Harrison Butler’s Lachrymal Cannula 3.8cm (1.5”) – Specialized Tear Duct Irrigation The precision standard for nasolacrimal patency. The Harrison Butler’s Lachrymal Cannula is a dedicated ophthalmic instrument engineered for the...
In stock
Price:
$27.50
  • Secure Checkout

    Secured Checkout Guaranteed.

  • 30 Day's Money Back

    30 Day's Money Back Guaranteed.

  • Free Shipping On 99 $

    Free Shipping on Orders Above 99 $.

Harrison Butler’s Lachrymal Cannula 3.8cm (1.5”) Ophthalmic Instrument
Regular price $27.50
Regular price Sale price $27.50 (-0%)
Size: 3.8cm (1.5``)
Harrison Butlers Lachrymal Cannula
Harrison Butler’s Lachrymal Cannula 3.8cm (1.5”) Ophthalmic Instrument
$27.50

Harrison Butler’s Lachrymal Cannula 3.8cm (1.5”) – Specialized Tear Duct Irrigation

The precision standard for nasolacrimal patency. The Harrison Butler’s Lachrymal Cannula is a dedicated ophthalmic instrument engineered for the clinical irrigation and diagnostic probing of the tear drainage system. Featuring a refined 3.8cm (1.5”) profile and a characteristic curved tip, this cannula provides the mechanical necessity for accessing the lacrimal puncta and navigating the canaliculi. It is a foundational tool for ophthalmologists and clinical specialists managing chronic tearing, ductal blockages, and inflammatory conditions of the lacrimal sac.

[Add to Cart – Professional Ophthalmic Grade]

Key Features for Precision Lacrimal Work

  • Anatomically Tapered Curved Tip: The distal end is meticulously curved to mirror the natural anatomy of the lacrimal canal, allowing for low-resistance insertion and smooth navigation through the proximal drainage system.
  • Atraumatic High-Polish Finish: The entire shaft and tip are finished to a mirror-smooth surface, ensuring that the cannula glides over delicate mucosal linings without causing abrasions or creating "false passages."
  • Optimal 3.8cm (1.5”) Length: This compact reach is specifically balanced to provide the practitioner with high tactile feedback, making it easier to "feel" strictures, stones, or complete obstructions within the duct.
  • Universal Luer-Lock Hub: Equipped with a standard hub that secures easily to medical syringes, facilitating the controlled delivery of saline, antibiotics, or diagnostic dyes.
  • Surgical-Grade Stainless Steel: Forged from premium medical steel for superior tensile strength and corrosion resistance, ensuring the fine tip maintains its precise curvature over time.
  • Lightweight, Balanced Design: Engineered for a delicate touch, allowing for the steady hand movements required in microsurgical and diagnostic ophthalmic environments.

Product Overview: Clinical Excellence in Duct Management

The Harrison Butler’s Lachrymal Cannula is an essential instrument for diagnosing and treating disorders of the lacrimal apparatus. Its design focuses on the "Syringing and Probing" (S&P) technique, where fluid is introduced into the punctum to verify the patency of the nasolacrimal duct. By providing a secure connection to a syringe and a smooth distal tip, it allows the clinician to perform these maneuvers with high accuracy and minimal patient distress.

Built for the rigorous sterilization requirements of modern ophthalmology, this cannula is fully autoclavable and designed for a long clinical lifespan. Its reliability makes it a staple in both outpatient clinics and specialized surgical suites. Furthermore, its versatile 1.5-inch length makes it highly effective in veterinary ophthalmology for managing tear duct issues in small animals, where precision is equally paramount.

Specifications & Clinical Applications

Feature Details

Material Premium Surgical Stainless Steel

Total Length 3.8cm (1.5 Inches)

Tip Profile Fine, Blunt Curved Tip

Connection Type Standard Luer Hub

Maintenance Fully Autoclavable / Reusable

Primary Use Cases:

  • Lacrimal System Irrigation: Flushing debris or purulent material from the tear ducts.
  • Diagnostic Probing: Assessing the level of obstruction in patients with epiphora.
  • Dacryocystitis Management: Delivering localized medications or flushing the lacrimal sac.
  • Veterinary Ophthalmology: Probing and syringing tear ducts in domestic pets.
  • Post-Operative Assessment: Confirming ductal patency following nasolacrimal surgery.

Why Professionals Choose Harrison Butler’s Cannula?

  • Targeted Anatomical Design: The Harrison Butler pattern is specifically recognized for its ease of use in adult canalicular navigation.
  • Maximized Safety: The blunt, polished tip is designed to be inherently atraumatic to sensitive ocular tissues.
  • Superior Durability: High-quality steel construction prevents the lumen from collapsing or the tip from dulling.
  • Workflow Integration: Fits seamlessly with standard clinical disposables for immediate procedural use.

Frequently Asked Questions (FAQ)

Q: Is the tip of this cannula sharp or blunt?

A: The tip is strictly blunt. It is an irrigation and probing tool designed to follow natural anatomical passages without piercing or cutting the tissue.

Q: How do I prevent blockages in the cannula lumen?

A: Immediately after the procedure, flush the cannula with distilled water or an enzymatic solution using a syringe. This prevents proteins or saline crystals from drying inside the fine tube.

Q: What is the difference between this and a standard Lang’s cannula?

A: While both serve similar purposes, the Harrison Butler pattern may feature slight variations in the degree of tip curvature or shaft taper, depending on the specific manufacturing pattern. Both are standard choices for lacrimal work.

Q: Can this cannula be used with 10cc syringes?

A: Yes, the hub is compatible with any standard Luer-slip or Luer-lock syringe (1cc to 20cc), though 2cc or 5cc syringes are most commonly used for better pressure control.

At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.

Eligibility for Returns

To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.

Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.

How to Initiate a Return

To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.

Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States

Return Shipping Costs

No Restocking Fee: We do not charge restocking fees on approved returns.

Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.

Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.

Return Conditions

Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.

Refund Process

Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.

Please note that your bank or credit card provider may require additional time to post the refund to your account.

Damaged, Defective, or Incorrect Items

Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.

Exceptions and Non-Returnable Items

Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.

Exchanges

For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.

Worldwide Shipping

Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.

European Union Customers

For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.

Contact Us

For return, refund, or exchange inquiries, please contact us:

Phone: +1 315 526 9968
Email: info@peaksurgicals.com

Related products

Recently viewed products