Skip to product information

Distal Radius 2.4 or 2.7mm Plates Stainless Steel – Two-Column Volar ORIF Plate and Screw Set

SKU: PS-OP-002
The Distal Radius 2.4 or 2.7mm Plates Stainless Steel set from Peak Surgicals is a complete two-column volar distal radius plate and screw system in surgical-grade stainless steel, designed for...
In stock
Price:
$2,420.00
  • Secure Checkout

    Secured Checkout Guaranteed.

  • 30 Day's Money Back

    30 Day's Money Back Guaranteed.

  • Free Shipping On 99 $

    Free Shipping on Orders Above 99 $.

Two-Column Distal Radius 2.4 or 2.7MM Plates SS (Standard 22, Wide 25.5) & Screws Set With Instruments
Distal Radius 2.4 or 2.7mm Plates Stainless Steel – Two-Column Volar ORIF Plate and Screw Set
$2,420.00

The Distal Radius 2.4 or 2.7mm Plates Stainless Steel set from Peak Surgicals is a complete two-column volar distal radius plate and screw system in surgical-grade stainless steel, designed for open reduction and internal fixation (ORIF) of distal radius fractures via the volar approach. The set includes 12 two-column volar distal radius plates in Standard 22mm and Wide 25.5mm configurations across left and right orientations and shaft hole counts, a comprehensive screw inventory in 2.4mm variable-angle locking, 2.4mm safety-lock locking, 2.4mm cortex self-tapping, and 2.7mm cortex self-tapping varieties across all clinically required lengths, and a dedicated instrument set for plate application. It is used by orthopedic surgeons and hand surgeons in hospital operating theatres and surgical centers performing distal radius fracture fixation worldwide.

Two-Column Volar Distal Radius Plate Design: Standard and Wide Configurations

The set provides two distinct plate widths to accommodate the anatomical variation in distal radius width encountered across different patient populations. The Standard width plate (22mm, PS-130 series) features 6 head holes and is supplied in left and right orientations with 2-hole, 3-hole, and 4-hole shaft configurations — providing 6 plates in total for this width. The Wide plate (25.5mm, PS-136 series) features 7 head holes and is similarly supplied in left/right orientations with 2/3/4-hole shaft variants — a further 6 plates. The two-column design of the plate provides subchondral support to both the radial and ulnar columns of the distal radius articular surface simultaneously, maintaining reduction of the articular fragments and preventing loss of volar tilt during healing. The safety-lock variable-angle screw holes in the plate head allow intraoperative adjustment of individual screw trajectories within a defined angular range, enabling the surgeon to target specific subchondral bone beneath articular fragments without being constrained to a fixed screw axis.

Screw Inventory: Variable Angle Locking, Safety Lock, Cortex 2.4mm, and Cortex 2.7mm

The set includes four screw categories covering all fixation requirements for volar distal radius plate fixation. The 2.4mm Variable Angle Safety-Lock Screws (PS-100V series, star-drive, stainless steel) are provided in 12 lengths from 8mm to 30mm in 2mm increments, 4 screws per length — a total of 48 screws — for use in the variable-angle locking holes of the plate head to achieve subchondral locking fixation. The 2.4mm Safety Lock Screws (PS-100S series, star-drive, stainless steel) are provided in the same 12 lengths from 8mm to 30mm, 3 screws per length — 36 screws — for fixed-angle locking head hole fixation. The 2.4mm Cortex Screws Self-Tapping (100S series, star-drive, stainless steel) are provided in 12 lengths from 8mm to 30mm, 3 screws per length — 36 screws — for cortical fixation in the plate shaft holes. The 2.7mm Cortex Screws Self-Tapping (101S series, star-drive, stainless steel) are provided in 11 lengths from 10mm to 30mm, 3 screws per length — 33 screws — as an alternative cortex shaft screw for use in the 2.7mm shaft holes where the cortical bone dimension warrants the larger diameter.

Instrument Set for Plate Application

The instrument component of the set supports the complete ORIF workflow for volar distal radius plate fixation: the Depth Gauge (PS.431.01) measures screw length accurately before screw selection to prevent over-length screws from penetrating the dorsal cortex or entering the radiocarpal joint; the Star Screwdriver Shaft Short (PS.431.02) and Star Screwdriver Shaft Long (PS.431.03) accommodate the star-drive screw head in both accessible and constrained access situations; the Drill Bit 1.8mm (PS.431.04) prepares pilot holes for 2.4mm screws; the Drill Bit 2.0mm (PS.431.05) prepares standard cortex screw pilot holes; and the Drill Bit 2.0mm Long (PS.431.06) provides extended reach for drilling trajectories in deeper subchondral positions. Additional instruments are included in the set — confirm the complete instrument list in the Shopify admin for any items not visible in the product table.

Stainless Steel Construction and Surgical-Grade Compliance

All plates, screws, and instruments in the set are manufactured from surgical-grade stainless steel, providing the corrosion resistance, dimensional stability, and mechanical strength required for implanted orthopedic fixation devices and the instruments used to apply them. Stainless steel distal radius plates are widely used in hand and wrist surgery for their established clinical track record, implant availability, and compatibility with standard orthopedic instrument systems. All implants and instruments are compatible with standard autoclave sterilization protocols used in licensed surgical facilities.

CE Mark, ISO 13485, and FDA Certification for Orthopedic Implant Procurement

The Distal Radius 2.4 or 2.7mm Plates Stainless Steel set is manufactured under CE Mark, ISO 13485, and FDA compliant quality standards. ISO 13485 certification confirms Peak Surgicals operates a documented quality management system covering design control, material traceability, and production consistency for orthopedic implants and surgical instruments. CE Mark confirms conformity with European medical device regulations, and FDA compliance supports procurement for US-based hospitals, surgical centers, and hand surgery departments requiring verified regulatory documentation for implant and instrument set purchases.

Product Specifications

SKU — (verify in Shopify admin)
Product Name Two-Column Distal Radius 2.4/2.7mm Plates SS (Standard 22, Wide 25.5) & Screws Set With Instruments
Price $2,420.00 USD
Instrument Category Orthopedic — Hand Surgery / Distal Radius ORIF
Procedure Open reduction internal fixation (ORIF) of distal radius fractures via volar approach
Material Surgical-Grade Stainless Steel
Plate Design Two-column volar distal radius plate — safety-lock variable-angle head holes
Standard Plates (PS-130 series) Width 22mm, 6 head holes — Left/Right × 2/3/4 shaft holes = 6 plates
Wide Plates (PS-136 series) Width 25.5mm, 7 head holes — Left/Right × 2/3/4 shaft holes = 6 plates
Total Plates 12 plates
2.4mm Variable Angle Locking Screws Lengths 8–30mm (×4 each, 12 lengths) = 48 screws (PS-100V series)
2.4mm Safety Lock Screws Lengths 8–30mm (×3 each, 12 lengths) = 36 screws (PS-100S series)
2.4mm Cortex Self-Tapping Screws Lengths 8–30mm (×3 each, 12 lengths) = 36 screws (100S series)
2.7mm Cortex Self-Tapping Screws Lengths 10–30mm (×3 each, 11 lengths) = 33 screws (101S series)
Screw Drive Star-drive (Torx-type)
Instruments Depth Gauge, Star Screwdriver Short, Star Screwdriver Long, Drill Bit 1.8mm, Drill Bit 2.0mm, Drill Bit 2.0mm Long (+ additional instruments — confirm in admin)
Certifications CE Mark, ISO 13485, FDA
Warranty 1 Year
MOQ 1 Set
OEM / Custom Orders Available
After-Sale Service Return and Replacement

Frequently Asked Questions

What is a two-column volar distal radius plate and why is it used for distal radius fractures?
The distal radius has two articular columns — the radial column supporting the scaphoid fossa and the ulnar column supporting the lunate fossa — each of which must be anatomically reduced and supported to restore normal wrist mechanics after a fracture. Two-column volar distal radius plates are designed with a plate head geometry that spans both columns simultaneously, providing subchondral support screws under both articular surfaces from a single plate. Volar plate fixation is now the dominant technique for surgical distal radius fractures because the volar surface of the distal radius provides a flat surface suited to plate contouring, the volar approach through the flexor carpi radialis corridor provides excellent exposure with minimal soft tissue disruption, and the subchondral screws can be placed under fluoroscopic guidance with the plate stabilizing the reduction while the screws are inserted.

What is the difference between the Standard 22mm and Wide 25.5mm plate configurations?
The two plate widths in this set address the anatomical variation in distal radius width between patients. The Standard 22mm plate (PS-130 series, 6 head holes) fits the majority of adult wrists and is typically the first choice for normal-sized radii. The Wide 25.5mm plate (PS-136 series, 7 head holes) is required for patients with a wider distal radius — commonly larger males, or radii with fracture patterns involving a wider articular surface — where the standard plate width would leave one column under-supported. Having both widths in the same set allows intraoperative selection without needing a separate implant order if the standard plate is found to be insufficient at the time of surgery.

What is the purpose of variable-angle locking screws versus standard locking screws in a distal radius plate?
Fixed-angle locking screws engage the threaded locking holes of the plate head at a defined, predetermined trajectory. Variable-angle locking screws (PS-100V series in this set) are designed with a mechanism that allows the screw to be inserted at an angle that deviates from the perpendicular within a defined range — typically ±15° — before locking. This angular freedom allows the surgeon to redirect individual subchondral screws intraoperatively to target a specific articular fragment, avoid a comminuted zone, or optimise screw purchase in bone of variable quality, without changing the plate. In osteoporotic bone or complex intraarticular fracture patterns, variable-angle locking significantly increases the surgeon's ability to achieve stable subchondral fixation compared to fixed-angle systems.

What screw lengths should I expect to use in distal radius fixation?
Subchondral head screws in distal radius fixation typically range from 10mm to 18mm depending on the column depth and the position of the articular surface below the plate. Shaft screws for cortical fixation in the radial diaphysis typically range from 12mm to 26mm depending on the cortical thickness and the distance from the plate to the far cortex. The depth gauge (PS.431.01) in this set measures the exact screw length required for each hole after drilling, preventing overshooting the far cortex or entering the radiocarpal joint with a head screw. The set's screw inventory from 8mm to 30mm across all four screw types covers the complete length range required for both subchondral and shaft fixation in adult distal radius ORIF.

What certifications does this set carry?
The Distal Radius 2.4 or 2.7mm Plates Stainless Steel set is manufactured under CE Mark, ISO 13485, and FDA compliant quality standards. ISO 13485 certification confirms Peak Surgicals operates a documented quality management system covering design control, material traceability, and manufacturing consistency for orthopedic implants and instruments. CE Mark confirms conformity with European medical device regulations, and FDA compliance supports procurement for US hospitals, surgical centers, and hand surgery departments requiring verified regulatory documentation.

Can individual plates or screws be ordered as replacements or in custom configurations?
Individual plates by reference number (PS-130 and PS-136 series) and individual screw lengths (PS-100V, PS-100S, 100S, 101S series) are available from Peak Surgicals as replacement items. OEM manufacturing and custom set configurations are also available for hospital procurement departments and orthopedic distributors requiring specific plate geometry modifications, titanium material alternatives, extended screw length ranges, or custom packaging. Contact Peak Surgicals directly for replacement implant pricing, OEM specifications, or institutional procurement arrangements.

At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.

Eligibility for Returns

To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.

Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.

How to Initiate a Return

To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.

Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States

Return Shipping Costs

No Restocking Fee: We do not charge restocking fees on approved returns.

Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.

Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.

Return Conditions

Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.

Refund Process

Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.

Please note that your bank or credit card provider may require additional time to post the refund to your account.

Damaged, Defective, or Incorrect Items

Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.

Exceptions and Non-Returnable Items

Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.

Exchanges

For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.

Worldwide Shipping

Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.