Scipeáil chuig faisnéis an táirge
1 de 3

PEAK SURGICALS

Stille-Liston Bone Cutting Forceps – 267 mm Curved Double-Action Orthopedic Bone Cutter

Stille-Liston Bone Cutting Forceps – 267 mm Curved Double-Action Orthopedic Bone Cutter

SKU:PS-000030

Gnáthphraghas $75.89 USD
Gnáthphraghas Praghas díola $75.89 USD
Díol Díolta amach
Cáin san áireamh. Loingseoireacht á ríomh ag an tseiceáil amach.
Cainníocht
Secure Checkout Protected payment flow
Quality Inspected Checked before dispatch
Worldwide Supply International buyer support
Shipping, Returns & Payments Clear buyer information before checkout.
Shipping
Free shipping on orders over $99. See shipping details
Returns
Returns and exchanges are handled according to our return policy. See return policy
Payments
American Express Apple Pay Diners Club Discover Google Pay JCB Mastercard
Féach ar shonraí iomlána

Stille-Liston Bone Cutting Forceps, SKU PS-000030, are reusable orthopedic bone cutters designed for controlled cutting, trimming, and removal of exposed bone during trauma, reconstructive, and general orthopedic procedures. The instrument measures 267 mm overall, approximately 10 1/2 in, and combines curved cutting jaws with a double-action compound-leverage mechanism. This mechanical design multiplies force generated at the handles before transferring it to the distal cutting edges, allowing dense or moderately thick bone to be divided with greater mechanical efficiency than a conventional single-action cutter. The curved jaw profile provides an offset approach to the target bone when straight-line access is limited by surrounding anatomy, retractors, implants, or the operative corridor. Stille-Liston Bone Cutting Forceps are used during fracture surgery, osteotomy, bone contouring, removal of accessible osseous projections, reconstructive procedures, and other workflows requiring substantial but controlled cutting force. Peak Surgicals lists this pattern as reusable, latex-free, and manufactured from medical-grade steel for repeated professional surgical use.

Curved Cutting Jaws and Double-Action Leverage Mechanism

The principal mechanical feature of the Stille-Liston Bone Cutting Forceps is the double-action linkage positioned between the handles and cutting jaws. Initial handle closure activates an intermediate pivot system that multiplies mechanical force before the sharpened jaw edges meet the bone. This compound-action design allows the operator to generate greater distal cutting pressure without depending solely on hand strength. The curved working profile changes the approach angle between the handles and the target osseous surface, making the instrument useful where a straight cutter would place the surgeon's hands directly over the operative site or conflict with adjacent instrumentation. Established Stille-Liston jaws use sharpened inner cutting surfaces with rounded external contours, allowing the bone to be captured between the working edges before compression is completed. The surgeon should fully position the target bone within the cutting area before applying substantial pressure. Because this is a manually controlled cutting forceps rather than a powered device, progression remains governed by jaw placement, handle closure, bone resistance, visualization, and repeated assessment of the intended resection.

Orthopedic Bone Resection and Reconstruction Workflow

During orthopedic fracture surgery, the Stille-Liston Bone Cutting Forceps can be introduced after adequate exposure has provided direct visualization of the bone requiring trimming or removal. The curved jaws are positioned around the selected osseous projection, fragment, or cortical margin, and gradual handle compression activates the double-action mechanism until the cutting edges divide the intended section. This pattern can assist removal of irregular bone margins during trauma reconstruction, refinement of exposed bone before fixation, and controlled resection of accessible osteophytes or other projections. During osteotomy or reconstructive procedures, the instrument may be used to contour bone where substantial manual leverage is required but powered cutting equipment is unnecessary or unsuitable for the specific step. The 267 mm length provides useful working reach while allowing the handles to remain outside the deepest part of the operative field. Bone should be removed incrementally rather than by attempting to capture an excessively large section in one cut. Soft tissue, neurovascular structures, tendons, periosteum, implants, and fixation hardware should remain outside the cutting path before jaw closure.

PS-000030 267 mm Curved Pattern and Instrument Selection

Peak Surgicals SKU PS-000030 identifies the 267 mm curved Stille-Liston Bone Cutting Forceps with a double-action mechanism. This measurement corresponds to approximately 10 1/2 inches and matches an established curved Stille-Liston configuration used across orthopedic instrument catalogs. The curved design should be distinguished from Peak Surgicals' separate 28 cm straight Liston-Stille Bone Cutting Forceps, because jaw orientation materially changes surgical access and handling. A curved model is advantageous when the surgeon must approach an exposed bone margin from an offset angle or keep the handles away from adjacent structures. A straight Stille-Liston pattern is more appropriate when direct axial access to the target bone is available. Stille-Liston forceps are also mechanically heavier-duty than compact single-action patterns such as Markwalder cutters. PS-000030 should therefore be selected according to bone density, operative depth, required leverage, jaw approach, and available surgical clearance. Hospitals should retain the SKU, 267 mm length, curved-jaw designation, and double-action mechanism in procurement and tray records.

Medical-Grade Steel, Reprocessing and Procurement Standards

Medical-grade stainless steel provides the strength, corrosion resistance, edge stability, and structural rigidity required for reusable bone-cutting forceps exposed to repeated cutting loads and sterilization cycles. Reprocessing should begin promptly after clinical use so blood, marrow, bone particles, and tissue residue do not dry within the curved cutting jaws, compound-action pivots, spring areas, or handle surfaces. The instrument should remain sufficiently open during cleaning to provide access to the cutting edges and articulated mechanisms. Thorough rinsing and complete drying should follow before visual and functional inspection. Sterile-processing personnel should assess blade alignment, cutting-edge integrity, joint movement, corrosion, cracks, deformation, or excessive wear. The double-action linkage should operate smoothly without binding or excessive looseness. Moving joints may receive instrument-compatible lubrication according to the healthcare facility's validated maintenance procedure. Terminal sterilization should follow the facility's validated process for reusable stainless steel surgical instruments. Peak Surgicals displays CE, FDA, and ISO certification information and supports ISO 13485 procurement documentation, while specific FDA status should be retained through exact manufacturer or device records rather than presented as unsupported individual FDA approval.

SKU PS-000030
Product Name Stille-Liston Bone Cutting Forceps
Price $75.89 USD
Size/Gauge Variants 267 mm overall length, approximately 10 1/2 in
Jaw Configuration Curved Cutting Jaws
Mechanism Double-Action Compound Leverage
Instrument Category Orthopedic Bone Cutting Forceps
Procedure Fracture surgery, orthopedic bone resection, osteotomy, bone contouring, osseous fragment removal, and reconstructive surgery
Material Medical-Grade Stainless Steel
Finish Surgical Instrument Finish
Sterilization Reusable; sterilize following validated healthcare-facility cleaning and reprocessing protocols
Instrument Classification Reusable Manual Orthopedic Bone Cutting Forceps
Reusable Yes
Latex-Free Yes
Certifications CE, ISO 13485, FDA-related procurement documentation
Warranty 30-Day Money-Back Guarantee on eligible purchases
MOQ 1 Piece for standard online ordering
OEM / Custom Orders Available for institutional, distributor, and custom procurement requirements
After-Sale Service Return and replacement support under Peak Surgicals policy

How do Stille-Liston Bone Cutting Forceps differ from Ruskin-Liston Bone Cutting Forceps?
Stille-Liston Bone Cutting Forceps use a larger, heavier double-action design intended to generate substantial cutting leverage during orthopedic bone work. Ruskin-Liston forceps are generally shorter and use smaller jaws for more controlled cutting of relatively small or delicate osseous structures. PS-000030 measures 267 mm and therefore provides considerably more working reach than compact Ruskin-Liston patterns. Both designs use compound-action leverage to increase cutting pressure at the jaws. The Stille-Liston configuration is more suitable when the procedure requires greater cutting capacity or deeper access. Selection should reflect bone size, density, surgical depth, required leverage, and available working space.

Why select the curved 267 mm Stille-Liston pattern instead of a straight model?
The curved jaws allow the cutting end to approach an exposed bone surface from an offset angle. This can preserve clearance when the target lies behind adjacent anatomy, retractors, plates, or other instruments. A straight Stille-Liston cutter is preferable when the surgeon has direct axial access and wants the cutting jaws aligned with the handle body. The 267 mm length also provides useful leverage and reach for deeper orthopedic fields. Peak Surgicals maintains a separate 28 cm straight Liston-Stille product, so these patterns should not be treated as identical. PS-000030 should be selected when curved access, double-action leverage, and approximately 10.5-inch working length match the planned procedure.

What do CE, ISO 13485 and FDA references mean for procurement?
Peak Surgicals displays CE, FDA, and ISO certification information for the Stille-Liston Bone Cutting Forceps. ISO 13485 concerns quality-management processes used in medical-device manufacturing and does not by itself prove the clinical performance of an individual instrument. CE documentation supports applicable conformity-assessment requirements within relevant medical-device markets. FDA AccessGUDID includes commercially distributed Stille-Liston Bone Cutting Forceps in curved, straight, and angled configurations. Those database records belong to specific manufacturers and catalog numbers and should not automatically be assigned to PS-000030 unless the device identity matches exactly. Hospitals and distributors should retain supplier certificates, the Peak SKU, applicable regulatory documentation, and purchasing records within their vendor-qualification files.

How does the double-action mechanism improve cutting force?
The double-action mechanism uses a compound linkage between the handles and cutting jaws. As the surgeon closes the handles, force is transferred through more than one pivot before reaching the distal blades. This increases mechanical advantage and allows greater cutting pressure to be generated with less direct hand effort than a simple single-action forceps. The mechanism is especially useful when moderately dense or thicker bone requires controlled manual division. Increased leverage does not mean that an excessively large bone segment should be captured in one closure. The surgeon should still position the jaws carefully, cut incrementally, and reassess the bone and surrounding structures after each cutting cycle.

How should hospitals order and reprocess the Stille-Liston Bone Cutting Forceps?
Hospitals should order this exact product using Peak Surgicals SKU PS-000030 together with the 267 mm length, curved-jaw, and double-action specifications. Peak Surgicals currently lists the instrument at $75.89 and displays a 30-day money-back guarantee. The separate 28 cm straight Liston-Stille product should not be substituted unless a straight configuration is specifically required. Following surgery, blood, marrow, bone fragments, and tissue residue should be removed promptly from the curved cutting blades, compound joints, springs, and handles. Cleaning should be followed by thorough rinsing, complete drying, inspection of cutting-edge alignment and mechanism function, and instrument-compatible lubrication where required. Final sterilization should follow the healthcare facility's validated reusable surgical-instrument process before PS-000030 returns to the orthopedic bone-cutting tray.