Skip to content
Couldn't load pickup availability
Secured Checkout Guaranteed.
30 Day's Money Back Guaranteed.
Free Shipping on Orders Above 99 $.

Jako Microlaryngeal Grasping Forceps, SKU PS-OT-0791, is a reusable ENT microlaryngeal forceps made from German stainless steel for precise tissue handling, lesion grasping, and specimen control during endolaryngeal procedures. The model number is PS-5302, with right angled 5mm, straight 3.5mm, and left angled 5mm jaw variants. Its long slender shaft, ring handles, pivoted control joint, and fine distal grasping jaws allow controlled access through a laryngoscope while keeping the surgeon’s hand outside the oral cavity and optical field. It is used during microlaryngoscopy, direct laryngoscopy, vocal fold lesion handling, laryngeal biopsy support, polyp tissue retrieval, supraglottic tissue control, and upper airway examination.
The instrument works through ring handles connected to a pivoted mechanism that transfers finger pressure along the slim shaft to the distal grasping jaws. This configuration supports controlled capture of small tissue fragments, mucosal lesions, polypoid material, biopsy tissue, and delicate endolaryngeal specimens. The narrow shaft helps preserve the laryngoscope corridor for suction, optics, light carriers, microscopes, and assistant instruments. Straight and angled jaw patterns allow the surgeon to match the working tip to target position without rotating the handle into the visual field.
During microlaryngoscopy, Jako Microlaryngeal Grasping Forceps are introduced after exposure is established and the target is identified under direct, endoscopic, or microscopic visualization. The jaws can stabilize vocal fold tissue, retrieve polypoid fragments, support biopsy handling, or grasp small lesions in a restricted airway field. The 3.5mm straight pattern supports fine midline access, while the right and left angled 5mm variants support offset approach to tissue positioned away from the direct shaft axis. The clinical role is precise grasping and retrieval, not suctioning, cautery, powered shaving, or broad dissection.
The straight 3.5mm variant is selected for narrow exposure, fine tissue control, and direct-line microlaryngeal access. The right angled 5mm variant helps approach tissue from a right-directed working angle, while the left angled 5mm variant provides the opposite directional access for contralateral or offset targets. These options allow ENT teams to match jaw angle and bite size to lesion position, laryngoscope exposure, suction placement, microscope angle, and available working space. Keeping all three patterns in a microlaryngeal tray supports consistent handle control with different distal approaches.
German stainless steel construction provides rigidity, corrosion resistance, and dimensional stability for repeated ENT tray use. Satin, dull, and mirror finish options support operating room preferences; lower-reflection surfaces help reduce glare under microscope, endoscope, or headlight illumination, while polished surfaces support inspection after cleaning. Reusable construction fits central sterile workflows involving point-of-use soil removal, manual cleaning, decontamination, jaw function inspection, packaging, and steam autoclave sterilization. CE marking supports European procurement documentation, ISO 13485 alignment reflects medical device manufacturing controls, and FDA-compliant purchasing language assists hospitals, clinics, and distributors serving regulated healthcare markets.
| SKU | PS-OT-0791 |
|---|---|
| Product Name | Jako Microlaryngeal Grasping Forceps |
| Price | $49.50 |
| Model Number | PS-5302 |
| Size/Gauge Variants | Right angled 5mm; straight 3.5mm; left angled 5mm |
| Instrument Category | ENT microlaryngeal grasping forceps |
| Procedure | Microlaryngoscopy, direct laryngoscopy, vocal fold lesion handling, laryngeal biopsy support, polyp tissue retrieval, supraglottic tissue control, upper airway examination |
| Material | German stainless steel |
| Finish | Satin, dull, and mirror finish options |
| Sterilization | Reusable instrument for validated cleaning, decontamination, inspection, and steam autoclave processing |
| Instrument Classification | Class I manual surgical instrument |
| Reusable | Yes |
| Certifications | CE, ISO 13485, FDA |
| Warranty | 1 year |
| MOQ | 1 piece |
| OEM / Custom Orders | Available for eligible procurement and distributor requirements |
| After-Sale Service | Return and replacement support |
How is this different from Jackson Laryngeal Grasping Forceps?
Jako Microlaryngeal Grasping Forceps are selected for fine microlaryngeal tissue control with 3.5mm and 5mm jaw options. Jackson Laryngeal Grasping Forceps are commonly selected for broader laryngeal and upper airway retrieval. The Jako pattern gives ENT surgeons more delicate distal control for vocal fold lesion handling, small biopsy support, and endolaryngeal specimen capture through a restricted laryngoscope corridor.
Which variant should be selected?
The straight 3.5mm pattern is selected for fine midline access and smaller tissue targets. The right angled 5mm and left angled 5mm patterns are selected when the lesion or tissue fragment lies away from the direct shaft axis. Selection depends on target position, laryngoscope exposure, microscope angle, suction placement, and the working room available beside other microlaryngeal instruments.
What does CE, ISO 13485, and FDA context support in procurement?
Jako Microlaryngeal Grasping Forceps are supplied with CE, ISO 13485, and FDA procurement context for regulated surgical instrument purchasing. CE marking supports European medical device supply channels. ISO 13485 alignment relates to manufacturing under a medical device quality management system. FDA-compliant purchasing language assists hospitals, clinics, and distributors serving United States healthcare markets. The product is listed as a Class I manual surgical instrument with MOQ 1 piece and 1-year warranty support.
How does the pivot mechanism support microlaryngeal control?
The ring handles close around a pivot that transfers finger pressure through the slender shaft to the distal jaws. As the surgeon compresses the handles, the working tip approximates around the selected tissue, lesion, biopsy fragment, or polypoid material. The pivot gives tactile feedback, allowing controlled capture and release during microlaryngoscopy without a ratchet lock.
How should ENT teams manage sterilization and stocking?
Jako Microlaryngeal Grasping Forceps should be cleaned after use with attention to the distal jaws, hinge region, shaft, pivot, and ring handles. The jaw mechanism should be opened and closed during cleaning so mucus, blood, tissue, and biological material are removed from moving surfaces. After decontamination and inspection, the instrument can be packaged for steam autoclave sterilization under the facility’s validated protocol. ENT departments can stock the straight, right angled, and left angled variants in microlaryngoscopy, biopsy, vocal fold lesion, and airway procedure trays.
At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.
To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.
Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.
To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.
Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States
No Restocking Fee: We do not charge restocking fees on approved returns.
Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.
Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.
Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.
Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.
Please note that your bank or credit card provider may require additional time to post the refund to your account.
Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.
Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.
For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.
Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.
For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.
For return, refund, or exchange inquiries, please contact us:
Phone: +1 315 526 9968
Email: info@peaksurgicals.com