Ugrás a tartalomhoz
Kiemelt kollekció
PEAK SURGICALS
Termékváltozat:PS-M-197
Nem sikerült betölteni az átvehetőségi adatokat

The Aufricht Nasal Retractor with Suction is a specialized stainless steel surgical instrument designed for nasal soft-tissue retraction and suction or smoke evacuation during rhinoplasty and nasal reconstructive procedures. Featuring a concave tapered blade and integrated suction channel, this instrument combines tissue retraction with access to suction at the operative site.
Measuring 7 inches (18 cm) in overall length, the Aufricht Nasal Retractor features a 45 mm tapered blade. Its curved working end, elongated body, and rear suction connector distinguish it from conventional Aufricht retractors without integrated suction.
The instrument incorporates a concave working blade designed for retracting nasal soft tissues during selected rhinoplasty techniques. Its curved and tapered profile provides a defined retraction surface for surgical exposure.
The 45 mm blade dimension identifies the working blade length. The instrument is designed for tissue retraction rather than cutting or cartilage removal.
Blade positioning and applied retraction force must be determined by the surgeon according to nasal anatomy, tissue characteristics, and the operative approach.
The Aufricht Retractor with Suction features an integrated suction passage that allows connection to an appropriate external suction system.
This arrangement supports suction or smoke evacuation from the operative area while the retractor maintains selected tissue exposure.
The suction channel is integrated into the instrument design, helping combine retraction and evacuation functions within one surgical instrument.
The instrument does not generate suction independently. Effective operation requires a suitable external suction source and compatible connection accessories.
A cylindrical suction connector is positioned at the rear of the instrument. This connection provides an interface for the suction system used during the surgical procedure.
Before use, confirm that the suction tubing and external suction equipment are compatible with the instrument connection. No specific suction tubing diameter or vacuum setting is assigned without product-specific documentation.
The instrument is manufactured from stainless steel and combines a curved retraction blade, elongated body, and integrated suction pathway.
The working end and suction components should be inspected before clinical use for visible damage, obstruction, deformation, or other irregularities.
The Aufricht Nasal Retractor with Suction is associated with rhinoplasty and nasal reconstructive surgery where soft-tissue retraction and surgical-site suction are required.
During selected nasal procedures, the surgeon or assistant may use the curved blade to retract tissues and expose the operative area.
The integrated suction passage provides an additional function for evacuation of fluids or surgical smoke when connected to appropriate equipment.
Combining these functions can be useful in surgical setups where the operating team requires both nasal tissue exposure and suction access near the working blade.
The instrument is relevant to facial plastic surgery practices, rhinoplasty clinics, reconstructive surgery departments, and hospitals maintaining dedicated nasal surgical instrumentation.
The Aufricht Nasal Retractor family includes standard, fiber-optic, and suction configurations with an 18 cm overall length and 45 mm tapered blade.
The standard configuration provides nasal tissue retraction without an integrated light guide or suction channel.
The fiber-optic configuration incorporates a light guide intended for use with compatible external surgical illumination equipment.
The suction configuration features an integrated evacuation channel and rear suction connector. This is the configuration described on this product page.
| Product Name | Aufricht Nasal Retractor with Suction |
|---|---|
| Instrument Pattern | Aufricht |
| Catalog Reference | B 61024 |
| Instrument Type | Nasal Retractor with Suction |
| Material | Stainless Steel |
| Overall Length | 7 inches / 18 cm |
| Blade Dimension | 45 mm Tapered Blade |
| Blade Design | Concave, Curved, Tapered |
| Suction Feature | Integrated Suction Channel |
| Evacuation Function | Suction / Smoke Evacuation |
| Connection | Rear Cylindrical Suction Connector |
| Related Standard Model | B 61027 |
| Related Fiber-Optic Model | B 61028 |
| Primary Specialty | Rhinoplasty / Plastic Surgery |
| Clinical Application | Nasal Soft-Tissue Retraction and Surgical-Site Suction |
Before clinical use, inspect the retractor blade for deformation, irregular edges, surface damage, or excessive wear.
Examine the integrated suction passage and rear connector for visible obstruction or mechanical damage. Check the suction pathway according to the applicable manufacturer instructions before connecting the instrument to external equipment.
Clean and process the instrument according to the manufacturer's product-specific instructions and the healthcare facility's validated reprocessing procedures.
Particular attention should be given to the internal suction pathway, connection fitting, and areas where surgical debris may accumulate.
Do not assume specific sterilization temperatures, processing cycles, suction pressures, or tubing compatibility without verified product documentation.
Peak Surgicals supplies specialized surgical instruments for hospitals, facial plastic surgery practices, rhinoplasty clinics, reconstructive surgery departments, distributors, and medical procurement professionals.
When ordering, specify the Aufricht Nasal Retractor with Suction, 18 cm overall length, and 45 mm tapered blade. The corresponding catalog reference is B 61024.
Confirm the required suction equipment and connection arrangement before purchase.
Browse related Nasal Retractors for additional instruments used in rhinoplasty and nasal reconstructive surgery.
It is used for nasal soft-tissue retraction with suction or smoke evacuation during selected rhinoplasty and nasal surgical procedures.
The retractor measures 7 inches (18 cm) in overall length.
It has a 45 mm concave tapered blade for nasal soft-tissue retraction.
Yes. It features an integrated suction passage and rear connection fitting for use with appropriate external suction equipment.
No. This is the suction configuration, reference B 61024. The fiber-optic version is a separate model, B 61028.
The instrument is manufactured from stainless steel.