Gå vidare till produktinformation
1 av 3

PEAK SURGICAL

Lahey gallgångstång för 19,1-23 cm traktion av gallgångar

Lahey gallgångstång för 19,1-23 cm traktion av gallgångar

Lagerhållningsenhet:PS-OT-0871

Ordinarie pris $7.70 USD
Ordinarie pris Försäljningspris $7.70 USD
Rea Slutsåld
Skatter ingår. Frakt beräknas i kassan.
Kvantitet
Secure Checkout Protected payment flow
Quality Inspected Checked before dispatch
Worldwide Supply International buyer support
Shipping, Returns & Payments Clear buyer information before checkout.
Shipping
Free shipping on orders over $99. See shipping details
Returns
Returns and exchanges are handled according to our return policy. See return policy
Payments
American Express Apple Pay Diners Club Discover Google Pay JCB Mastercard
Visa alla uppgifter

Lahey Gall Duct Forceps, SKU PS-OT-0871, are reusable biliary and gall duct forceps manufactured from German stainless steel for controlled grasping, traction, clamping support, and tissue handling during open gallbladder and biliary surgery. The available variants are PS-1356 with angled serrations and 9" (23cm) overall length, and PS-1355 with angled serrations and 7 1/2" (19.1cm) overall length. The image shows curved angled jaws, serrated working surfaces, long shanks, a box-lock joint, finger-ring handles, and a ratchet locking mechanism for maintained closure after placement. General surgeons, hepatobiliary surgeons, gastrointestinal surgeons, pediatric surgeons, veterinary surgeons, and operating room staff use this pattern during open cholecystectomy, common bile duct exploration, cystic duct handling, choledochotomy support, gallbladder traction, Calot’s triangle exposure, biliary stone access, T-tube placement support, ductal tissue stabilization, ligature placement, and closure-stage field control in hospitals, surgical centers, veterinary theaters, teaching laboratories, and reusable biliary procedure trays.

Angled Serrated Jaw Purchase and Ratchet-Controlled Handling

The working action is produced by two opposing angled jaws joined through a box-lock joint that transfers ring-handle compression into aligned distal closure. The curved jaw profile allows the surgeon to approach biliary tissue from an oblique path without forcing the hand into the central operative line. Angled serrations improve purchase on ductal tissue, gallbladder tissue, fibrous bands, and selected soft-tissue structures during traction, exposure, and temporary holding. The jaw curvature supports work around the cystic duct, gallbladder neck, common bile duct region, and adjacent operative instruments. Long shanks keep the handles outside the immediate biliary field while maintaining access for suction, retractors, scissors, dissectors, needle holders, and ligature material. The box lock keeps both arms centered during closure and reduces lateral jaw movement while the working end is seated. Ring handles provide controlled thumb and finger movement during placement and release. The ratchet near the handles locks at staged closure points, maintaining grasp while dissection, ligation, duct inspection, or closure work continues.

Biliary Exposure and Duct Manipulation Workflow

During open cholecystectomy, Lahey Gall Duct Forceps are applied after exposure of the gallbladder, cystic duct region, and operative field has been established. The angled jaws support controlled traction on selected gallbladder or ductal tissue while the surgeon defines Calot’s triangle, identifies ductal orientation, and coordinates dissection around adjacent vessels and connective tissue. In common bile duct exploration, the instrument assists with localized tissue stabilization during choledochotomy exposure, stone access, duct inspection, and T-tube placement support. The serrated working surface helps maintain purchase when ductal or fibrous tissue must remain controlled during ligature placement or suture handling. In veterinary abdominal surgery, the same mechanism supports gallbladder and biliary soft-tissue manipulation where curved access is required. The forceps are positioned only after the target structure is visually identified and seated within the jaw line. The ratchet is engaged after the required closure level is reached, keeping the selected tissue stable while suction, retractors, clamps, scissors, or needle holders remain active in the same field.

PS-1356 and PS-1355 Length Selection

PS-1355 with 7 1/2" (19.1cm) overall length is selected when the surgeon needs compact-to-intermediate reach for open gallbladder exposure, superficial biliary dissection, cystic duct handling, and procedure trays where close hand control is required. This model is useful when the target tissue lies near the wound opening and the operative field already contains retractors, suction tubing, or assistant instruments. PS-1356 with 9" (23cm) overall length is selected when deeper access is required around the gallbladder fossa, common bile duct region, or abdominal wound depth. The longer model keeps the hand outside the operative line while preserving angled jaw control. Both variants use angled serrations, ring handles, a box-lock joint, and ratchet closure, so selection depends on access depth, tissue position, wound width, retractor placement, patient habitus, and required hand clearance. Stocking both lengths supports hepatobiliary trays, general abdominal sets, gastrointestinal surgery packs, pediatric surgical setups, veterinary biliary instruments, and teaching-lab procedure kits.

German Steel Reprocessing and Procurement Documentation

German stainless steel construction supports repeated clinical use by maintaining jaw alignment, serration definition, corrosion resistance, box-lock stability, and ratchet function through cleaning and steam sterilization cycles. Satin, dull, and mirror finish options allow procurement teams to match surface preference with glare control, visual inspection, and established biliary or general surgery tray standards. After use, the jaws should be opened and cleared of blood, bile residue, tissue fragments, fat, suture debris, dressing fibers, and lint before enzymatic cleaning. Processing can include manual brushing, ultrasonic decontamination, washer-disinfector exposure, rinsing, drying, box-lock inspection, ratchet review, serration inspection, packaging, and steam autoclave sterilization according to facility protocol. The angled jaw grooves, joint area, and locking teeth require careful cleaning because retained residue can affect grip, closure, and release. CE marking, ISO 13485 documentation, and FDA procurement context support purchasing records for hospitals, clinics, surgical centers, veterinary facilities, distributors, and teaching programs. Class I classification, reusable construction, carton-box packing, 1-piece MOQ, OEM availability, 1-year warranty, and return and replacement service support institutional replacement ordering.

SKU PS-OT-0871
Product Name Lahey Gallgångstång
Price $7.70
Size/Gauge Variants PS-1356 vinklade serrationer, total längd 23 cm (9 tum); PS-1355 vinklade serrationer, total längd 19,1 cm (7 1/2 tum)
Instrument Category Återanvändbar tång för gallgångar
Procedure Öppen kolecystektomi, exploration av gemensamma gallgången, hantering av cystiska gången, stöd vid koledokotomi, traktion av gallblåsan, exponering av Calots triangel, åtkomst av gallsten, stöd vid T-rörplacering, stabilisering av gångvävnad, ligaturplacering
Material Tyskt rostfritt stål
Finish Satin, matt eller spegelblank finish
Sterilization Återanvändbart instrument lämpligt för manuell rengöring, ultraljudsdekontaminering, rengöring med diskdesinfektor, torkning, kontroll av boxlås och spärr, förpackning och ångautoklavsterilisering
Instrument Classification Klass I återanvändbart kirurgiskt instrument
Reusable Ja
Certifications CE, ISO 13485, FDA
Warranty 1 år
MOQ 1 stycke
OEM / Custom Orders Tillgängligt för distributörsförsörjning, institutionell branding, bulkköp och anpassade förpackningsprogram
After-Sale Service Retur- och utbytesservice för berättigade beställningar

Hur skiljer sig Lahey Gallgångstång från Mixter Gallgångstång?
Mixter Gallgångstång är det närmaste alternativet eftersom båda instrumenten används vid gallblås- och gallgångskirurgi. Mixter-mönster väljs vanligen för passage i rät vinkel runt gångar, kärl och djupa vävnadsplan. Lahey Gallgångstång använder vinklade serrerade käkar för kontrollerat grepp, traktion och vävnadsstabilisering runt gallblåsan och gallgångsfältet. Detta gör Lahey-mönstret användbart när kirurgen behöver bibehållet grepp om utvald vävnad under exponering och ligaturarbete. Båda instrumenten använder ringhandtag, ett boxlås och spärrkontrollerad stängning. Den kliniskt relevanta skillnaden är käkgeometrin, angreppsvinkeln och om steget kräver dissektion i rät vinkel eller serrerad vinklad vävnadshållning.

Hur ska PS-1356 och PS-1355 väljas?
PS-1355 med 19,1 cm (7 1/2") total längd väljs för kompakt till medelstor öppen gallblåseexponering när målet ligger närmare såröppningen. Den stöder hantering av cystiska gången, traktion av gallblåsehalsen och lokaliserad stabilisering av gallvävnad. PS-1356 med 23 cm (9") total längd väljs när djupare åtkomst krävs runt gallblåsefossan, det gemensamma gallgångsområdet eller större bukexponering. Lahey Gallgångstång bör matchas med åtkomstdjup, gångposition, retraktorer, sårbredd, vävnadstäthet och handfrigång. Den kortare modellen ger närmare kontroll nära operationsfältet. Den längre modellen håller handen längre bort från det centrala gallarbetsområdet samtidigt som den bibehåller vinklad käkplacering.

Vad innebär CE, ISO 13485 och FDA för inköp?
CE-dokumentation stöder internationella överensstämmelseregister för inköp av återanvändbara kirurgiska instrument. ISO 13485 indikerar tillverkning under kontroll av medicintekniska produkter som omfattar inspektion, processkonsistens och spårbarhet. FDA:s upphandlingssammanhang stöder amerikanska inköpsfiler för återanvändbara kirurgiska instrument i klass I. Lahey Gallgångstång kan införas i sjukhus-, klinik-, veterinär-, distributörs- och operationsrumskataloger med dokumenterat material, finish, modellvarianter, garanti, MOQ, OEM-tillgänglighet och eftermarknadsservice. Dessa register stöder inköpsteam, mottagningsavdelningar och sterila bearbetningsenheter vid lagergodkännande. Certifieringsprofilen stöder anbudshandlingar, ersättningslager, gallkirurgiska brickor, allmänna buksatser, gastrointestinala operationspaket, pediatriska operationsuppsättningar och institutionella försörjningsprogram.

Hur kontrollerar spärren och boxlåset användningen under operation?
Boxlåset är den centrala gångjärnen som håller båda tångarmarna i linje under öppning och stängning. Spärren är låsfunktionen nära handtagen som håller de vinklade käkarna vid stegvisa kompressionspunkter. Under användning placerar kirurgen de serrerade käkarna på den valda gallblåsan, cystiska gången, gångvävnaden eller fiberstrukturen och stänger sedan handtagen till önskat grepp. Detta gör att Lahey Gallgångstång kan bibehålla kontrollen över gallvävnaden medan ligaturer, saxar, sug, retraktioner eller nålhållare används i samma fält. Frigöring kontrolleras genom att separera spärrtänderna innan käkarna öppnas igen. Rengöring runt boxlåset, de vinklade serrationerna och spärren är viktigt eftersom kvarvarande rester av blod, galla, vävnadsfragment eller ludd kan påverka låsning och frigöring.

Är dessa tänger lämpliga för återanvändbar steril bearbetning och distributörslager?
Ja, Lahey Gallgångstång är återanvändbara instrument av tyskt rostfritt stål som är lämpliga för arbetsflöden på sjukhus, kliniker, veterinärkliniker, distributörer, kirurgiska centra och operationssalar. Efter användning ska de vinklade serrerade käkarna, boxlåset och spärren öppnas och inspekteras så att blod, gallrester, vävnadsfragment, fett, ludd och suturrester kan avlägsnas före sterilisering. Bearbetningen kan inkludera manuell rengöring, ultraljudsdekontaminering, rengöring med diskdesinfektor, torkning, ledinspektion, spärrgranskning, serrationsinspektion, förpackning och ångautoklavering. MOQ på 1 stycke stöder beställning av ersättningsdelar för kliniker, procedurrum, hepatobila brickor, gastrointestinala set och veterinära operationspaket. OEM-tillgänglighet stöder distributörsbranding, institutionell packning och bulkinköpsprogram. Den 1-åriga garantin och retur- och utbytesservicen stöder inköpsteam som hanterar återkommande lager av gallgångstänger.