{"product_id":"lesser-wire-passer-retrieval-forceps","title":"Lesser Wire Passer \u0026 Retrieval Forceps","description":"\n\u003ch2\u003eLesser Wire Passer \u0026amp; Retrieval Forceps – 150mm \u0026amp; 190mm\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eLesser Wire Passer and Retrieval Forceps\u003c\/strong\u003e are specialized veterinary orthopedic instruments designed to combine tissue-protecting drill guidance with wire and suture retrieval. Featuring an open-sided toothed guide tube, opposing retrieval jaws, and ring handles, this instrument assists with selected orthopedic fixation procedures.\u003c\/p\u003e\n\n\u003cp\u003eAvailable in \u003cstrong\u003e150 mm (15 cm)\u003c\/strong\u003e and \u003cstrong\u003e190 mm (19 cm)\u003c\/strong\u003e lengths, the Lesser pattern is particularly associated with hemi-cerclage and the passage of lateral sutures through the tibial crest.\u003c\/p\u003e\n\n\u003cp\u003eThe original instrument design is attributed to Arnie Lesser.\u003c\/p\u003e\n\n\u003ch2\u003eInstrument Design and Features\u003c\/h2\u003e\n\n\u003ch3\u003eOpen-Sided Drill Guide\u003c\/h3\u003e\n\n\u003cp\u003eThe Lesser Wire Passer incorporates an open-sided guide tube designed to assist with drill positioning during selected veterinary orthopedic procedures.\u003c\/p\u003e\n\n\u003cp\u003eThe open guide configuration allows the instrument to be disengaged from the wire or suture without requiring the entire material length to pass through a closed tube.\u003c\/p\u003e\n\n\u003cp\u003eThe guide also serves as a tissue-protecting interface during the relevant surgical stage. Appropriate positioning and drill compatibility must be confirmed by the operating surgeon.\u003c\/p\u003e\n\n\u003ch3\u003eToothed Guide-Tube Contact End\u003c\/h3\u003e\n\n\u003cp\u003eThe working end of the guide tube features a toothed contact surface intended to reduce drill skating during initial positioning.\u003c\/p\u003e\n\n\u003cp\u003eThe teeth provide a defined contact profile against the selected bone surface when used according to the intended technique.\u003c\/p\u003e\n\n\u003cp\u003eDrill selection, guide positioning, and surrounding tissue protection remain dependent on the surgical anatomy and the manufacturer's instructions.\u003c\/p\u003e\n\n\u003ch3\u003eIntegrated Wire Retrieval Mechanism\u003c\/h3\u003e\n\n\u003cp\u003eThe forceps combine a drill-guiding function with a mechanism intended to capture wire or suture material on the opposite side of the operative site.\u003c\/p\u003e\n\n\u003cp\u003eThe retrieval arrangement allows the surgeon to engage and withdraw the selected material during an appropriate orthopedic technique.\u003c\/p\u003e\n\n\u003cp\u003eThis combination distinguishes the Lesser instrument from conventional closed-eye wire passers and ordinary surgical grasping forceps.\u003c\/p\u003e\n\n\u003ch3\u003eDouble Ring Handles\u003c\/h3\u003e\n\n\u003cp\u003eThe instrument features two circular finger rings connected to elongated forceps arms.\u003c\/p\u003e\n\n\u003cp\u003eThe hinged configuration provides manual control of the retrieval mechanism during positioning and instrument manipulation.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument should be operated according to its intended design to avoid excessive force on the working end or adjacent tissue structures.\u003c\/p\u003e\n\n\u003ch2\u003eAvailable Sizes\u003c\/h2\u003e\n\n\u003ch3\u003eLesser Wire Passer – Standard 150mm\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e150 mm Lesser Wire Passer and Retrieval Forceps\u003c\/strong\u003e, supplier reference 001268, is the shorter configuration.\u003c\/p\u003e\n\n\u003cp\u003eThe reference manufacturer's current product title identifies this configuration with a 5–15 mm guide-size range.\u003c\/p\u003e\n\n\u003cp\u003eThe standard model is intended for selected veterinary orthopedic procedures where its dimensions are suitable for the surgical approach.\u003c\/p\u003e\n\n\u003ch3\u003eLesser Wire Passer – Large 190mm\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e190 mm Lesser Wire Passer and Retrieval Forceps\u003c\/strong\u003e, supplier reference 001269, provides a longer instrument configuration.\u003c\/p\u003e\n\n\u003cp\u003eThe reference manufacturer identifies the Large model with a 10–25 mm guide-size range.\u003c\/p\u003e\n\n\u003cp\u003eSelection between the 150 mm and 190 mm instruments depends on the operative anatomy, required access, and selected surgical technique.\u003c\/p\u003e\n\n\u003ch2\u003eClinical Applications in Veterinary Orthopedic Surgery\u003c\/h2\u003e\n\n\u003ch3\u003eHemi-Cerclage Procedures\u003c\/h3\u003e\n\n\u003cp\u003eThe Lesser Wire Passer is associated with hemi-cerclage techniques used in selected veterinary orthopedic fixation procedures.\u003c\/p\u003e\n\n\u003cp\u003eIts combined guiding and retrieval functions assist the surgeon with positioning and recovering the selected wire or suture material.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument does not independently tension, twist, or cut orthopedic wire. Appropriate fixation equipment must be selected separately according to the procedure.\u003c\/p\u003e\n\n\u003ch3\u003eLateral Suture Passage Through the Tibial Crest\u003c\/h3\u003e\n\n\u003cp\u003eThe instrument is also designed for selected procedures involving the passage of lateral sutures through the tibial crest.\u003c\/p\u003e\n\n\u003cp\u003eThe open-sided drill guide provides a positioning interface, while the forceps mechanism is intended to capture material on the opposite side of the passage.\u003c\/p\u003e\n\n\u003cp\u003eThe surgeon should determine the appropriate drilling location, wire or suture pathway, and fixation technique based on the patient's anatomy.\u003c\/p\u003e\n\n\u003ch3\u003eVeterinary Orthopedic Fixation\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eLesser Orthopedic Wire Retrieval Forceps\u003c\/strong\u003e may be included in veterinary orthopedic instrument trays used for selected bone fixation and suture-passing procedures.\u003c\/p\u003e\n\n\u003cp\u003eThey are relevant to veterinary orthopedic surgeons, specialist animal hospitals, veterinary surgical facilities, and procurement professionals sourcing orthopedic instrumentation.\u003c\/p\u003e\n\n\u003ch2\u003eLesser Wire Passer vs. Conventional Wire Passer\u003c\/h2\u003e\n\n\u003cp\u003eConventional orthopedic wire passers are primarily designed to guide cerclage wire around selected bone structures.\u003c\/p\u003e\n\n\u003cp\u003eThe Lesser Wire Passer combines a tissue-protecting drill guide with a retrieval mechanism designed to capture wire or suture material from the opposite side of the operative site.\u003c\/p\u003e\n\n\u003cp\u003eIts open-sided guide tube and toothed contact surface provide additional instrument features not found on every conventional wire passer.\u003c\/p\u003e\n\n\u003cp\u003eThe appropriate instrument should be selected according to the surgical technique and required wire-passing method.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eLesser Wire Passer and Retrieval Forceps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument Pattern\u003c\/th\u003e\n\u003ctd\u003eLesser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOriginal Design\u003c\/th\u003e\n\u003ctd\u003eArnie Lesser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstrument Type\u003c\/th\u003e\n\u003ctd\u003eOrthopedic Wire and Suture Retrieval Forceps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAvailable Lengths\u003c\/th\u003e\n\u003ctd\u003e150 mm and 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard Configuration\u003c\/th\u003e\n\u003ctd\u003e150 mm \/ 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLarge Configuration\u003c\/th\u003e\n\u003ctd\u003e190 mm \/ 19 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard Reference\u003c\/th\u003e\n\u003ctd\u003e001268\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLarge Reference\u003c\/th\u003e\n\u003ctd\u003e001269\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide Design\u003c\/th\u003e\n\u003ctd\u003eOpen-Sided Drill Guide Tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGuide Contact Surface\u003c\/th\u003e\n\u003ctd\u003eToothed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWorking Mechanism\u003c\/th\u003e\n\u003ctd\u003eWire and Suture Retrieval Forceps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHandle Configuration\u003c\/th\u003e\n\u003ctd\u003eDouble Finger-Ring Handles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePrimary Functions\u003c\/th\u003e\n\u003ctd\u003eDrill Guidance, Tissue Protection and Wire Retrieval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePrimary Specialty\u003c\/th\u003e\n\u003ctd\u003eVeterinary Orthopedic Surgery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClinical Applications\u003c\/th\u003e\n\u003ctd\u003eHemi-Cerclage and Lateral Suture Passage Through the Tibial Crest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUnit of Measure\u003c\/th\u003e\n\u003ctd\u003eEach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstrument Inspection and Reprocessing\u003c\/h2\u003e\n\n\u003cp\u003eBefore clinical use, inspect the open-sided guide tube, toothed contact surface, retrieval jaws, and hinged mechanism for visible damage or deformation.\u003c\/p\u003e\n\n\u003cp\u003eConfirm that the forceps open and close correctly and that the guide-tube opening is free from obstruction.\u003c\/p\u003e\n\n\u003cp\u003eClean and process the instrument according to the applicable manufacturer's product-specific instructions and the veterinary facility's validated reprocessing procedures.\u003c\/p\u003e\n\n\u003cp\u003eParticular attention should be given to the guide-tube interior, working-end teeth, joints, and areas where surgical debris may accumulate.\u003c\/p\u003e\n\n\u003cp\u003eDo not assume specific sterilization temperatures, exposure times, cleaning-agent compatibility, or material grades without verified product documentation.\u003c\/p\u003e\n\n\u003ch2\u003eOrdering Lesser Wire Passer \u0026amp; Retrieval Forceps\u003c\/h2\u003e\n\n\u003cp\u003ePeak Surgicals supplies orthopedic and veterinary surgical instruments for animal hospitals, veterinary orthopedic clinics, specialist surgical facilities, distributors, and medical procurement professionals.\u003c\/p\u003e\n\n\u003cp\u003eChoose the required \u003cstrong\u003e150 mm Standard\u003c\/strong\u003e or \u003cstrong\u003e190 mm Large\u003c\/strong\u003e configuration according to the intended veterinary orthopedic procedure.\u003c\/p\u003e\n\n\u003cp\u003eExplore related \u003ca href=\"\/pt\/collections\/veterinary-surgical-instruments\"\u003eVeterinary Surgical Instruments\u003c\/a\u003e and \u003ca href=\"\/pt\/collections\/orthopedic-instruments\"\u003eOrthopedic Instruments\u003c\/a\u003e for additional wire passers, reduction forceps, cerclage instruments, and fracture fixation tools.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003e1. What are Lesser Wire Passer and Retrieval Forceps used for?\u003c\/h3\u003e\n\u003cp\u003eThey combine tissue-protecting drill guidance with wire or suture retrieval during selected veterinary orthopedic fixation procedures.\u003c\/p\u003e\n\n\u003ch3\u003e2. Which sizes are available?\u003c\/h3\u003e\n\u003cp\u003eThe documented configurations are 150 mm Standard and 190 mm Large.\u003c\/p\u003e\n\n\u003ch3\u003e3. What is the purpose of the open-sided guide tube?\u003c\/h3\u003e\n\u003cp\u003eThe open-sided tube provides a drill-guiding interface and allows the instrument to be disengaged from the selected wire or suture.\u003c\/p\u003e\n\n\u003ch3\u003e4. Why does the guide tube have teeth?\u003c\/h3\u003e\n\u003cp\u003eThe toothed contact surface is intended to reduce drill skating during guide positioning.\u003c\/p\u003e\n\n\u003ch3\u003e5. Which procedures commonly use this instrument?\u003c\/h3\u003e\n\u003cp\u003eThe reference manufacturer identifies hemi-cerclage and lateral suture passage through the tibial crest as common applications.\u003c\/p\u003e\n\n\u003ch3\u003e6. What are the supplier catalog references?\u003c\/h3\u003e\n\u003cp\u003eThe Standard 150 mm model is reference 001268, and the Large 190 mm model is reference 001269.\u003c\/p\u003e\n","brand":"PEAK SURGICALS","offers":[{"title":"Standard – 150mm","offer_id":57628222652580,"sku":"PS-J-196","price":65.99,"currency_code":"USD","in_stock":true},{"title":"Large – 190mm","offer_id":57628222685348,"sku":"PS-J-197","price":65.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/files\/1_8850271f-103e-4c29-9cb0-7cd840c0cce2.jpg?v=1795517340","url":"https:\/\/peaksurgicals.com\/pt\/products\/lesser-wire-passer-retrieval-forceps","provider":"PEAK SURGICALS","version":"1.0","type":"link"}