Skip to product information

House Cup Forceps for 35° and 90° Otologic Tissue Retrieval

SKU: PS-OT-0729
House Cup Forceps, SKU PS-OT-0729, is a reusable ENT cup forceps made from German stainless steel for controlled tissue capture, canal debris retrieval, and small specimen handling in otologic procedures....
In stock
Price:
$25.85
  • Secure Checkout

    Secured Checkout Guaranteed.

  • 30 Day's Money Back

    30 Day's Money Back Guaranteed.

  • Free Shipping On 99 $

    Free Shipping on Orders Above 99 $.

House Cup Forceps for 35° and 90° Otologic Tissue Retrieval
Regular price $25.85
Regular price Sale price $25.85 (-0%)
Pattern: Angled upward 90°
House Cup Forceps
House Cup Forceps for 35° and 90° Otologic Tissue Retrieval
$25.85

House Cup Forceps, SKU PS-OT-0729, is a reusable ENT cup forceps made from German stainless steel for controlled tissue capture, canal debris retrieval, and small specimen handling in otologic procedures. The model number is PS-5218A, with Angled upward 90° and Angled upward 35° pattern variants for different approach angles inside the external auditory canal and middle ear access route. The long slender shaft allows entry through an ear speculum while the ring handles, pivoted joint, and distal cup jaws provide controlled grasping at depth under microscopic or endoscopic visualization. It is used during otomicroscopy, tympanoplasty preparation, myringoplasty support, external auditory canal biopsy, aural polyp removal, granulation tissue retrieval, postoperative ear canal cleaning, mastoid cavity care, and middle ear revision work. Otologists, neurotologists, ENT surgeons, outpatient otology clinics, hospital operating rooms, ambulatory surgery centers, and medical distributors use this instrument when angled cup access is required for small otologic tissue and debris removal.

Angled Cup Jaw Mechanism and Ring Handle Control

The instrument works through ring handles connected to a pivoted joint that transfers finger pressure along the shaft to the distal cup jaws. The long shaft keeps the surgeon’s hand outside the auricle, microscope field, and speculum corridor while the working end advances into a narrow otologic pathway. The cup-shaped distal tips enclose small tissue fragments, granulation material, canal debris, or biopsy specimens instead of holding them between flat grasping blades. This design helps capture friable material during withdrawal from the canal or middle ear approach. The angled upward 35° pattern redirects the bite toward oblique canal wall targets and shallow offset recesses. The angled upward 90° pattern produces a more perpendicular working direction for tissue positioned superior to the shaft line or behind a canal contour. The pivot gives tactile feedback during closure, allowing gradual compression and controlled release after retrieval. This mechanism supports deliberate small-fragment handling without using a cutting punch or broad dressing forceps.

Otologic Tissue Retrieval and Procedure Workflow

During otomicroscopy, House Cup Forceps are introduced after the external auditory canal is exposed through a speculum and the target is identified under magnification. In tympanoplasty preparation, the cup jaws can retrieve small soft tissue fragments, remove obstructing debris, or assist with controlled specimen handling while preserving room for suction, Rosen needles, fine hooks, and graft instruments. In myringoplasty support, the angled tip helps access tissue or packing material near the tympanic membrane margin without enlarging the working corridor. For external auditory canal biopsy, the distal cups capture a defined fragment from a visible lesion, granulation site, or postoperative cavity surface for laboratory transfer. During mastoid cavity care or revision otologic work, the 35° and 90° patterns help reach tissue on offset planes that a straight grasping forceps cannot approach cleanly. The instrument’s role is controlled cup retrieval and small specimen handling, not prosthesis crimping, bone removal, suctioning, or broad canal packing.

35° and 90° Angled Pattern Selection

The Angled upward 35° House Cup Forceps pattern is selected when the target lies on an oblique canal wall, shallow superior recess, mastoid cavity contour, or middle ear access plane that requires a redirected bite without a steep working angle. This option supports controlled retrieval when the surgeon needs the shaft to remain aligned with the speculum corridor while the jaw reaches slightly above the shaft axis. The Angled upward 90° pattern is selected when tissue or debris sits superior to the instrument path and requires a perpendicular cup approach. It is useful for deeper recess work, upper canal wall fragments, selected biopsy sites, and small tissue capture where a lower angle would slide past the target. Both variants share the PS-5218A model reference, long shaft, ring handles, pivot control, and cup jaw working end. Selection depends on canal diameter, target position, microscope angle, suction placement, patient head position, and the depth of the operative field.

Reusable Steel Processing and Procurement Documentation

German stainless steel construction provides rigidity, corrosion resistance, and dimensional stability for repeated otologic tray use. Satin, dull, and mirror finish options support different operating room preferences; lower-reflection surfaces reduce glare under microscope or endoscope illumination, while mirror-polished surfaces allow rapid inspection after cleaning. Reusable construction fits central sterile workflows involving point-of-use soil removal, manual cleaning, decontamination, jaw function inspection, packaging, and steam autoclave sterilization. Cleaning attention should focus on the cup recesses, distal hinge, shaft channel, pivot junction, and handle rings because wax residue, tissue, and dressing fibers can restrict smooth closure. CE marking supports European procurement documentation, ISO 13485 alignment reflects medical device manufacturing controls, and FDA-compliant purchasing language assists hospitals, clinics, and distributors serving regulated healthcare markets. Class I classification fits a non-powered reusable manual forceps used for otologic grasping and retrieval. MOQ 1 piece, OEM availability, 1-year warranty, and return or replacement support provide clear commercial terms for ENT departments and distributor stocking.

SKU PS-OT-0729
Product Name House Cup Forceps
Price $25.85
Size/Gauge Variants Angled upward 90°; Angled upward 35°
Instrument Category ENT otologic cup forceps
Procedure Otomicroscopy, tympanoplasty preparation, myringoplasty support, external auditory canal biopsy, aural polyp removal, granulation tissue retrieval, postoperative ear canal cleaning, mastoid cavity care
Material German stainless steel
Finish Satin, dull, and mirror finish options
Sterilization Reusable instrument for validated cleaning, decontamination, inspection, and steam autoclave processing
Instrument Classification Class I manual surgical instrument
Reusable Yes
Certifications CE, ISO 13485, FDA
Warranty 1 year
MOQ 1 piece
OEM / Custom Orders Available for eligible procurement and distributor requirements
After-Sale Service Return and replacement support

How is this different from House Alligator Grasping Forceps?
House Cup Forceps use cup-shaped distal jaws for enclosing small tissue fragments, biopsy material, granulation tissue, or canal debris. House Alligator Grasping Forceps use narrow alligator jaws for holding cotton, packing, dressing ends, wax fragments, and foreign bodies. The cup pattern is selected when the surgeon needs to capture a small specimen or friable material inside the jaw recess. The alligator pattern is selected when the target must be grasped between narrow tips without cup containment. House Cup Forceps also offer 35° and 90° upward patterns for angled otologic access. The main design difference is enclosed cup retrieval versus alligator-style tip grasping.

When should the 35° or 90° pattern be selected?
House Cup Forceps in the 35° angled upward pattern are selected for oblique canal wall work, shallow superior recess access, and mastoid cavity surfaces that need a redirected but moderate bite. This angle keeps the shaft aligned with the speculum corridor while the cup reaches slightly above the instrument axis. The 90° angled upward pattern is selected when tissue or debris sits superior to the shaft line and requires a perpendicular approach. It is useful for deeper offset targets, upper canal wall fragments, and selected biopsy sites. Selection depends on target location, canal diameter, microscope angle, suction position, and the depth of the operative field. Both patterns support controlled otologic tissue retrieval with the same ring-handle mechanics.

What does CE, ISO 13485, and FDA context support in procurement?
House Cup Forceps are supplied with CE, ISO 13485, and FDA procurement context for regulated surgical instrument purchasing. CE marking supports documentation for European medical device supply channels. ISO 13485 alignment relates to manufacturing under a medical device quality management system. FDA-compliant purchasing language assists hospitals, clinics, and distributors serving United States healthcare markets. These references support vendor review, product file documentation, and reusable ENT tray purchasing. The product is listed as a Class I manual surgical instrument with MOQ 1 piece and 1-year warranty support.

How does the pivot mechanism control the cup jaws?
The ring handles close around a pivot that transfers finger pressure through the shaft to the distal cup jaw assembly. As the surgeon compresses the handles, the cups approximate around the selected tissue fragment, debris, or biopsy specimen. The pivot gives tactile feedback, allowing controlled closure without excessive compression of friable material. This is important during otomicroscopy, tympanoplasty preparation, canal biopsy, and postoperative cavity care. House Cup Forceps do not require a ratchet because grasping pressure is maintained by continuous hand control. The angled shaft preserves the microscope field while the distal cups work through the speculum corridor.

How should ENT teams manage sterilization and stocking?
House Cup Forceps should be cleaned after use with attention to the cup recesses, distal hinge, shaft channel, pivot, and ring handles. The jaw mechanism should be opened and closed during cleaning so wax residue, tissue, and biological material are removed from moving surfaces. After decontamination and inspection, the instrument can be packaged for steam autoclave sterilization under the facility’s validated protocol. ENT departments can stock 35° and 90° upward patterns in otology, tympanoplasty, canal biopsy, postoperative ear care, and outpatient procedure trays. Distributors can order MOQ 1 piece for replacement supply or catalog stocking. Return and replacement support plus 1-year warranty terms help procurement teams manage reusable otologic cup forceps inventory.

At Peak Surgicals, customer satisfaction and product quality are important to us. We offer a straightforward 30-day return policy, allowing eligible items to be returned within 30 days of delivery.

Eligibility for Returns

To qualify for a return, the item must be unused, in its original condition, and returned in the original packaging with tags, labels, and proof of purchase included.

Items must not show signs of use, alteration, damage, sterilization, or clinical handling after delivery.

How to Initiate a Return

To start a return, please contact us at info@peaksurgicals.com with your order number, product details, and reason for return.

Approved returns should be sent to:
Peak Surgicals
364 E Main Street
Middletown, DE 19709
Delaware, United States

Return Shipping Costs

No Restocking Fee: We do not charge restocking fees on approved returns.

Free Returns: If the item is incorrect, defective, or damaged during shipping, Peak Surgicals will cover the return shipping cost.

Customer Responsibility: If the customer ordered the wrong item or no longer needs the product, the customer is responsible for the return shipping cost.

Return Conditions

Returned products must be received in new, unused condition with all labels, packaging, and documentation intact. Items that are used, damaged, altered, incomplete, or returned without approval may not be eligible for a refund.

Refund Process

Once your return is received and inspected, we will notify you whether the refund has been approved. Approved refunds will be processed to the original payment method within 10 business days.

Please note that your bank or credit card provider may require additional time to post the refund to your account.

Damaged, Defective, or Incorrect Items

Please inspect your order immediately after delivery. If your item is defective, damaged, or incorrect, contact us at info@peaksurgicals.com as soon as possible with your order number and clear photos of the product and packaging.

Exceptions and Non-Returnable Items

Certain items may not be eligible for return, including customized products, personalized instruments, special-order items, clearance items, sale items, and gift cards.

Exchanges

For exchanges, please return the original item after approval and place a new order for the replacement item. This helps ensure faster processing and accurate product selection.

Worldwide Shipping

Peak Surgicals supplies surgical, dental, orthopedic, gynecology, and veterinary instruments to healthcare professionals, clinics, hospitals, distributors, and procurement buyers worldwide.

European Union Customers

For orders shipped to the European Union, customers may have the right to cancel or return an eligible order within 14 days of receipt, provided the item is unused, in its original condition, and returned with all original packaging and proof of purchase.

Contact Us

For return, refund, or exchange inquiries, please contact us:

Phone: +1 315 526 9968
Email: info@peaksurgicals.com

Related products