Proximal Humerus Locking Plate Flat, SKU Proximal Humerus Locking Plate Flat 4 to14 Holes, is an orthopedic implant plate manufactured in stainless steel and titanium options for proximal humerus fracture fixation and shoulder reconstruction procedures. The listed flat head configurations include 4 holes, 5 holes, 6 holes, 7 holes, 8 holes, 9 holes, 10 holes, 11 holes, 12 holes, 13 holes, and 14 holes, allowing selection across compact, routine, and extended proximal humeral constructs. The visible implant design includes a flat proximal head, contoured shaft, clustered screw holes, elongated combination openings, countersunk seating zones, and a smooth machined surface for controlled intraoperative handling. It is used during surgical neck fracture stabilization, greater tuberosity fixation, metaphyseal comminution support, proximal humeral osteotomy stabilization, nonunion reconstruction, and selected veterinary shoulder fracture repair. Orthopedic trauma surgeons, shoulder reconstruction specialists, sports trauma teams, hospitals, clinics, distributors, and veterinary orthopedic services can use this implant within CE, ISO 13485, and FDA-compliant procurement workflows.
The flat head configuration is designed for proximal humeral fixation where the surgeon needs broad clustered screw placement without a narrow or hook-based proximal profile. The proximal hole group supports multiple screw trajectories into the humeral head, greater tuberosity region, surgical neck, and metaphyseal segment, helping distribute fixation across cancellous bone and short fragments. The contoured shaft extends distally along the lateral humeral cortex and provides a stable transition from the head cluster to the diaphyseal support zone. Elongated combination openings along the shaft allow controlled placement and compression or locking sequence planning before final screw insertion. Countersunk hole geometry helps screw heads seat within the implant surface after tightening, reducing prominence beneath the deltoid and adjacent soft-tissue envelope. The flat head is selected when the plate footprint must support multiple proximal fixation points while maintaining a controlled implant profile. This geometry supports angular stability, fragment capture, and shaft alignment during shoulder fracture reconstruction.
In operative workflow, Proximal Humerus Locking Plate Flat is introduced after deltopectoral or deltoid-splitting exposure, fracture assessment, reduction, tuberosity control, and provisional fixation have established the intended construct. During surgical neck fracture fixation, the shaft is aligned along the lateral humeral cortex while the proximal cluster is positioned to capture the humeral head segment. In three-part fracture patterns, proximal screws support the head and tuberosity fragments while shaft fixation maintains alignment across the metaphyseal transition. For greater tuberosity involvement, the implant works with reduction sutures, clamps, or temporary wires before final screw placement. In osteotomy or nonunion reconstruction, the plate maintains the planned relationship between proximal and shaft segments after bone preparation. Veterinary orthopedic teams can apply the same fixation principles when implant length, material, and screw system match the planned repair. Final assessment includes fluoroscopic screw length review, head penetration check, shoulder motion clearance, irrigation, and layered closure.
The 4 and 5 hole plates are selected for compact proximal humerus fractures where the shaft segment allows shorter fixation and the surgical exposure favors a smaller construct. The 6 and 7 hole options support routine proximal humeral fracture fixation with additional diaphyseal purchase for surgical neck and metaphyseal patterns. The 8 and 9 hole configurations provide broader load distribution when comminution extends distally or when tuberosity fixation requires a longer shaft support zone. The 10 and 11 hole plates are selected when the fracture line or osteotomy requires extended fixation beyond the proximal metaphysis. The 12, 13, and 14 hole options support long bridging constructs, segmental extension, revision fixation, nonunion reconstruction, and selected veterinary orthopedic repairs involving larger humeral anatomy. Hole-count selection is guided by fracture morphology, bone quality, proximal fragment size, tuberosity involvement, shaft extension, and the screw inventory available in the operating room implant system.
Stainless steel provides rigid fixation behavior and familiar handling for orthopedic trauma inventories, while titanium offers an alternate implant material for facilities managing mixed shoulder fixation systems. The smooth machined finish supports screw seating, visual inspection, and controlled handling during sterile tray preparation. Countersunk openings and elongated shaft holes require inspection before use so the selected screws seat correctly and the implant surface remains free of handling damage. The plate is managed through validated hospital implant handling, packaging, and sterilization workflows before implantation according to facility protocol. After implantation, removal, sterile-field contamination, or loss of sterile integrity, the implant is not returned to reusable instrument circulation. CE marking, ISO 13485 manufacturing controls, and FDA procurement context support purchasing files for hospitals, clinics, distributors, and orthopedic supply departments. The $17.60 price, one-piece MOQ, OEM availability, one-year warranty framework, and return or replacement support help procurement teams manage shoulder fixation inventory and distributor catalog requirements.
| SKU | Proximal Humerus Locking Plate Flat 4 to14 Holes |
|---|---|
| Product Name | Proximal Humerus Locking Plate Flat |
| Price | $17.60 |
| Size/Gauge Variants | 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, and 14 hole flat head configurations |
| Instrument Category | Orthopedic proximal humerus locking implant plate |
| Procedure | Proximal humerus fracture fixation, surgical neck fracture stabilization, greater tuberosity fixation, metaphyseal comminution support, proximal humeral osteotomy stabilization, nonunion reconstruction, veterinary shoulder fracture repair |
| Material | Stainless steel and titanium |
| Finish | Smooth machined implant finish |
| Sterilization | Managed through validated hospital implant sterilization workflow before implantation |
| Instrument Classification | Orthopedic implant plate |
| Reusable | No; single-use implant after sterile implantation |
| Certifications | CE, ISO 13485, FDA |
| Warranty | 1 year |
| MOQ | 1 piece |
| OEM / Custom Orders | OEM available for procurement and distributor requirements |
| After-Sale Service | Return and replacement support |
How does Proximal Humerus Locking Plate Flat differ from Proximal Humerus Locking Plate Narrow?
Proximal Humerus Locking Plate Flat uses a broader flat head configuration for clustered proximal humeral fixation. Proximal Humerus Locking Plate Narrow has a reduced proximal footprint for cases where a smaller lateral implant profile is preferred. The flat version is selected when the surgeon wants broader proximal screw distribution across the humeral head and metaphyseal region. The narrow version is selected when soft-tissue profile, bony anatomy, or surgical approach favors a slimmer head. Proximal Humerus Locking Plate Flat still provides multiple shaft hole options for extended construct planning. The clinically relevant difference is proximal head footprint, screw distribution strategy, and implant profile beneath the shoulder soft-tissue envelope.
Which hole count should be selected for proximal humerus fixation?
Proximal Humerus Locking Plate Flat is available across 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, and 14 hole flat head configurations. Short 4 and 5 hole plates are selected for compact fractures with limited shaft extension. The 6 and 7 hole options support routine surgical neck and metaphyseal fixation. The 8, 9, 10, and 11 hole plates provide additional diaphyseal purchase when fracture extension or bone quality requires broader support. The 12, 13, and 14 hole configurations are selected for long bridging constructs, nonunion reconstruction, revision fixation, and selected veterinary orthopedic repairs. Selection depends on fracture morphology, humeral shaft extension, tuberosity involvement, implant length requirement, and operating room screw system planning.
How do CE, ISO 13485, and FDA details support procurement?
Proximal Humerus Locking Plate Flat is supplied with CE, ISO 13485, and FDA procurement context for orthopedic implant purchasing. CE marking supports conformity documentation for healthcare markets requiring European medical device references. ISO 13485 indicates manufacturing under a medical device quality management system with controlled production and traceability. FDA procurement context supports hospitals, clinics, and distributors serving United States orthopedic supply channels. These details assist tender submissions, vendor onboarding, operating room inventory approval, and distributor catalog documentation. The $17.60 price, one-piece MOQ, OEM availability, and one-year warranty framework support replacement inventory and shoulder fixation tray planning.
How are the locking holes and elongated shaft openings used intraoperatively?
The elongated shaft openings can be used early in placement to help position the plate after fracture reduction and provisional fixation. The surgeon can refine plate height, rotation, and shaft alignment before final screw insertion. Proximal locking holes accept compatible screws that engage the implant and create angular stability across the humeral head and metaphyseal segment. Shaft screws then secure the construct along the lateral humeral cortex according to the selected hole count. Proximal Humerus Locking Plate Flat is applied under direct visualization and fluoroscopic confirmation before final tightening. Final assessment includes screw length, trajectory, head penetration review, tuberosity reduction, shoulder motion clearance, and implant seating.
What should hospitals and distributors consider before ordering this implant?
Hospitals should select Proximal Humerus Locking Plate Flat according to hole count, material preference, screw system, proximal humerus fracture workload, and shoulder reconstruction inventory needs. Stainless steel and titanium options allow procurement teams to align ordering with existing orthopedic implant protocols. Unused plates are managed through validated implant handling, packaging, and sterilization workflows before surgery. After implantation or sterile-field contamination, the plate is treated as a single-use implant and is not returned to reusable tray circulation. Distributors can stock available flat head configurations to support trauma, shoulder reconstruction, veterinary, and teaching hospital demand. The one-piece MOQ, carton-box packing, OEM availability, warranty framework, and return or replacement service support practical inventory planning.
Order Processing: We strive to serve you promptly! Orders placed before the cut-off time of 5:00 PM (GMT -05:00) (Eastern Standard Time) will be processed the same business day. Orders placed after this time will be processed the next business day.
Handling Time: Our standard handling time is 1-2 business days (Monday through Friday). This includes order verification, quality checks, packaging, and dispatch. Please note that orders placed on weekends or holidays will be processed on the following business day.
Transit Time: Once dispatched, the estimated transit time is 4-5 business days (Monday through Friday). However, transit times may vary depending on your location and any unforeseen circumstances.
Shipping Fee: Enjoy free worldwide shipping on all orders over $250! At Peak Surgical Instruments, we cover all import charges for your convenience.
Customers will receive a tracking ID as soon as their order is dispatched via FedEx or DHL.
We proudly offer worldwide shipping, ensuring that our premium surgical instruments are accessible to healthcare professionals across the globe. No matter where you are, you can count on us to deliver quality tools right to your doorstep!
To provide you with confidence in your purchase, we offer a 1-year warranty as well as a 30-day money-back guarantee on all non-personalized orders.
We understand that delays can be frustrating. Transit times are estimates based on recent orders and may change. If your package is delayed, we will do everything possible to expedite delivery. In case of significant delays or missing packages, we will reship your order at no extra cost to you.
At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.
To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.
Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.
To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.
Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States
No Restocking Fee: We do not charge restocking fees on approved returns.
Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.
Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.
Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.
Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.
Please note that your bank or credit card provider may require additional time to post the refund to your account.
Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.
Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.
For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.
Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.
For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.
For return, refund, or exchange inquiries, please contact us:
Phone: +1 315 526 9968
Email: info@peaksurgicals.com