Skip to product information

Trephine #5 – 10mm Diameter Surgical Trephine Instrument

SKU: WE-47585
Trephine #5 (10mm Diameter) – Precision Circular Osteotomy & Core Harvesting The professional surgical solution for flawless circular bone cutting and intact tissue plug extraction. The Trephine #5 10mm Diameter...
In stock
Price:
$247.50
  • Secure Checkout

    Secured Checkout Guaranteed.

  • 30 Day's Money Back

    30 Day's Money Back Guaranteed.

  • Free Shipping On 99 $

    Free Shipping on Orders Above 99 $.

Trephine
Trephine #5 – 10mm Diameter Surgical Trephine Instrument
$247.50

Trephine #5 (10mm Diameter) – Precision Circular Osteotomy & Core Harvesting

The professional surgical solution for flawless circular bone cutting and intact tissue plug extraction. The Trephine #5 10mm Diameter is a specialized, high-precision surgical coring instrument engineered to solve the technical challenge of harvesting perfect cylindrical bone grafts or creating clean, round access holes without splintering the surrounding osseous matrix. Featuring an ultra-sharp, serrated, cylindrical cutting edge and a calibrated solid core, this instrument is a mechanical necessity for surgeons performing autologous bone grafting, core biopsies, and corrective reconstructive procedures. Its architecture is explicitly optimized for exceptional axial alignment, enabling the surgeon to harvest dense cortical-cancellous plugs with absolute structural integrity.

Key Features for Professional Medical Management

  • Micro-Serrated 10mm Cylindrical Head: Features a razor-sharp, circular cutting rim with precision-milled saw-teeth. This geometry is a mechanical necessity for initiating clean, circular grooves in cortical bone without skidding, ensuring a smooth, perfectly round boundary.
  • Deep-Coring Cannulated Barrel: Engineered with a hollow cylindrical body to accommodate and protect the tissue plug during penetration. This hollow chamber is a mechanical necessity for extracting uncrushed, chemically intact bone cores or tissue samples for successful graft transplantation or biopsy analysis.
  • High-Leverage T-Style or Knurled Handle: Designed with a robust manual handle configuration that provides maximum rotational grip. This shape is a mechanical necessity for applying a steady, manual twisting force while maintaining strict vertical stability over the operative target.
  • Laser-Etched Depth Graduation Marks: Features clear, indelible millimeter measurement lines along the outer surface of the barrel. These visual indicators are a mechanical necessity for tracking cutting depth in real time, preventing accidental overpenetration or injury to underlying structures.
  • Integrated Core Ejector Slot / Retractable Pin: Built with a specialized lateral window or internal plunger mechanism. This design feature is a mechanical necessity for safely extracting the jammed bone specimen from the barrel without damaging its cellular architecture.
  • Surgical-Grade Stainless Steel Construction: Forged from high-tempered, corrosion-resistant medical steel. This premium alloy selection is a mechanical necessity for preserving the cutting-edge sharpness and preventing tooth deformation through high-frequency vacuum steam sterilization cycles.

Detailed Product Description

The Trephine #5 (10mm Diameter) represents the pinnacle of manual, ultra-controlled circular osteotomy instrumentation. In delicate grafting and diagnostic procedures—such as maxillofacial reconstructions, orthopedic bone core sampling, or neurosurgical access—automated power cutting tools can generate extreme localized heat and torque, often causing thermal necrosis or crumbling the vital architecture of the harvest plug. This hand-driven trephine drill serves as a high-durability mechanical extension of the clinician’s hand, offering tactile, mechanical “depth-braking authority” that power-driven systems cannot match.

At its core, the tool is engineered for clinical longevity and predictable tissue manipulation. By relying entirely on calculated manual rotation, it eliminates friction-induced heat buildup, shielding the fragile osteocytes and vascular spaces within the graft. This intentional thermal defense is a mechanical necessity for promoting optimal graft viability, encouraging rapid post-operative vascularization, and facilitating successful implant osseointegration at the recipient site.

Built to exceed international quality standards for medical instrumentation, this reusable trephine is completely autoclavable and optimized for straightforward debris removal. Its resilient, micro-machined profile makes it an indispensable asset for ensuring safe, organized, and high-precision results in all specialized orthopedic and reconstructive environments.

Specifications & Clinical Applications

Feature Details

Outer Diameter 10.0mm (Size #5 Calibrated)

Cutting Element Micro-Serrated Circular Saw-Teeth

Barrel Type Cannulated (Hollow Core for Plugs)

Handle Architecture High-Traction Ergonomic Grip

Material Body Premium Surgical Stainless Steel

Reprocessing Fully Autoclavable / High-Vacuum Steam-Safe

Certifications CE, ISO, Professional Surgical Grade

Primary Use Cases:

  • Autologous Bone Graft Harvesting: Extracting pristine 10mm cylindrical bone plugs from donor sites like the iliac crest, tibia, or chin for cleft or ridge reconstructions.
  • Core Bone Biopsies: Procuring intact, non-fragmented marrow and cortical samples for histopathological assessment in suspected bone lesions.
  • Implant Site Preparation: Creating perfectly round bony windows or sockets for matching orthopedic or dental hardware components.
  • Circular Access Osteotomy: Executing small, controlled circular entry points in specialized neurosurgical or podiatric procedures.
  • Reconstructive Joint Surgery: Boring out precisely mapped cartilage or bone defects during mosaicplasty cartilage repairs.

Why Professionals Choose the #5 10mm Trephine?

  • Uncompromised Specimen Integrity: The manual coring motion is a mechanical necessity for capturing structurally sound bone plugs without fracturing the delicate cancellous lattice inside.
  • Zero Heat-Induced Necrosis: Eliminates power-drill burning completely, making it a mechanical necessity for preserving live bone tissue and accelerating post-operative healing.
  • Flawless Trajectory Control: The weighted, balanced handle configuration allows the surgeon to apply uniform downward pressure while rotating, a mechanical necessity for maintaining perfect perpendicularity to the bone plane.
  • Streamlined Central Decontamination: The straightforward barrel channel and open-window layout feature no complex internal gears or linkages, serving as a mechanical necessity for absolute sterilization security and fast tray turnarounds.

FAQ Section

Q: Can this trephine be attached to a low-speed surgical handpiece?

A: This specific model is a solid-state manual instrument featuring an integrated handgrip. This configuration is a mechanical necessity for optimizing pure manual control and tactile feel. For power handpieces, a dedicated latch-type or dental connection shank model must be specified.

Q: How do you prevent the bone core from getting stuck inside the barrel?

A: The instrument features a lateral access window or built-in ejector mechanism. Utilizing a fine surgical probe through this slot is a mechanical necessity for smoothly pushing the harvested specimen out from the rear, preventing structural crush injuries to the bone plug.

Q: Is a starter guide required to use this tool?

A: While the sharp saw-teeth are engineered to bite directly into bone, it is a professional standard to utilize a matching surgical drill guide or apply the tool at a slight initial angle ($45^\circ$) to establish a crescent-shaped track before shifting to a full perpendicular ($90^\circ$) stance. This practice is a mechanical necessity for avoiding surface slippage.

Q: How should the micro-serrated teeth be cleaned and preserved?

A: It is a professional standard to use a soft nylon brush during manual pre-cleaning to clear trapped marrow debris from the teeth. Storing the tool in a dedicated silicone holder is a mechanical necessity for preventing metal-on-metal friction that could dull the fine cutting edge.

Q: What are the parameters for steam sterilization?

A: The premium surgical steel construction is a mechanical necessity for heavy clinical reuse and is fully rated to undergo standard high-vacuum steam autoclave cycles at 134°C (273°F) without experiencing corrosion, tooth blunting, or structural decay.

At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.

Eligibility for Returns

To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.

Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.

How to Initiate a Return

To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.

Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States

Return Shipping Costs

No Restocking Fee: We do not charge restocking fees on approved returns.

Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.

Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.

Return Conditions

Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.

Refund Process

Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.

Please note that your bank or credit card provider may require additional time to post the refund to your account.

Damaged, Defective, or Incorrect Items

Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.

Exceptions and Non-Returnable Items

Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.

Exchanges

For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.

Worldwide Shipping

Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.

European Union Customers

For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.

Contact Us

For return, refund, or exchange inquiries, please contact us:

Phone: +1 315 526 9968
Email: info@peaksurgicals.com

Related products