Gå til indhold
Udvalgt Kollektion
PEAK SURGICALS
SKU:PS-J-192
Tilgængelighed for afhentning kunne ikke indlæses

The Safety Implant Cutter with Telescopic Handles is a reusable stainless steel veterinary orthopedic instrument designed for cutting compatible fixation pins and implants up to 4 mm in diameter. Featuring a specialized safety cutting head, telescopic handles, and a removable head assembly, it provides a dedicated configuration for orthopedic pin trimming.
The cutter has a maximum cutting capacity of 4.0 mm and is designed to produce a smoother cut end than a conventional cutter. The separated pin fragment is temporarily retained within the cutting head rather than being released freely into the surrounding surgical area.
The telescopic handle arrangement allows the overall instrument length to be reduced from 470 mm to 340 mm for storage and reprocessing preparation.
The primary distinguishing feature of the Safety Implant Cutter is its specialized cutting head, which temporarily retains the separated end of a fixation pin after cutting.
During orthopedic procedures, conventional cutting instruments may release small metal fragments when a pin is shortened. The reference cutter is designed to retain the detached section within its head, reducing the risk of an uncontrolled fragment being projected away from the cutting site.
The retained fragment must be removed and accounted for according to the applicable instrument instructions and surgical facility procedures.
The 4mm Safety Implant Cutter is specified for compatible orthopedic fixation pins with a maximum diameter of 4.0 mm.
The instrument may be used for cutting selected pins associated with external skeletal fixation systems and other orthopedic applications where the material and diameter are compatible.
The maximum cutting capacity must not be exceeded. Actual compatibility depends on the pin material, hardness, profile, and manufacturer specifications.
The reference instrument is designed to leave a smoother cut end compared with conventional orthopedic implant cutters.
The cutting mechanism is intended to minimize the formation of an excessively irregular or projecting pin end during appropriate use.
The resulting cut surface should still be inspected by the surgeon to determine whether additional finishing or adjustment is required.
The reference cutter is specified to cut approximately 5 mm below the face of the cutting head.
This dimension is relevant when positioning the instrument around a fixation pin and planning the final cut position.
The surgeon should account for the instrument geometry and required remaining pin length before cutting.
The instrument incorporates two telescopic handles that allow its overall length to change between an extended configuration of 470 mm and a retracted configuration of 340 mm.
The extended arrangement provides the longer handling profile, while the shortened configuration reduces the overall instrument dimensions for storage and reprocessing preparation.
The reference manufacturer identifies the shorter configuration as suitable for fitting into many autoclaves. Compatibility with a specific sterilizer and processing cycle must be verified before use.
The cutting head is designed to be disassembled for cleaning according to the reference manufacturer's instructions.
This feature provides access to components that may require cleaning and inspection after orthopedic pin cutting.
Disassembly, cleaning, inspection, and reassembly must follow product-specific instructions to maintain proper cutting mechanism function.
The Safety Implant Cutter is manufactured from stainless steel and is intended for repeated surgical use when maintained and processed according to the applicable instructions.
The instrument combines a compact cutting head, articulated working mechanism, and elongated telescopic handles.
Its metallic surgical finish distinguishes it from industrial-finish orthopedic cutters that may have different reprocessing and corrosion-resistance characteristics.
The Safety Implant Cutter is particularly relevant to veterinary external skeletal fixation procedures requiring trimming of compatible fixation pins.
External fixation systems use pins and connecting structures to support fracture stabilization. During selected procedures, excess pin length may require cutting after the fixation construct has been positioned.
The instrument's retained-fragment head is designed to reduce the risk of detached metal sections being projected during cutting.
The cutter may also be used during selected orthopedic procedures requiring shortening of compatible metallic fixation components within the specified cutting capacity.
Instrument selection should consider implant material, diameter, operative access, and the required final cut configuration.
The cutter is not intended for every orthopedic implant or wire type. Compatibility must be confirmed before use.
The Safety Implant Cutter may be included in veterinary orthopedic instrument trays used during fracture fixation and external fixation management.
It is relevant to veterinary orthopedic surgeons, specialist animal hospitals, veterinary surgical clinics, and veterinary procurement professionals.
Conventional pin cutters are designed to shorten compatible orthopedic pins by applying cutting force through opposing jaws.
The Safety Implant Cutter incorporates an additional retained-fragment head designed to temporarily capture the detached pin end.
The reference instrument is also designed to produce a smoother cut finish and features telescopic handles that reduce its overall length for storage and processing preparation.
These design features make it a specialized alternative to standard cutters for selected orthopedic pin-cutting applications.
| Product Name | Safety Implant Cutter |
|---|---|
| Reference Catalog Number | 001229 |
| Instrument Type | Orthopedic Safety Pin and Implant Cutter |
| Material | Stainless Steel |
| Maximum Cutting Capacity | 4.0 mm |
| Retracted Length | 340 mm / 34 cm |
| Extended Length | 470 mm / 47 cm |
| Working Head | Safety Cutting Head |
| Cutting Position | 5 mm Below Cutter Face |
| Fragment Retention | Temporary Retention Inside Cutting Head |
| Handle Configuration | Dual Telescopic Handles |
| Cleaning Feature | Disassemblable Cutting Head |
| Surface Finish | Surgical Finish |
| Reusable | Yes, According to Reference Catalog |
| Primary Specialty | Veterinary Orthopedic Surgery |
| Primary Application | External Fixation Pin and Compatible Implant Cutting |
| Unit of Measure | Each |
Before clinical use, inspect the cutting head, cutting surfaces, mechanical joints, and telescopic handles for visible wear, damage, or deformation.
Verify that the cutting mechanism operates as intended and that the telescopic handles move and secure correctly.
Inspect the fragment-retention area and remove any retained metal fragments according to the applicable manufacturer instructions.
The reference instrument features a head that can be disassembled for cleaning. Follow the manufacturer's prescribed disassembly, cleaning, inspection, and reassembly procedures.
Clean and sterilize the instrument according to the applicable product-specific instructions and the veterinary facility's validated reprocessing procedures.
The retracted 340 mm configuration is designed to fit many autoclaves, but actual chamber clearance and validated cycle compatibility must be confirmed for the specific equipment.
Do not assume particular sterilization temperatures, exposure times, processing pressures, or cleaning-agent compatibility without verified product instructions.
Peak Surgicals supplies orthopedic and veterinary surgical instruments for animal hospitals, veterinary orthopedic departments, surgical clinics, distributors, and medical procurement professionals.
When selecting this instrument, specify the Safety Implant Cutter with 4 mm maximum cutting capacity, telescopic 340–470 mm handles, and retained-fragment cutting head.
Explore related Orthopedic Instruments and Veterinary Surgical Instruments for additional pin cutters, wire cutters, and instruments used in fracture fixation procedures.
It is designed for cutting compatible orthopedic fixation pins and implants, particularly during veterinary external skeletal fixation procedures.
The reference instrument has a maximum specified cutting capacity of 4.0 mm.
The cutting head is designed to temporarily retain the separated pin end rather than allowing it to fly away during cutting.
The telescopic handles allow the overall length to change between 340 mm when retracted and 470 mm when extended.
The reference catalog specifies a cutting position approximately 5 mm below the face of the cutter.
The reference cutter features a disassemblable head for cleaning. Follow the manufacturer's product-specific instructions for disassembly and reprocessing.
Yes. The reference instrument is described as reusable stainless steel, subject to appropriate cleaning, inspection, maintenance, and validated reprocessing.