasing documentation for veterinary hospitals, distributors, teaching programs, and institutional buyers. The $3.30 price, OEM availability, carton-box packing, and return and replacement support help maintain orthopedic implant inventory.
| SKU | Not listed in accessible page data |
|---|---|
| Product Name | Cortex Screw 2.7mm |
| Price | $3.30 |
| Size Variants | 6mm, 8mm, 10mm, 12mm, 14mm, 16mm, 18mm, 20mm, 22mm, 24mm, 26mm, 28mm, and 30mm to 40mm Hex Head |
| Instrument Category | Veterinary orthopedic cortex screw |
| Procedure | TPLO plate fixation, cortical bone purchase, fracture stabilization, compression plating, neutralization plating, corrective osteotomy |
| Diameter | 2.7mm |
| Head Type | Hex head |
| Thread Type | Cortical thread profile |
| Material | Stainless steel |
| Implant Handling | Use according to facility implant handling and sterilization protocol |
| Use Profile | Single-patient veterinary orthopedic implant use |
| Certifications | CE marked, ISO 13485 certified, FDA compliant |
| OEM / Custom Orders | Available |
| After-Sale Service | Return and replacement support |
How is Cortex Screw 2.7mm used in veterinary TPLO procedures? Cortex Screw 2.7mm is used when a compatible TPLO plate or orthopedic construct requires smaller diameter cortical screw fixation. After drilling and depth measurement, the surgeon selects the correct length, engages the hex head with a compatible driver, and advances the screw through the plate hole into the prepared cortical bone path. The screw helps secure the plate according to the fixation plan. Final use depends on plate compatibility, patient size, bone quality, screw trajectory, and surgeon judgment.
Which screw length should be selected? Screw length should be selected after intraoperative depth measurement and confirmation of plate thickness, bone diameter, and intended cortical purchase. Shorter 6mm and 8mm options suit shallow fixation points. Mid-range 10mm to 20mm options support many small animal TPLO and plate fixation needs. Longer 22mm to 40mm options are selected when measured bone depth requires additional working length. The surgeon should verify final seating and avoid unwanted protrusion beyond the planned cortex.
How does a 2.7mm cortex screw differ from larger cortical screws? Cortex Screw 2.7mm provides a smaller diameter option for fine orthopedic plate fixation and smaller bone corridors. Larger cortical screws, such as 3.5mm or 4.5mm patterns, are selected when bone size, plate design, and fixation demand require greater diameter. The 2.7mm screw is useful where the plate system and patient anatomy call for smaller cortical purchase. Selection should follow implant compatibility, bone size, screw hole design, and fixation objective.
What driver is required for this screw? This screw uses a hex head and requires a compatible hex screwdriver from the appropriate veterinary orthopedic instrument system. The driver should seat fully before torque is applied. Correct driver fit helps reduce slipping, head damage, and incomplete insertion control. During placement, the surgeon maintains axial alignment, advances the screw gradually, monitors resistance, and stops when the head seats properly against the plate or bone surface.
What role does this screw serve in an orthopedic implant inventory? Cortex Screw 2.7mm provides a small cortical fixation option for TPLO plates, compression plates, small fragment repair, corrective osteotomy, and selected veterinary trauma cases. It is stored with compatible plates, drill bits, taps where applicable, depth gauges, hex screwdrivers, reduction forceps, screw racks, and implant trays. Stocking 6mm to 40mm length options helps the surgical team match screw length to measured bone depth during orthopedic procedures.