Skip to product information

Metzenbaum Dissecting Cutting Scissors for 20-28cm Soft-Tissue Dissection

SKU: PS-O T-01013
Metzenbaum Dissecting Cutting Scissors, SKU PS-OT-01013, are reusable surgical dissecting scissors manufactured from German stainless steel for controlled soft-tissue dissection, fascia refinement, mucosal trimming, fibrous band division, and closure-stage operating...
In stock
Price:
$10.01
  • Secure Checkout

    Secured Checkout Guaranteed.

  • 30 Day's Money Back

    30 Day's Money Back Guaranteed.

  • Free Shipping On 99 $

    Free Shipping on Orders Above 99 $.

Metzenbaum Dissecting Cutting Scissors for 20-28cm Soft-Tissue Dissection
Regular price $10.01
Regular price Sale price $10.01 (-0%)
Size: PS-2661 Overall length 9" (23cm)
Metzenbaum Dissecting Cutting Scissors
Metzenbaum Dissecting Cutting Scissors for 20-28cm Soft-Tissue Dissection
$10.01

Metzenbaum Dissecting Cutting Scissors, SKU PS-OT-01013, are reusable surgical dissecting scissors manufactured from German stainless steel for controlled soft-tissue dissection, fascia refinement, mucosal trimming, fibrous band division, and closure-stage operating room cutting. The available variants are PS-2660 with 8" (20cm) overall length, PS-2661 with 9" (23cm) overall length, PS-2662 with 10" (25cm) overall length, and PS-2663 with 11" (28cm) overall length. The image shows long curved blunt blades, a screw-joint pivot, extended shanks, ring handles, and an inset distal blade view for identifying the rounded atraumatic tip profile. General surgeons, gynecology teams, plastic surgeons, ENT surgeons, oral and maxillofacial surgeons, colorectal surgeons, veterinary surgeons, and operating room staff use this pattern during laparotomy, hysterectomy access, hernia repair, wound revision, superficial adhesiolysis, flap undermining, mucosal edge adjustment, scar revision, biopsy margin refinement, suture cutting, and closure-stage soft-tissue management in hospitals, surgical centers, clinics, dental operating rooms, veterinary theaters, teaching labs, and reusable surgical trays.

Curved Blunt Blade Geometry and Screw-Joint Dissection Control

The working mechanism uses two slender curved blades joined by a screw-joint pivot that transfers ring-handle compression into controlled distal closure. The curved profile allows the lower blade to pass beneath elevated soft tissue, fascia, mucosa, scar strands, peritoneal folds, or flap margins while the upper blade completes the cut from an oblique approach. Rounded blunt tips reduce point pressure when the instrument moves near delicate tissue planes, allowing progressive dissection rather than aggressive penetration. The elongated shanks keep the operator’s hand away from retractors, suction, forceps, clamps, packs, and assistant instruments. Ring handles provide thumb and ring-finger purchase, while the index finger stabilizes the shank and guides blade orientation. The screw joint maintains blade alignment so the cutting edges meet predictably during short controlled closures. There is no ratchet, spring, or locking catch, so each cut depends on fingertip pressure, tissue traction, blade angle, and direct visualization. This geometry is selected for soft-tissue planes rather than dense fascia, bone, wire, or instrument-resistant material.

Soft-Tissue Dissection Across General and Specialty Surgery

During open general surgery, the scissors assist after scalpel entry by separating superficial soft tissue, trimming fascial margins, dividing fine fibrous strands, and refining wound edges before closure. In gynecology, the curved blades support soft-tissue adjustment during hysterectomy, cesarean section wound management, pelvic exposure, and closure-stage tissue refinement. Plastic surgery teams use the pattern for flap undermining, scar revision, skin-edge contouring, graft-bed preparation, and small fibrous band division after the plane has been developed. ENT and oral surgery teams can apply the longer variants around mucosal margins, tonsillar pillar remnants, intraoral flaps, and biopsy edges where a broader Mayo pattern would engage excess tissue. Colorectal and abdominal teams use the scissors for peritoneal edge adjustment and superficial adhesiolysis after tissues are lifted with forceps or retracted safely. Veterinary surgeons can place the same pattern in soft-tissue trays for abdominal, wound, oral, and reconstructive procedures. The cutting stage is performed after the target plane is exposed and stabilized, keeping the blade path away from vessels, nerves, ducts, and deeper structures outside the selected line.

20cm, 23cm, 25cm, and 28cm Model Selection

PS-2660 with 8" (20cm) overall length is selected for compact operating fields, superficial wound revision, minor procedure rooms, oral soft-tissue work, scar refinement, and veterinary cases where close hand control is required. PS-2661 with 9" (23cm) length gives added reach for routine general surgery, gynecology, and plastic surgery dissection while preserving controlled curved blade handling. PS-2662 with 10" (25cm) length is selected when the surgeon needs more shaft clearance around retractors, suction, clamps, and deeper wound corridors. PS-2663 with 11" (28cm) length provides the longest listed reach for abdominal, pelvic, colorectal, and large-animal soft-tissue procedures where the hand must remain outside the main operative cavity. All four variants share the same curved blunt dissecting concept, screw-joint pivot, and ring-handle control, so selection depends on exposure depth, patient habitus, tissue plane, hand clearance, and whether the surgeon is working near the surface or across a deeper corridor. Stocking the full length range supports minor, intermediate, and major procedure trays.

Reusable German Steel Processing and Procurement Documentation

German stainless steel construction supports blade stability, corrosion resistance, and repeatable pivot movement through repeated cleaning and steam sterilization cycles. Satin, dull, and mirror finish options allow procurement teams to match surface preference with glare control, visual inspection, and established operating room tray standards. After use, the blades should be opened and cleared of blood, tissue residue, suture fragments, dressing fibers, graft debris, and lint before enzymatic cleaning. Processing can include manual brushing, ultrasonic decontamination, washer-disinfector exposure, rinsing, drying, screw-joint inspection, cutting-edge review, packaging, and steam autoclave sterilization according to facility protocol. The pivot area requires careful attention because retained debris can alter closure resistance and reduce distal cutting accuracy. CE marking, ISO 13485 documentation, and FDA procurement context support purchasing records for hospitals, clinics, distributors, surgical centers, dental units, veterinary facilities, and teaching programs. Class I classification, reusable construction, carton-box packing, 1-piece MOQ, OEM availability, 1-year warranty, and return and replacement support assist replacement ordering, institutional purchasing, and distributor catalog supply.

SKU PS-OT-01013
Product Name Metzenbaum Dissecting Cutting Scissors
Price $10.01
Size/Gauge Variants PS-2661 overall length 9" (23cm); PS-2662 overall length 10" (25cm); PS-2663 overall length 11" (28cm); PS-2660 overall length 8" (20cm)
Instrument Category Reusable surgical dissecting scissors
Procedure Laparotomy, hysterectomy access, hernia repair, wound revision, superficial adhesiolysis, flap undermining, mucosal edge adjustment, scar revision, biopsy margin refinement, suture cutting, closure-stage soft-tissue management
Material German stainless steel
Finish Satin, dull, or mirror finish
Sterilization Reusable instrument suitable for enzymatic cleaning, ultrasonic decontamination, washer-disinfector processing, drying, pivot inspection, packaging, and steam autoclave sterilization
Instrument Classification Class I reusable surgical instrument
Reusable Yes
Certifications CE, ISO 13485, FDA
Warranty 1 year
MOQ 1 piece
OEM / Custom Orders Available for distributor supply, institutional branding, bulk purchasing, and customized packing programs
After-Sale Service Return and replacement support for eligible orders

How are Metzenbaum Dissecting Cutting Scissors different from Mayo scissors?
Mayo scissors are the closest alternative because they are also used for operating room cutting. Metzenbaum Dissecting Cutting Scissors have a more slender blade profile for fine soft-tissue dissection, flap undermining, and controlled trimming. Mayo patterns are typically selected for denser fascia, sutures, graft material, and stronger general cutting. The Metzenbaum pattern reduces tissue engagement during each closure, which helps when the surgeon works along delicate planes. Both instruments use ring handles and a screw-joint pivot. The clinically relevant difference is blade width, tissue density, and whether the task requires fine dissection or stronger cutting force.

How should the 20cm, 23cm, 25cm, and 28cm variants be selected?
The 20cm PS-2660 variant is selected for compact fields, minor procedure trays, oral soft tissue, superficial wound revision, and close hand control. The 23cm PS-2661 variant suits routine general surgery, gynecology, plastic surgery, and soft-tissue trimming where moderate reach is required. The 25cm PS-2662 variant provides additional clearance around retractors, suction, clamps, and deeper wound corridors. The 28cm PS-2663 variant is selected for abdominal, pelvic, colorectal, and veterinary fields where the handle must remain outside the operative cavity. Metzenbaum Dissecting Cutting Scissors should be matched to exposure depth, tissue plane, patient habitus, and required hand clearance. Stocking all four sizes supports minor, intermediate, and major surgical tray configurations.

What do CE, ISO 13485, and FDA details mean for procurement?
CE documentation supports international conformity records for reusable surgical instrument purchasing. ISO 13485 indicates manufacturing under a medical device management system covering production control, inspection, and traceability. FDA procurement context supports U.S. purchasing files for Class I reusable surgical scissors. Metzenbaum Dissecting Cutting Scissors can be entered into hospital, clinic, dental, veterinary, distributor, and operating room catalogs with documented material, finish, model selections, warranty, MOQ, OEM availability, and after-sale service. These records help purchasing officers, receiving teams, and sterile processing departments align the item with internal approval requirements. The certification profile supports tender files, replacement stock, and standardized surgical tray programs.

How does the screw-joint pivot control cutting during dissection?
The screw-joint pivot is the main control feature because it transfers ring-handle pressure into blade closure. The surgeon places the thumb and ring finger in the handles while using the index finger along the shank to guide the curved blades. As the handles close, the cutting edges meet at the selected mucosal edge, flap margin, fascia strand, suture, scar tissue, or soft-tissue plane. The pivot keeps the blades aligned without a ratchet, spring, or locking catch. Metzenbaum Dissecting Cutting Scissors rely on fingertip pressure, tissue stabilization, blade orientation, and direct visualization rather than mechanical locking. Cleaning around the pivot is important because dried blood, tissue residue, suture fragments, or lint can alter resistance and reduce smooth closure.

Are these scissors suitable for reusable sterile processing and distributor stock?
Yes, Metzenbaum Dissecting Cutting Scissors are reusable German stainless steel instruments suitable for hospital, clinic, dental, veterinary, distributor, surgical center, and operating room supply workflows. After use, the blades and screw joint should be opened so blood, tissue residue, suture fragments, lint, dressing fibers, and graft debris can be removed before sterilization. Processing can include enzymatic cleaning, ultrasonic decontamination, washer-disinfector exposure, drying, pivot inspection, packaging, and steam autoclaving. The 1-piece MOQ supports replacement ordering for small clinics, procedure rooms, specialty trays, and surgical departments. OEM availability supports distributor branding, institutional packing, and bulk purchasing programs. The 1-year warranty and return and replacement service support procurement teams managing recurring dissecting-scissor inventory.

At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.

Eligibility for Returns

To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.

Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.

How to Initiate a Return

To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.

Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States

Return Shipping Costs

No Restocking Fee: We do not charge restocking fees on approved returns.

Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.

Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.

Return Conditions

Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.

Refund Process

Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.

Please note that your bank or credit card provider may require additional time to post the refund to your account.

Damaged, Defective, or Incorrect Items

Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.

Exceptions and Non-Returnable Items

Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.

Exchanges

For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.

Worldwide Shipping

Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.

European Union Customers

For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.

Contact Us

For return, refund, or exchange inquiries, please contact us:

Phone: +1 315 526 9968
Email: info@peaksurgicals.com

Related products