Gå vidare till innehåll
Utvald kollektion
PEAK SURGICALS
Lagerhållningsenhet:PS-J-177
Det gick inte att ladda hämtningstillgänglighet

The SofTouch Endoscopic Forehead Arcus Marginalis Periosteal Scissors are specialized surgical scissors designed for periosteal dissection and cutting during endoscopic forehead and brow-lift procedures. Featuring an insulated malleable shaft, straight cutting blades, and an in-line ergonomic handle, this instrument provides a dedicated configuration for selected endoscopic facial surgery techniques.
The instrument features a 6-inch (15 cm) malleable shaft and a specialized working end for dissecting the periosteum at or immediately above the arcus marginalis. It is also designed for cutting periosteal attachments along the superolateral orbital rim.
The SofTouch Endoscopic Periosteal Scissors incorporate a fine straight cutting-blade configuration for working within selected periosteal dissection planes.
The cutting end is intended for surgical division of periosteal tissue and associated attachments during appropriate endoscopic approaches.
The manufacturer identifies the instrument as suitable for right- or left-directed cutting through its specialized handle and working-end arrangement.
Blade positioning, cutting direction, and the extent of tissue division depend on the operative plan, surgical anatomy, and the surgeon's technique.
A defining feature of the SofTouch instrument is its 15 cm insulated malleable shaft. The shaft can be shaped for positioning according to its intended instrument design and applicable manufacturer instructions.
The insulated shaft and fine working end provide a specialized profile for selected endoscopic facial procedures.
The instrument should not be bent beyond the limits established by the manufacturer. The insulation and shaft should be examined before each procedure for visible wear, damage, or deformation.
The presence of shaft insulation does not independently establish compatibility with electrosurgical generators or other powered equipment.
The instrument features an in-line ergonomic handle designed for manipulation using the thumb and index finger.
Its control arrangement allows the surgeon to operate the working blades through small movements of the hand and fingers.
The handle differs from conventional ring-handled surgical scissors, which use two circular finger loops for opening and closing the blades.
The SofTouch design accommodates different hand positions during instrument manipulation and is intended to provide tactile feedback through its specialized handle arrangement.
The illustrated instrument incorporates a connection opening identified as a flush port near the junction between the shaft and handle.
The flush-port assembly is a distinct design feature of this endoscopic instrument. Its use during cleaning and instrument processing should follow the applicable manufacturer instructions.
No specific flushing pressure, cleaning solution, or connection accessory is specified without product-specific documentation.
The SofTouch Arcus Marginalis Periosteal Scissors are designed for dissection of the periosteum at or just above the arcus marginalis during selected endoscopic forehead procedures.
The arcus marginalis is an anatomical structure near the orbital rim where the periosteum is associated with the orbital retaining structures.
During an appropriate endoscopic surgical approach, the surgeon may use specialized scissors to divide selected periosteal attachments as required by the operative plan.
The instrument is also intended for cutting periosteal attachments at the superolateral orbital rim.
The fine working blades and malleable shaft provide an instrument configuration for accessing the relevant dissection area during selected endoscopic approaches.
The technique, direction of cutting, and instrument positioning remain dependent on the patient's anatomy and the surgeon's assessment.
The SofTouch Endoscopic Forehead Scissors are relevant to endoscopic brow-lift and forehead surgery procedures involving planned periosteal release.
They may be used as part of a dedicated endoscopic instrument setup alongside appropriate elevators, dissectors, graspers, retractors, and visualization equipment.
The instrument is intended for professional use by appropriately trained surgical personnel.
This configuration features a straight cutting blade and a 15 cm curved, malleable shaft.
The instrument incorporates an insulated shaft and in-line ergonomic handle, with a working arrangement described by the reference manufacturer as allowing right- or left-directed cutting.
This model should be distinguished from endoscopic corrugator scissors and other forehead instruments with different blade shapes or intended surgical functions.
| Product Name | SofTouch Endoscopic Forehead Arcus Marginalis Periosteal Scissors |
|---|---|
| Instrument Pattern | SofTouch Endoforehead |
| Reference Model | B 65090 |
| Instrument Type | Endoscopic Periosteal Scissors |
| Shaft Length | 6 inches / 15 cm |
| Blade Configuration | Straight |
| Shaft Configuration | Curved, Malleable |
| Shaft Insulation | Insulated |
| Handle Design | In-Line Ergonomic Handle |
| Handle Operation | Thumb and Index Finger Control |
| Cutting Orientation | Right / Left |
| Additional Feature | Flush Port |
| Primary Specialty | Endoscopic Plastic and Facial Surgery |
| Clinical Application | Arcus Marginalis Periosteal Dissection and Cutting |
| Associated Procedures | Endoscopic Forehead and Brow-Lift Surgery |
Before clinical use, inspect the fine cutting blades for visible wear, deformation, or damage. Examine the shaft, insulation, flush-port opening, and handle components for structural integrity.
Verify that the blades open and close appropriately and that the handle mechanism operates according to the applicable manufacturer instructions.
Clean and process the instrument according to its product-specific reprocessing instructions and the healthcare facility's validated surgical instrument-processing procedures.
Pay particular attention to the fine cutting end, insulated shaft, control assembly, and flush-port area during inspection and cleaning.
Do not assume specific sterilization temperatures, exposure times, flushing pressures, or cleaning-agent compatibility without verified product instructions.
During storage and transportation, protect the fine blade tips, shaft insulation, and handle mechanism from mechanical damage.
Peak Surgicals supplies specialized surgical instruments for hospitals, facial plastic surgery practices, endoscopic forehead surgery departments, aesthetic surgical clinics, distributors, and medical procurement professionals.
When selecting this instrument, specify the 15 cm malleable shaft, straight cutting blade, insulated configuration, and in-line ergonomic handle.
The corresponding reference catalog model is B 65090. Confirm the required instrument configuration and inventory reference when ordering.
Explore related Endoscopic Face and Forehead Lift Instruments for additional surgical scissors, dissectors, elevators, retractors, and specialized instruments used in endoscopic facial surgery.
They are designed for periosteal dissection at or above the arcus marginalis and for cutting selected periosteal attachments at the superolateral orbital rim.
The instrument features a 6-inch (15 cm) malleable shaft.
Reference model B 65090 has straight cutting blades with a curved malleable shaft.
Yes. The SofTouch configuration features an insulated malleable shaft.
Yes. The reference manufacturer describes the handle arrangement as allowing right- or left-directed cutting.
They have an in-line ergonomic handle designed for thumb-and-index-finger manipulation, with a flush-port connection assembly.