Skip to product information
1 of 3

PEAK SURGICALS

90° Right Rotary Arthroscopic Tissue Punch – 2.75 mm Shaft for Angled Joint Resection

90° Right Rotary Arthroscopic Tissue Punch – 2.75 mm Shaft for Angled Joint Resection

SKU:PS-000025

Regular price $71.50 USD
Regular price Sale price $71.50 USD
Sale Sold out
Taxes included. Shipping calculated at checkout.
Quantity
Secure Checkout Protected payment flow
Quality Inspected Checked before dispatch
Worldwide Supply International buyer support
Shipping, Returns & Payments Clear buyer information before checkout.
Shipping
Free shipping on orders over $99. See shipping details
Returns
Returns and exchanges are handled according to our return policy. See return policy
Payments
American Express Apple Pay Diners Club Discover Google Pay JCB Mastercard
View full details

90° Right Rotary Arthroscopic Tissue Punch, SKU PS-000025, is a reusable manual arthroscopy instrument designed for controlled soft-tissue resection where the target lies at an angle to the primary portal and shaft axis. The instrument combines a 90° right rotary working tip with a straight 2.75 mm shaft, an approximate overall length of 6 1/2 in (165 mm), and ergonomic finger-loop handles measuring approximately 1 in (25 mm) in diameter. Its right-oriented rotary tip allows the distal cutting jaws to approach tissue from a perpendicular direction while the main shaft remains comparatively straight within the arthroscopic portal. This configuration is useful during knee, shoulder, and other joint arthroscopy when a conventional straight punch cannot obtain an effective cutting relationship with the selected tissue margin. Surgical-grade stainless steel provides structural rigidity and corrosion resistance for repeated professional use. Peak Surgicals lists PS-000025 as reusable and fully autoclavable and currently offers the instrument at $71.50 for orthopedic and arthroscopic instrument procurement.

90° Right Rotary Tip and Manual Tissue Punch Mechanism

The defining feature of PS-000025 is its 90° right rotary distal working orientation. Rather than positioning the cutting jaws directly in line with the shaft, the right-angle configuration redirects the working end so tissue located perpendicular to the portal trajectory can be engaged without requiring excessive movement of the entire instrument. The straight 2.75 mm shaft maintains a slim profile through the arthroscopic access point while the distal jaw provides the directional change required at the surgical target. Once the intended tissue is visualized and positioned between the working surfaces, controlled closure of the finger-loop handles activates the mechanical cutting jaws. The surgeon determines each resection through tip position, jaw orientation, handle pressure, and continuous arthroscopic visualization. Rotary-tip geometry can improve maneuverability around difficult intra-articular regions, but it does not eliminate the need to protect adjacent cartilage, capsule, ligaments, nerves, vessels, or other structures. Tissue should be removed through measured bites, with the punch repositioned whenever the target direction or required access angle changes.

Knee, Shoulder and Difficult-Angle Arthroscopy Workflow

During knee arthroscopy, a 90° right rotary punch can be selected when unstable meniscal or other soft tissue lies outside the effective bite line of a conventional straight-tip instrument. The 2.75 mm straight shaft is advanced through the selected portal under visualization while the right-angle distal tip is oriented toward the target tissue. Once the cutting jaw is positioned around the intended margin, the surgeon closes the handles to complete a controlled mechanical resection. Sequential small bites can then be used to contour remaining tissue while preserving stable structures. Similar geometry can be useful during shoulder arthroscopy when tissue is located around an angled or recessed area that is difficult to engage directly along the portal axis. Peak Surgicals also positions the instrument for other minimally invasive joint procedures requiring angled access and maneuverability. The rotary design should be used to improve access rather than to force the shaft against surrounding anatomy. Each cut should remain directly visualized, and the working end should be repositioned whenever cartilage, implants, capsule, or other protected structures enter the intended jaw pathway.

PS-000025 2.75 mm Shaft and Right-Rotary Configuration Selection

Peak Surgicals SKU PS-000025 is specifically documented with a 2.75 mm shaft diameter, 90° right rotary tip, straight shaft, and approximately 165 mm overall length. These dimensions are important because arthroscopy punch families include multiple shaft diameters and right, left, straight, curved, reverse, and up-biting configurations that should not be treated as interchangeable. The 2.75 mm profile provides a relatively slim portal footprint while maintaining the working geometry required for mechanical tissue resection. A right rotary tip should be selected when the required cutting direction corresponds to the right-oriented 90° working relationship; a left rotary configuration is needed when access is required from the opposite direction. Arthrex independently documents a 2.75 mm 90° right rotary straight-shaft configuration under catalog AR-11912, demonstrating that this geometry is an established arthroscopy pattern. However, the current Peak page does not publish an original manufacturer catalog number, so PS-000025 should not automatically be relabeled AR-11912. Procurement records should retain the Peak SKU and exact dimensional configuration unless original instrument identification is confirmed.

Surgical Stainless Steel, Autoclaving and Procurement Standards

Surgical-grade stainless steel provides the rigidity, corrosion resistance, and dimensional stability required for a reusable arthroscopic punch exposed to repeated mechanical cycling, cleaning, and steam sterilization. Peak Surgicals identifies PS-000025 as reusable and fully autoclavable. Reprocessing should begin promptly after surgery so blood, synovial material, cartilage fragments, and other tissue debris do not dry within the 90° cutting jaws, rotary mechanism, shaft transition, or finger-loop handle assembly. The distal mechanism should remain accessible during cleaning so all working surfaces and moving interfaces can be thoroughly decontaminated. After rinsing and complete drying, sterile-processing personnel should inspect jaw alignment, cutting-edge condition, rotary movement, shaft straightness, handle operation, corrosion, cracks, or retained contamination. The mechanism should move smoothly without excessive play or binding before the instrument returns to service. Terminal sterilization should follow the healthcare facility's validated protocol and applicable instructions for reusable arthroscopy instrumentation. Peak displays CE, FDA, and ISO certification badges; institutional buyers should maintain exact supplier and device documentation rather than interpreting general storefront badges as proof of individual FDA approval.

SKU PS-000025
Product Name 90° Right Rotary Arthroscopic Tissue Punch
Price $71.50 USD
Overall Length Approximately 6 1/2 in / 165 mm
Shaft Diameter 2.75 mm / 7/64 in
Tip Configuration 90° Right Rotary Tip
Shaft Design Straight Shaft
Finger Loop Diameter Approximately 1 in / 25 mm
Handle Design Ergonomic Finger-Loop Handle
Instrument Category Orthopedic Arthroscopy Tissue Punch
Procedure Knee arthroscopy, shoulder arthroscopy, meniscal tissue resection, and angled intra-articular soft-tissue removal
Material Surgical-Grade Stainless Steel
Finish Not separately specified on the current live product page
Sterilization Fully autoclavable; reprocess according to validated healthcare-facility protocols
Instrument Classification Reusable Manual Arthroscopic Tissue Resection Instrument
Reusable Yes
Reference Configuration Geometry matches the established 2.75 mm 90° right rotary straight-shaft arthroscopy punch pattern; original manufacturer catalog number requires confirmation
Certifications Peak storefront displays CE, FDA, and ISO certification badges; exact device documentation should be verified for procurement
Warranty 30-Day Money-Back Guarantee on eligible purchases
MOQ 1 Piece for standard online ordering
OEM / Custom Orders Available for institutional, distributor, and custom procurement requirements
After-Sale Service Return and replacement support under Peak Surgicals policy

How does the 90° Right Rotary Arthroscopic Tissue Punch differ from a straight arthroscopy punch?
A straight arthroscopy punch keeps the distal cutting jaws aligned with the longitudinal axis of the shaft. The 90° Right Rotary Arthroscopic Tissue Punch redirects the working tip approximately perpendicular to that axis so tissue located to the side of the portal trajectory can be engaged more effectively. This can reduce the amount of shaft manipulation needed when the surgical target cannot be reached directly. A straight punch remains preferable when the tissue lies naturally in line with the working portal. Both instruments perform controlled mechanical tissue resection through manual handle closure. Selection should reflect target location, portal position, desired bite direction, joint anatomy, and surrounding articular structures.

Why is the 2.75 mm shaft important when selecting PS-000025?
The 2.75 mm shaft diameter is an exact specification published for PS-000025 and should remain associated with this product. Arthroscopy punch systems are available with different shaft diameters, including larger 3.4 mm configurations. A smaller shaft profile can provide useful maneuverability through limited arthroscopic access while preserving space for visualization and other instrumentation. Peak Surgicals also carries separate 3.4 mm rotary punch products, so those dimensions should not be merged into this listing. The 2.75 mm measurement also corresponds to an established 90° right rotary straight-shaft instrument configuration in major arthroscopy systems. Hospitals should therefore record the 2.75 mm diameter together with the right rotary tip and Peak SKU when preparing purchase orders or tray inventories.

What do CE, ISO 13485 and FDA references mean for procurement?
Peak Surgicals displays CE, FDA, and ISO certification badges on the PS-000025 product page. ISO 13485 relates to quality-management systems used in controlled medical-device manufacturing and associated processes. CE documentation addresses applicable medical-device conformity requirements within relevant markets. FDA status should be established through the exact manufacturer and device identity rather than inferred solely from a storefront certification badge. Although an established commercial 2.75 mm right rotary punch configuration can be independently identified, the Peak page does not publish an original manufacturer catalog number. Hospitals should retain the Peak SKU, supplier documentation, certificates, and any exact device records required by their procurement and regulatory procedures.

How does the right rotary mechanism improve access during arthroscopy?
The right rotary configuration changes the direction of the distal working jaws relative to the straight shaft. This allows the surgeon to orient the cutting surfaces toward tissue positioned approximately perpendicular to the instrument's main axis. The shaft can therefore remain relatively stable within the portal while the working end addresses a difficult-angle target. Once the jaw is correctly positioned, closure of the finger-loop handles performs the mechanical tissue resection. Rotary geometry improves directional access but does not replace direct arthroscopic visualization or careful protection of surrounding anatomy. The surgeon should use controlled incremental bites and reposition the instrument whenever the tissue orientation changes.

How should hospitals order and reprocess the 90° Right Rotary Arthroscopic Tissue Punch?
Hospitals should order this exact instrument using Peak Surgicals SKU PS-000025 together with the 2.75 mm straight-shaft, 90° right rotary, and approximately 165 mm overall-length specifications. Peak Surgicals currently lists the product at $71.50 and displays a 30-day money-back guarantee. The separate 3.4 mm right or left rotary punch listings should remain distinct procurement items. Following surgery, tissue and synovial debris should be removed promptly from the cutting jaws, rotary mechanism, shaft, and finger-loop handles. Cleaning should be followed by thorough rinsing, complete drying, and inspection of jaw alignment, cutting surfaces, rotary movement, shaft integrity, and handle function. Final autoclave sterilization should follow the healthcare facility's validated reusable arthroscopy-instrument process before PS-000025 returns to clinical service.