Ignorer et passer au contenu
Votre panier est vide
Continuer les achatsVous possédez un compte ?
Connectez-vous pour payer plus vite.
Collection en vedette
PEAK SURGICALS
SKU:PS-M-199
Impossible de charger la disponibilité du service de retrait

The Miller Rake Retractor is a stainless steel surgical instrument designed for skin and soft-tissue retraction during facial plastic and reconstructive surgery. Featuring nine sharp prongs arranged in a rake-shaped working end, the instrument provides multiple tissue-engagement points for surgical exposure.
Measuring 5¼ inches (13.5 cm) in overall length, this Miller pattern retractor combines a multi-prong working end, narrow connecting shaft, and elongated flat handle. Its nine-prong design distinguishes it from single skin hooks, double hooks, and retractors with broad solid blades.
The Miller Rake Retractor features nine sharp prongs positioned along a transverse working head. The rake configuration provides multiple points for engaging selected skin or soft tissue during surgical retraction.
The sharp prongs are designed for tissue engagement rather than cutting or dissection. Appropriate placement and traction depend on the surgical technique and the characteristics of the tissue being handled.
Unlike blunt rake retractors, the sharp-prong configuration is intended for applications where the surgeon specifically selects pointed tissue-engaging tips.
The instrument is manufactured from stainless steel. Its construction includes an elongated handle, slender shaft, and specialized rake-shaped working end.
The working head and prongs should be inspected before use for deformation, surface irregularities, or damaged tips. Particular attention should be given to the integrity and alignment of all nine prongs.
The Miller Rake Retractor incorporates a straight, elongated handle with a smooth exterior profile.
The flat handle provides a defined surface for manual gripping and positioning. A narrowed shaft connects the handle to the transverse rake head.
This handle and shaft arrangement allows the operator to position the rake-shaped working end during the selected retraction technique.
The Miller Rake Facial Retractor is associated with facial plastic surgery and reconstructive procedures requiring manual retraction of skin or superficial tissues.
During selected facial surgical approaches, the surgeon or assistant may use a rake retractor to hold tissue away from the operative area and maintain the required exposure.
The nine-prong configuration offers a different tissue-engagement pattern from retractors featuring a single hook or a broad continuous blade.
The suitability of the instrument depends on the operative site, tissue characteristics, intended retraction force, and surgeon preference. Sharp-prong instruments should be positioned and manipulated according to the relevant surgical technique.
The Miller pattern is relevant to plastic surgery departments, reconstructive surgery practices, facial surgery clinics, and hospitals maintaining specialized tissue-retraction instruments.
A conventional single skin hook has one tissue-engaging point. The Miller Rake Retractor features nine sharp prongs arranged across a transverse working head.
This design provides multiple engagement points for selected retraction techniques. The choice between a skin hook, rake retractor, or solid-blade retractor depends on the surgical field and the tissue being handled.
| Product Name | Miller Rake Retractor |
|---|---|
| Instrument Pattern | Miller |
| Catalog Reference | B 61043 |
| Instrument Type | Facial Rake Retractor |
| Material | Stainless Steel |
| Overall Length | 5¼ inches / 13.5 cm |
| Number of Prongs | 9 |
| Prong Type | Sharp |
| Working End | Transverse Rake-Shaped Head |
| Shaft Configuration | Straight, Narrow |
| Handle Design | Long, Flat Handle |
| Primary Specialty | Facial Plastic and Reconstructive Surgery |
| Clinical Application | Skin and Soft-Tissue Retraction |
Before clinical use, inspect all nine sharp prongs for bending, damaged tips, or irregular alignment. Examine the rake head, connecting shaft, and handle for visible wear or structural defects.
Clean and process the instrument according to the applicable manufacturer instructions and the healthcare facility's validated instrument-reprocessing procedures.
Particular attention should be given to the spaces between the prongs during cleaning and inspection.
Protect the sharp working end during instrument transportation and storage to minimize accidental damage to the prongs and adjacent instruments.
Peak Surgicals supplies surgical instruments for plastic surgery practices, reconstructive surgery departments, hospitals, clinics, distributors, and medical procurement professionals.
When selecting this instrument, specify the Miller Rake Retractor, 13.5 cm overall length, with nine sharp prongs. The corresponding catalog reference is B 61043.
Explore related Rake Retractors for additional instruments used in plastic and reconstructive surgery.
It is used for skin and superficial soft-tissue retraction during selected facial plastic and reconstructive surgical procedures.
The Miller Rake Retractor measures 5¼ inches (13.5 cm) in overall length.
It features nine sharp prongs arranged in a transverse rake-shaped working head.
This configuration has nine sharp prongs.
The instrument is made from stainless steel.
The catalog reference is B 61043, identifying the 13.5 cm Miller Rake with nine sharp prongs.