Skip to content
Couldn't load pickup availability
Secured Checkout Guaranteed.
30 Day's Money Back Guaranteed.
Free Shipping on Orders Above 99 $.

News Suture Scissor, SKU PS-2682, model PS-2682, is a reusable suture-removal scissor manufactured from German stainless steel for controlled cutting of skin sutures, oral sutures, fine ligature ends, dressing material, and closure-stage thread during postoperative wound review. The listed size is Angled on flat 5 1/2", giving clinicians a compact angled profile for approaching stitch lines across skin, mucosa, facial wounds, dental surgical sites, and small operative fields. The image shows angled-on-flat blades, rounded distal ends, a screw-joint pivot, slim shanks, and ring handles for fingertip closure. General surgeons, plastic surgeons, dermatologic surgeons, dental surgeons, ENT teams, gynecology clinicians, emergency physicians, wound-care nurses, veterinary clinicians, and operating room staff use this pattern during interrupted suture removal, mattress suture removal, oral mucosal stitch removal, laceration follow-up, biopsy site care, drain-site review, dressing change, skin closure inspection, and minor procedure room wound management in hospitals, clinics, dental units, emergency departments, wards, veterinary practices, and reusable dressing trays.
The instrument works through two opposing blades joined by a screw-joint pivot that transfers ring-handle compression into controlled distal cutting movement. The angled-on-flat blade geometry lets the operator keep the handle lower while the distal end approaches a suture line close to the skin or mucosal surface. This profile is useful when gauze edges, adhesive dressings, forceps, or wound contours limit the angle available for a straight scissor. The rounded distal ends reduce point pressure during close work around healed incision margins, oral mucosa, facial closures, and small animal skin wounds. The upper cutting edge divides the selected thread once the stitch loop is elevated or tensioned with forceps. Slim shanks keep the hand clear of the wound margin while allowing short progressive closures. Ring handles provide thumb and finger control, while the index finger stabilizes the shaft for precise direction. The screw joint maintains blade alignment so the cutting edges meet consistently. There is no ratchet, spring, or locking catch, so control depends on visual placement, suture tension, blade angle, and fingertip pressure.
During postoperative follow-up, the clinician exposes the wound, identifies the stitch pattern, lifts the thread with forceps, and positions the angled distal blade close to the knot or visible loop. The scissor cuts the suture so the remaining segment can be withdrawn without dragging contaminated external thread through the tissue tract. In dermatologic surgery, it supports removal after excision, biopsy closure, flap repair, scar revision, and facial wound management. In dental and oral surgery, the compact working end helps access gingival sutures, extraction-site closures, implant flap sutures, frenectomy repairs, and mucosal wound margins. ENT and plastic surgery teams use the pattern around auricular, nasal, eyelid-adjacent, and facial closures where hand clearance and low-angle access matter. Emergency departments use it for laceration follow-up, wound checks, and dressing replacement. Veterinary clinicians can apply the same geometry during small animal postoperative skin closure review. The instrument is used after the suture is visible and separated from the wound surface, keeping the blade path controlled throughout the removal sequence.
The Angled on flat 5 1/2" size is selected when the clinician needs more reach than a compact iris-style scissor while retaining close control for stitch removal. This size fits routine wound-care trays, dental surgical packs, outpatient procedure rooms, emergency follow-up stations, dermatology setups, and veterinary minor surgery kits. The 5 1/2" length gives enough shaft clearance to work around gauze, forceps, adhesive dressing edges, and small wound contours without placing the hand directly over the closure line. The angled-on-flat design is selected when a straight suture scissor would require excessive wrist elevation or collide with the dressing surface. It is suitable for skin sutures on the face, limb, abdomen, scalp, and trunk, as well as oral mucosal sutures where a low approach improves access. The single listed configuration simplifies procurement because one size covers routine stitch removal and minor dressing cutting. Selection depends on wound location, stitch spacing, patient size, glove use, and whether the operator needs low-angle access across a flat or slightly curved surface.
German stainless steel supports repeated clinical use by maintaining blade stability, corrosion resistance, and smooth pivot movement through cleaning and steam sterilization cycles. Satin, dull, and mirror finish options allow procurement teams to match surface preference with glare control, inspection workflow, and existing dressing or minor surgery trays. After use, the blades should be opened and cleared of suture fragments, blood, tissue residue, gauze fibers, adhesive debris, and dressing material before enzymatic cleaning. Processing can include manual brushing, ultrasonic decontamination, washer-disinfector exposure, rinsing, drying, pivot inspection, edge review, packaging, and steam autoclave sterilization according to facility protocol. The angled distal section and screw joint require careful inspection because retained thread or dried residue can reduce smooth closure and affect stitch engagement. CE marking, ISO 13485 documentation, and FDA procurement context support purchasing records for hospitals, clinics, dental units, veterinary facilities, distributors, emergency departments, and teaching programs. Class I classification, reusable construction, carton-box packing, 1-piece MOQ, OEM availability, 1-year warranty, and return and replacement service support routine replacement ordering.
| SKU | PS-2682 |
|---|---|
| Product Name | News Suture Scissor |
| Price | $6.05 |
| Size/Gauge Variants | Angled on flat 5 1/2" |
| Instrument Category | Reusable suture-removal and dressing scissor |
| Procedure | Interrupted suture removal, mattress suture removal, oral mucosal stitch removal, laceration follow-up, biopsy site care, drain-site review, dressing change, skin closure inspection, minor wound-care review |
| Material | German stainless steel |
| Finish | Satin, dull, or mirror finish |
| Sterilization | Reusable instrument suitable for manual cleaning, ultrasonic decontamination, washer-disinfector processing, drying, pivot inspection, packaging, and steam autoclave sterilization |
| Instrument Classification | Class I reusable surgical instrument |
| Reusable | Yes |
| Certifications | CE, ISO 13485, FDA |
| Warranty | 1 year |
| MOQ | 1 piece |
| OEM / Custom Orders | Available for distributor supply, institutional branding, bulk purchasing, and customized packing programs |
| After-Sale Service | Return and replacement support for eligible orders |
How is News Suture Scissor different from Littauer Stitch Scissor?
Littauer Stitch Scissor is the closest alternative because it is also used for suture removal. Littauer scissors usually use a hooked blunt lower tip that captures and lifts a stitch loop before cutting. News Suture Scissor uses an angled-on-flat blade profile for low-angle access across stitch lines and dressing edges. This makes it useful when the clinician wants a flatter approach rather than a hook-led capture motion. Both instruments use ring handles and a screw-joint pivot. The clinically relevant difference is the distal working geometry: angled flat scissor access versus hooked suture engagement. Selection depends on wound location, stitch visibility, dressing position, and the operator’s preferred method for lifting the thread.
How should the 5 1/2 inch angled-on-flat size be selected?
The 5 1/2" size is selected for routine postoperative stitch removal where the wound is accessible but hand clearance still matters. It is useful for facial sutures, limb wounds, abdominal closures, biopsy sites, dental mucosal sutures, and veterinary skin closures. The angled-on-flat profile helps the distal blade approach the thread without forcing the handle upward over the wound surface. News Suture Scissor is appropriate when a compact straight scissor would crowd the dressing or require an awkward wrist angle. The length also gives enough reach to work around gauze, forceps, adhesive edges, and small wound contours. Selection depends on stitch spacing, wound site, dressing thickness, glove use, and whether the operator needs a low flat entry line.
What do CE, ISO 13485, and FDA details mean for procurement?
CE documentation supports international conformity records for reusable medical instrument purchasing. ISO 13485 indicates manufacturing under a medical device quality management system covering production control, inspection, and traceability. FDA procurement context supports U.S. purchasing files for Class I reusable surgical instruments. News Suture Scissor can be entered into hospital, clinic, dental, veterinary, emergency department, and distributor catalogs with documented material, finish, size, warranty, MOQ, OEM availability, and after-sale service. These records help purchasing officers, receiving teams, and sterile processing departments align the item with internal approval requirements. The certification profile supports tender files, replacement stock, wound-care trays, and standardized suture-removal kits.
How does the angled blade and screw-joint pivot control suture cutting?
The angled-on-flat blade is the access-control feature because it lets the working end approach the stitch line while the handle stays low. The screw-joint pivot transfers ring-handle pressure into blade closure and keeps the cutting edges aligned. During use, the clinician lifts or tensions the suture, positions the rounded distal end close to the loop or knot, and closes the handles with measured pressure. The cutting edge divides the thread while the angled profile helps maintain visibility across the wound surface. News Suture Scissor does not use a ratchet, spring, or locking catch, so control depends on visual placement, thread tension, blade angle, and fingertip pressure. Cleaning around the pivot and distal blade section is important because retained thread fragments or dried blood can alter handling.
Is this instrument suitable for reusable sterile processing and distributor stock?
Yes, News Suture Scissor is a reusable German stainless steel instrument suitable for hospital, clinic, dental, emergency, veterinary, distributor, and operating room supply workflows. After use, the blades and screw joint should be opened and inspected so suture fragments, adhesive residue, gauze fibers, blood, and topical dressing material can be removed before sterilization. Processing can include manual cleaning, ultrasonic decontamination, washer-disinfector exposure, drying, pivot inspection, packaging, and steam autoclaving. The 1-piece MOQ supports replacement ordering for small clinics, first-aid kits, procedure rooms, wound-care carts, and dental surgical packs. OEM availability supports distributor branding, institutional packing, and bulk purchasing programs. The 1-year warranty and return and replacement service support procurement teams managing recurring suture-scissor inventory.
Order Processing: We strive to serve you promptly! Orders placed before the cut-off time of 5:00 PM (GMT -05:00) (Eastern Standard Time) will be processed the same business day. Orders placed after this time will be processed the next business day.
Handling Time: Our standard handling time is 1-2 business days (Monday through Friday). This includes order verification, quality checks, packaging, and dispatch. Please note that orders placed on weekends or holidays will be processed on the following business day.
Transit Time: Once dispatched, the estimated transit time is 4-5 business days (Monday through Friday). However, transit times may vary depending on your location and any unforeseen circumstances.
Shipping Fee: Enjoy free worldwide shipping on all orders over $250! At Peak Surgical Instruments, we cover all import charges for your convenience.
Customers will receive a tracking ID as soon as their order is dispatched via FedEx or DHL.
We proudly offer worldwide shipping, ensuring that our premium surgical instruments are accessible to healthcare professionals across the globe. No matter where you are, you can count on us to deliver quality tools right to your doorstep!
To provide you with confidence in your purchase, we offer a 1-year warranty as well as a 30-day money-back guarantee on all non-personalized orders.
We understand that delays can be frustrating. Transit times are estimates based on recent orders and may change. If your package is delayed, we will do everything possible to expedite delivery. In case of significant delays or missing packages, we will reship your order at no extra cost to you.
At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.
To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.
Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.
To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.
Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States
No Restocking Fee: We do not charge restocking fees on approved returns.
Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.
Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.
Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.
Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.
Please note that your bank or credit card provider may require additional time to post the refund to your account.
Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.
Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.
For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.
Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.
For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.
For return, refund, or exchange inquiries, please contact us:
Phone: +1 315 526 9968
Email: info@peaksurgicals.com