Skip to product information

Cortex Bone Screw 3.5mm Titanium Self-Tapping Hex Head for TPLO Fixation

Cortex Bone Screw 3.5mm Length Self-Tapping Hex Head Titanium is a veterinary orthopedic implant screw designed for TPLO plate fixation, cortical bone purchase, fracture stabilization, and corrective osteotomy work in...
In stock
Price:
$2.20
  • Secure Checkout

    Secured Checkout Guaranteed.

  • 30 Day's Money Back

    30 Day's Money Back Guaranteed.

  • Free Shipping On 99 $

    Free Shipping on Orders Above 99 $.

Cortex Bone Screw 3.5mm Titanium Self-Tapping Hex Head for TPLO Fixation
Regular price $2.20
Regular price Sale price $2.20 (-0%)
Size: Cortex Bone Screw 3.5mm Length 08mm Self-Tapping Hex Head Titanium
Cortex Bone Screw 3.5mm Length Self-Tapping Hex Head Titanium
Cortex Bone Screw 3.5mm Titanium Self-Tapping Hex Head for TPLO Fixation
$2.20

Cortex Bone Screw 3.5mm Length Self-Tapping Hex Head Titanium is a veterinary orthopedic implant screw designed for TPLO plate fixation, cortical bone purchase, fracture stabilization, and corrective osteotomy work in canine orthopedic surgery. The available length variants are 08mm, 10mm, 12mm, 14mm, 16mm, 18mm, 20mm, 22mm, 24mm, 26mm, 28mm, 30mm, 32mm, 34mm, 36mm, 38mm, and 40mm, giving the surgeon a broad range for plate placement and bicortical engagement. The screw has a 3.5mm cortical profile, self-tapping thread geometry, titanium construction, and a hex head drive interface for controlled insertion with compatible orthopedic drivers. It is used during TPLO procedures, veterinary plate fixation, long-bone repair, metaphyseal fixation, compression or neutralization plate application, and orthopedic revision planning. Veterinary orthopedic surgeons, small animal surgical teams, referral hospitals, teaching laboratories, and procurement teams use this screw family in TPLO implant sets and orthopedic screw inventories where accurate length matching is required.

3.5mm Titanium Body, Self-Tapping Thread, and Hex Head Drive

The 3.5mm titanium cortex screw works through a self-tapping thread profile that advances into prepared cortical bone while forming its own thread path during insertion. The hex head accepts a compatible driver, allowing controlled torque transfer, stable seating, and accurate screw advancement through a veterinary orthopedic plate. Titanium construction supports lightweight implant handling and corrosion resistance within orthopedic inventory systems. The cortical thread pattern is intended for firm engagement in dense cortical bone, making it suitable for TPLO plate fixation and other veterinary plate constructs where screw purchase is central to stability. The self-tapping design reduces the need for a separate tapping step when the surgeon determines that bone quality, pilot preparation, and implant protocol support direct advancement. The head profile seats against the plate hole as the shaft engages bone, helping the plate remain positioned during fixation. Proper use follows surgeon preference, implant system compatibility, drill guide selection, pilot hole preparation, depth measurement, and facility implant handling protocol.

TPLO Plate Fixation, Cortical Purchase, and Orthopedic Stabilization

Clinical use begins after orthopedic assessment, radiographic planning, implant selection, and preparation of the operative site. During TPLO surgery, the screw is selected to secure the plate to the tibia after osteotomy positioning and plate contour confirmation. The self-tapping thread helps the screw advance through the prepared pilot hole and engage cortical bone, while the hex head permits measured driver control during final seating. In fracture stabilization, the screw may be used with compatible plates where 3.5mm cortical fixation is appropriate for patient size, bone stock, and surgical plan. During compression or neutralization plating, length selection is matched to plate thickness, near cortex, far cortex, and desired purchase without excessive projection. Veterinary surgeons use these screws with drill bits, depth gauges, hex drivers, reduction forceps, plate benders, and compatible TPLO plates. Final selection depends on anatomy, plate system, planned fixation points, bone quality, and intraoperative measurement rather than image appearance alone.

08mm to 40mm Length Selection for Veterinary Plate Constructs

The 08mm to 40mm variant range allows the surgical team to match screw length to different plate holes, tibial regions, cortical thicknesses, and patient sizes. Shorter lengths such as 08mm, 10mm, 12mm, and 14mm are selected where limited bone depth or plate position requires controlled shallow purchase. Mid-range lengths such as 16mm through 28mm support common cortical fixation points in veterinary orthopedic plating when bicortical engagement is planned and confirmed by measurement. Longer lengths from 30mm through 40mm are selected for deeper trajectories, larger patient anatomy, or plate positions requiring extended bone purchase. The surgeon measures each hole with a depth gauge after drilling and selects the length that matches the construct without unnecessary prominence beyond the far cortex. Keeping the complete range in inventory helps the team avoid compromising fixation because a needed length is missing. Variant selection follows drilled depth, plate thickness, bone contour, screw trajectory, and the fixation role of each hole.

Titanium Implant Handling, Inspection, and Procurement Documentation

This screw is handled as a single-patient veterinary orthopedic implant and should be managed according to facility implant handling, inspection, packaging, and sterilization protocol. Titanium implant storage should protect the screw threads, head geometry, and drive recess from contamination, deformation, or surface damage before use. Before placement, the surgical team confirms diameter, length, thread condition, head compatibility, and package status against the planned implant list. The nonpowered implant profile fits TPLO and orthopedic screw inventories used by veterinary hospitals, referral centers, distributors, and teaching programs. CE marking, ISO 13485 certification, and FDA compliance support procurement documentation for regulated purchasing environments. The $2.20 price point supports length-range stocking where multiple screw sizes are needed for case preparation. OEM availability, return and replacement support, carton-box packing, and one-piece MOQ help clinics and distributors maintain predictable screw supply for titanium self-tapping cortex screw systems used in veterinary orthopedic procedures.

SKU Not listed in accessible Peak listing
Product Name Cortex Bone Screw 3.5mm Length Self-Tapping Hex Head Titanium
Price $2.20
Size Variants 08mm, 10mm, 12mm, 14mm, 16mm, 18mm, 20mm, 22mm, 24mm, 26mm, 28mm, 30mm, 32mm, 34mm, 36mm, 38mm, 40mm
Diameter 3.5mm
Instrument Category Veterinary titanium self-tapping cortex screw
Procedure TPLO plate fixation, cortical bone purchase, fracture stabilization, corrective osteotomy, compression plating, neutralization plating
Material Titanium
Head Type Hex head
Thread Type Self-tapping cortical thread profile
Use Profile Single-patient veterinary orthopedic implant use
Implant Handling Use according to facility implant handling and sterilization protocol
Certifications CE marked, ISO 13485 certified, FDA compliant
MOQ 1 piece
OEM / Custom Orders Available
After-Sale Service Return and replacement support

How is the Cortex Bone Screw 3.5mm Titanium used in TPLO surgery? The screw is used with compatible TPLO plates to secure the plate to the tibia after osteotomy positioning and plate alignment. The surgeon drills the pilot hole, measures depth, selects the proper length, and advances the self-tapping screw with a compatible hex driver. The thread engages cortical bone while the head seats into the plate hole. This supports plate stability during veterinary TPLO fixation when implant selection matches patient anatomy and surgical planning.

Which length should be selected from the 08mm to 40mm range? Length selection is based on drilled depth, plate thickness, bone contour, near cortex, far cortex, and the desired purchase at each plate hole. Shorter screws suit shallow fixation points, while longer screws are selected for deeper trajectories or larger patient anatomy. The surgeon confirms length with a depth gauge rather than relying on plate position alone. Stocking the full range helps the team match each hole accurately during TPLO and orthopedic plating procedures.

How does the titanium version compare with stainless steel cortex screws? The titanium version provides a lightweight implant option for veterinary orthopedic plating systems where titanium implant inventory is preferred. Stainless steel screws are also common in orthopedic sets, but implant material should be matched to the plate system, surgeon preference, procurement policy, and case plan. Titanium and stainless steel implants should not be mixed casually unless the implant system and clinical protocol support that choice. Selection follows compatibility, documentation, and facility standards.

What is the advantage of a self-tapping hex head screw? A self-tapping screw can form its thread path during insertion after pilot hole preparation, reducing the need for a separate tapping step when the surgeon determines that direct advancement is appropriate. The hex head provides controlled driver engagement and torque transfer during placement. This design is useful in TPLO and plate fixation workflows where efficient insertion, stable seating, and accurate length selection are important. Bone quality and implant protocol still guide final use.

What role does this screw serve in a veterinary orthopedic implant inventory? Cortex Bone Screw 3.5mm Length Self-Tapping Hex Head Titanium serves as a core titanium screw option for TPLO sets, cortical fixation trays, fracture repair inventories, and orthopedic implant cabinets. The 08mm to 40mm range lets clinics prepare for varied plate holes and patient sizes without interrupting surgery for missing lengths. Procurement teams stock it with compatible plates, drill bits, depth gauges, hex drivers, and implant organizers so surgeons can select the required screw during planned orthopedic procedures.

At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.

Eligibility for Returns

To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.

Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.

How to Initiate a Return

To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.

Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States

Return Shipping Costs

No Restocking Fee: We do not charge restocking fees on approved returns.

Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.

Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.

Return Conditions

Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.

Refund Process

Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.

Please note that your bank or credit card provider may require additional time to post the refund to your account.

Damaged, Defective, or Incorrect Items

Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.

Exceptions and Non-Returnable Items

Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.

Exchanges

For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.

Worldwide Shipping

Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.

European Union Customers

For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.

Contact Us

For return, refund, or exchange inquiries, please contact us:

Phone: +1 315 526 9968
Email: info@peaksurgicals.com

Related products

Recently viewed products