Přejít na informace o produktu
1 z 3

PEAK SURGICALS

Endoscopic Forehead Corrugator Scissors

Endoscopic Forehead Corrugator Scissors

SKU:PS-J-178

Běžná cena $768.90 USD
Běžná cena Výprodejová cena $768.90 USD
Sleva Vyprodáno
Včetně daní. Poštovné se vypočítá na pokladně.
Množství
Secure Checkout Protected payment flow
Quality Inspected Checked before dispatch
Worldwide Supply International buyer support
Shipping, Returns & Payments Clear buyer information before checkout.
Shipping
Free shipping on orders over $99. See shipping details
Returns
Returns and exchanges are handled according to our return policy. See return policy
Payments
American Express Apple Pay Diners Club Discover Google Pay JCB Mastercard
Zobrazit veškeré podrobnosti

Endoscopic Forehead Corrugator Scissors – 15cm Curved Left

The Endoscopic Forehead Corrugator Scissors are specialized surgical scissors designed for dissection of the corrugator supercilii muscle during selected endoscopic forehead and brow-lift procedures. Featuring a curved-left cutting blade, straight malleable insulated shaft, and in-line ergonomic handle, this instrument provides a dedicated configuration for endoscopic facial surgery.

The instrument features a 6-inch (15 cm) shaft and a fine curved working end designed for corrugator muscle dissection through a lateral frontal incision. Its specialized handle allows controlled opening and closing of the cutting blades through thumb-and-index-finger manipulation.

Instrument Design and Features

Curved-Left Cutting Blade

The Endoscopic Corrugator Scissors feature fine cutting blades with a left-curved working configuration. This blade pattern is intended for dissection of the corrugator muscle during selected endoscopic forehead procedures.

The curved working end provides an alternative to straight-bladed endoscopic scissors when the operative technique requires this blade orientation.

Cutting direction, blade positioning, and tissue selection must be determined by the surgeon according to the planned procedure and relevant anatomy.

Straight Malleable Insulated Shaft

The instrument incorporates a 15 cm straight malleable shaft with insulation. The malleable construction allows the shaft to be adjusted within the limits specified by the applicable manufacturer instructions.

The insulated shaft separates the working end from the handle and provides a specialized instrument profile for selected endoscopic surgical approaches.

Insulation is a verified construction feature but does not independently establish electrosurgical compatibility. The instrument should not be connected to powered surgical equipment without specific manufacturer authorization.

In-Line Ergonomic Handle

A distinctive feature of the instrument is its in-line ergonomic handle with two opposing perforated control arms.

The handle is designed for operation through movements of the thumb and index finger. Its configuration allows the surgeon to adjust grip and hand position while manipulating the cutting blades.

Unlike conventional ring-handled scissors, the instrument does not rely on circular finger loops for blade operation.

The handle is intended to provide tactile feedback during instrument manipulation, allowing the operator to control the opening and closing movement of the working end.

Flush-Port Assembly

The illustrated instrument features a flush-port opening near the junction between the shaft and ergonomic handle.

This port is associated with instrument maintenance and processing. Its exact cleaning method, flushing accessories, and permitted processing parameters must follow the relevant product-specific instructions.

Clinical Applications in Endoscopic Forehead Surgery

Corrugator Supercilii Muscle Dissection

The Endoscopic Forehead Corrugator Scissors are designed for surgical dissection of the corrugator supercilii muscle through the lateral frontal incision.

The corrugator supercilii is a muscle associated with eyebrow movement and glabellar facial expression. Selected endoscopic forehead procedures may involve surgical manipulation or division of corrugator muscle tissue according to the operative plan.

The fine curved cutting blades provide a specialized working end for the relevant dissection steps.

The surgeon determines the extent of muscle dissection and instrument placement based on anatomical structures and the intended technique.

Endoscopic Brow-Lift Procedures

Endoscopic brow-lift surgery may involve dissection and release of selected forehead structures. Corrugator muscle dissection can form part of the surgical approach when indicated.

The curved-left cutting configuration and 15 cm malleable shaft provide an instrument option for these procedures.

The instrument is relevant to facial plastic surgeons, aesthetic surgical practices, reconstructive surgery departments, and facilities performing endoscopic forehead procedures.

Endoscopic Corrugator Scissors vs. Periosteal Scissors

Corrugator scissors and periosteal scissors are separate endoscopic instrument patterns with different intended surgical applications.

The Corrugator Scissors, reference B 65092, feature a curved-left blade and straight malleable shaft for corrugator muscle dissection.

The related Periosteal Scissors, reference B 65090, feature a straight blade and curved malleable shaft for dissection of periosteal tissue around the arcus marginalis and superolateral orbital rim.

These instruments should be identified and selected according to their verified blade configurations and intended surgical functions.

Product Specifications

Product Name Endoscopic Forehead Corrugator Scissors
Reference Pattern SofTouch Endoscopic Corrugator Scissors
Catalog Reference B 65092
Instrument Type Endoscopic Dissecting Scissors
Shaft Length 6 inches / 15 cm
Blade Configuration Curved Left
Shaft Configuration Straight, Malleable
Shaft Insulation Insulated
Handle Design In-Line Ergonomic Handle
Handle Operation Thumb and Index Finger Control
Additional Feature Flush Port
Primary Specialty Endoscopic Plastic and Facial Surgery
Clinical Application Corrugator Supercilii Muscle Dissection
Associated Procedure Endoscopic Forehead and Brow-Lift Surgery

Instrument Inspection and Handling

Before clinical use, inspect the curved cutting blades for visible damage, deformation, or wear. Examine the narrow shaft and its insulation for surface irregularities or structural defects.

Check the ergonomic handle and control arms for appropriate mechanical movement. Verify that the cutting blades open and close correctly according to the applicable manufacturer instructions.

Inspect the flush-port opening and surrounding assembly for visible obstruction or damage.

Clean and process the instrument according to product-specific manufacturer instructions and the healthcare facility's validated instrument-reprocessing procedures.

Particular attention should be given to the fine cutting end, shaft insulation, handle mechanism, and flush-port assembly.

Do not assume specific sterilization temperatures, exposure times, flushing pressures, or cleaning-agent compatibility without verified product instructions.

During transportation and storage, protect the delicate cutting blades, insulated shaft, and handle mechanism from mechanical damage.

Ordering Endoscopic Forehead Corrugator Scissors

Peak Surgicals supplies surgical instruments for hospitals, facial plastic surgery practices, endoscopic forehead surgery departments, aesthetic surgical clinics, distributors, and medical procurement professionals.

For accurate product identification, specify the 15 cm straight malleable shaft, insulated construction, curved-left cutting blade, and in-line ergonomic handle.

The corresponding reference catalog model is B 65092. Confirm the supplied instrument configuration and inventory details when ordering.

Explore related Endoscopic Face and Forehead Lift Instruments for additional surgical scissors, dissectors, elevators, graspers, and instruments used in endoscopic facial surgery.

Frequently Asked Questions

1. What are Endoscopic Forehead Corrugator Scissors used for?

They are designed for dissection of the corrugator supercilii muscle through a lateral frontal incision during selected endoscopic forehead procedures.

2. What is the shaft length?

The instrument features a 6-inch (15 cm) malleable shaft.

3. Are the scissors straight or curved?

The scissors have a curved-left cutting blade and a straight malleable shaft.

4. Does the instrument feature an insulated shaft?

Yes. The reference configuration includes an insulated malleable shaft.

5. What type of handle does the instrument have?

It features an in-line ergonomic handle designed for thumb-and-index-finger manipulation.

6. What is the reference model for these scissors?

The reference model is B 65092, identifying the 15 cm Endoscopic Forehead Corrugator Scissors with a curved-left blade and straight malleable shaft.