{"product_id":"safety-implant-cutter-4mm-capacity-telescopic-handles","title":"Safety Implant Cutter – 4mm Capacity, Telescopic Handles","description":"\n\u003ch2\u003eSafety Implant Cutter – 4mm Capacity with Telescopic Handles\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSafety Implant Cutter with Telescopic Handles\u003c\/strong\u003e is a reusable stainless steel veterinary orthopedic instrument designed for cutting compatible fixation pins and implants up to 4 mm in diameter. Featuring a specialized safety cutting head, telescopic handles, and a removable head assembly, it provides a dedicated configuration for orthopedic pin trimming.\u003c\/p\u003e\n\n\u003cp\u003eThe cutter has a maximum cutting capacity of \u003cstrong\u003e4.0 mm\u003c\/strong\u003e and is designed to produce a smoother cut end than a conventional cutter. The separated pin fragment is temporarily retained within the cutting head rather than being released freely into the surrounding surgical area.\u003c\/p\u003e\n\n\u003cp\u003eThe telescopic handle arrangement allows the overall instrument length to be reduced from \u003cstrong\u003e470 mm to 340 mm\u003c\/strong\u003e for storage and reprocessing preparation.\u003c\/p\u003e\n\n\u003ch2\u003eInstrument Design and Features\u003c\/h2\u003e\n\n\u003ch3\u003eSafety Cutting Head with Fragment Retention\u003c\/h3\u003e\n\n\u003cp\u003eThe primary distinguishing feature of the Safety Implant Cutter is its specialized cutting head, which temporarily retains the separated end of a fixation pin after cutting.\u003c\/p\u003e\n\n\u003cp\u003eDuring orthopedic procedures, conventional cutting instruments may release small metal fragments when a pin is shortened. The reference cutter is designed to retain the detached section within its head, reducing the risk of an uncontrolled fragment being projected away from the cutting site.\u003c\/p\u003e\n\n\u003cp\u003eThe retained fragment must be removed and accounted for according to the applicable instrument instructions and surgical facility procedures.\u003c\/p\u003e\n\n\u003ch3\u003eMaximum 4mm Cutting Capacity\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e4mm Safety Implant Cutter\u003c\/strong\u003e is specified for compatible orthopedic fixation pins with a maximum diameter of 4.0 mm.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument may be used for cutting selected pins associated with external skeletal fixation systems and other orthopedic applications where the material and diameter are compatible.\u003c\/p\u003e\n\n\u003cp\u003eThe maximum cutting capacity must not be exceeded. Actual compatibility depends on the pin material, hardness, profile, and manufacturer specifications.\u003c\/p\u003e\n\n\u003ch3\u003eSmoother Surgical Cut Finish\u003c\/h3\u003e\n\n\u003cp\u003eThe reference instrument is designed to leave a smoother cut end compared with conventional orthopedic implant cutters.\u003c\/p\u003e\n\n\u003cp\u003eThe cutting mechanism is intended to minimize the formation of an excessively irregular or projecting pin end during appropriate use.\u003c\/p\u003e\n\n\u003cp\u003eThe resulting cut surface should still be inspected by the surgeon to determine whether additional finishing or adjustment is required.\u003c\/p\u003e\n\n\u003ch3\u003e5mm Recessed Cutting Position\u003c\/h3\u003e\n\n\u003cp\u003eThe reference cutter is specified to cut approximately \u003cstrong\u003e5 mm below the face of the cutting head\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThis dimension is relevant when positioning the instrument around a fixation pin and planning the final cut position.\u003c\/p\u003e\n\n\u003cp\u003eThe surgeon should account for the instrument geometry and required remaining pin length before cutting.\u003c\/p\u003e\n\n\u003ch3\u003eTelescopic Handles – 340mm to 470mm\u003c\/h3\u003e\n\n\u003cp\u003eThe instrument incorporates two telescopic handles that allow its overall length to change between an extended configuration of 470 mm and a retracted configuration of 340 mm.\u003c\/p\u003e\n\n\u003cp\u003eThe extended arrangement provides the longer handling profile, while the shortened configuration reduces the overall instrument dimensions for storage and reprocessing preparation.\u003c\/p\u003e\n\n\u003cp\u003eThe reference manufacturer identifies the shorter configuration as suitable for fitting into many autoclaves. Compatibility with a specific sterilizer and processing cycle must be verified before use.\u003c\/p\u003e\n\n\u003ch3\u003eDisassemblable Cutting Head\u003c\/h3\u003e\n\n\u003cp\u003eThe cutting head is designed to be disassembled for cleaning according to the reference manufacturer's instructions.\u003c\/p\u003e\n\n\u003cp\u003eThis feature provides access to components that may require cleaning and inspection after orthopedic pin cutting.\u003c\/p\u003e\n\n\u003cp\u003eDisassembly, cleaning, inspection, and reassembly must follow product-specific instructions to maintain proper cutting mechanism function.\u003c\/p\u003e\n\n\u003ch3\u003eReusable Stainless Steel Construction\u003c\/h3\u003e\n\n\u003cp\u003eThe Safety Implant Cutter is manufactured from stainless steel and is intended for repeated surgical use when maintained and processed according to the applicable instructions.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument combines a compact cutting head, articulated working mechanism, and elongated telescopic handles.\u003c\/p\u003e\n\n\u003cp\u003eIts metallic surgical finish distinguishes it from industrial-finish orthopedic cutters that may have different reprocessing and corrosion-resistance characteristics.\u003c\/p\u003e\n\n\u003ch2\u003eClinical Applications in Veterinary Orthopedic Surgery\u003c\/h2\u003e\n\n\u003ch3\u003eExternal Skeletal Fixation Pin Trimming\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSafety Implant Cutter\u003c\/strong\u003e is particularly relevant to veterinary external skeletal fixation procedures requiring trimming of compatible fixation pins.\u003c\/p\u003e\n\n\u003cp\u003eExternal fixation systems use pins and connecting structures to support fracture stabilization. During selected procedures, excess pin length may require cutting after the fixation construct has been positioned.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument's retained-fragment head is designed to reduce the risk of detached metal sections being projected during cutting.\u003c\/p\u003e\n\n\u003ch3\u003eOrthopedic Implant Management\u003c\/h3\u003e\n\n\u003cp\u003eThe cutter may also be used during selected orthopedic procedures requiring shortening of compatible metallic fixation components within the specified cutting capacity.\u003c\/p\u003e\n\n\u003cp\u003eInstrument selection should consider implant material, diameter, operative access, and the required final cut configuration.\u003c\/p\u003e\n\n\u003cp\u003eThe cutter is not intended for every orthopedic implant or wire type. Compatibility must be confirmed before use.\u003c\/p\u003e\n\n\u003ch3\u003eVeterinary Fracture Fixation Procedures\u003c\/h3\u003e\n\n\u003cp\u003eThe Safety Implant Cutter may be included in veterinary orthopedic instrument trays used during fracture fixation and external fixation management.\u003c\/p\u003e\n\n\u003cp\u003eIt is relevant to veterinary orthopedic surgeons, specialist animal hospitals, veterinary surgical clinics, and veterinary procurement professionals.\u003c\/p\u003e\n\n\u003ch2\u003eSafety Implant Cutter vs. Conventional Pin Cutter\u003c\/h2\u003e\n\n\u003cp\u003eConventional pin cutters are designed to shorten compatible orthopedic pins by applying cutting force through opposing jaws.\u003c\/p\u003e\n\n\u003cp\u003eThe Safety Implant Cutter incorporates an additional retained-fragment head designed to temporarily capture the detached pin end.\u003c\/p\u003e\n\n\u003cp\u003eThe reference instrument is also designed to produce a smoother cut finish and features telescopic handles that reduce its overall length for storage and processing preparation.\u003c\/p\u003e\n\n\u003cp\u003eThese design features make it a specialized alternative to standard cutters for selected orthopedic pin-cutting applications.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n      \u003ctd\u003eSafety Implant Cutter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eReference Catalog Number\u003c\/th\u003e\n      \u003ctd\u003e001229\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eInstrument Type\u003c\/th\u003e\n      \u003ctd\u003eOrthopedic Safety Pin and Implant Cutter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n      \u003ctd\u003eStainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eMaximum Cutting Capacity\u003c\/th\u003e\n      \u003ctd\u003e4.0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eRetracted Length\u003c\/th\u003e\n      \u003ctd\u003e340 mm \/ 34 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eExtended Length\u003c\/th\u003e\n      \u003ctd\u003e470 mm \/ 47 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eWorking Head\u003c\/th\u003e\n      \u003ctd\u003eSafety Cutting Head\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eCutting Position\u003c\/th\u003e\n      \u003ctd\u003e5 mm Below Cutter Face\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eFragment Retention\u003c\/th\u003e\n      \u003ctd\u003eTemporary Retention Inside Cutting Head\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eHandle Configuration\u003c\/th\u003e\n      \u003ctd\u003eDual Telescopic Handles\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eCleaning Feature\u003c\/th\u003e\n      \u003ctd\u003eDisassemblable Cutting Head\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eSurface Finish\u003c\/th\u003e\n      \u003ctd\u003eSurgical Finish\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eReusable\u003c\/th\u003e\n      \u003ctd\u003eYes, According to Reference Catalog\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003ePrimary Specialty\u003c\/th\u003e\n      \u003ctd\u003eVeterinary Orthopedic Surgery\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003ePrimary Application\u003c\/th\u003e\n      \u003ctd\u003eExternal Fixation Pin and Compatible Implant Cutting\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eUnit of Measure\u003c\/th\u003e\n      \u003ctd\u003eEach\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstrument Inspection and Reprocessing\u003c\/h2\u003e\n\n\u003cp\u003eBefore clinical use, inspect the cutting head, cutting surfaces, mechanical joints, and telescopic handles for visible wear, damage, or deformation.\u003c\/p\u003e\n\n\u003cp\u003eVerify that the cutting mechanism operates as intended and that the telescopic handles move and secure correctly.\u003c\/p\u003e\n\n\u003cp\u003eInspect the fragment-retention area and remove any retained metal fragments according to the applicable manufacturer instructions.\u003c\/p\u003e\n\n\u003cp\u003eThe reference instrument features a head that can be disassembled for cleaning. Follow the manufacturer's prescribed disassembly, cleaning, inspection, and reassembly procedures.\u003c\/p\u003e\n\n\u003cp\u003eClean and sterilize the instrument according to the applicable product-specific instructions and the veterinary facility's validated reprocessing procedures.\u003c\/p\u003e\n\n\u003cp\u003eThe retracted 340 mm configuration is designed to fit many autoclaves, but actual chamber clearance and validated cycle compatibility must be confirmed for the specific equipment.\u003c\/p\u003e\n\n\u003cp\u003eDo not assume particular sterilization temperatures, exposure times, processing pressures, or cleaning-agent compatibility without verified product instructions.\u003c\/p\u003e\n\n\u003ch2\u003eOrdering the Safety Implant Cutter\u003c\/h2\u003e\n\n\u003cp\u003ePeak Surgicals supplies orthopedic and veterinary surgical instruments for animal hospitals, veterinary orthopedic departments, surgical clinics, distributors, and medical procurement professionals.\u003c\/p\u003e\n\n\u003cp\u003eWhen selecting this instrument, specify the \u003cstrong\u003eSafety Implant Cutter with 4 mm maximum cutting capacity, telescopic 340–470 mm handles, and retained-fragment cutting head\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eExplore related \u003ca href=\"\/nl\/collections\/orthopedic-instruments\"\u003eOrthopedic Instruments\u003c\/a\u003e and \u003ca href=\"\/nl\/collections\/veterinary-surgical-instruments\"\u003eVeterinary Surgical Instruments\u003c\/a\u003e for additional pin cutters, wire cutters, and instruments used in fracture fixation procedures.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003e1. What is the Safety Implant Cutter used for?\u003c\/h3\u003e\n\u003cp\u003eIt is designed for cutting compatible orthopedic fixation pins and implants, particularly during veterinary external skeletal fixation procedures.\u003c\/p\u003e\n\n\u003ch3\u003e2. What is its maximum cutting capacity?\u003c\/h3\u003e\n\u003cp\u003eThe reference instrument has a maximum specified cutting capacity of 4.0 mm.\u003c\/p\u003e\n\n\u003ch3\u003e3. How does the safety cutting head work?\u003c\/h3\u003e\n\u003cp\u003eThe cutting head is designed to temporarily retain the separated pin end rather than allowing it to fly away during cutting.\u003c\/p\u003e\n\n\u003ch3\u003e4. What are the instrument lengths?\u003c\/h3\u003e\n\u003cp\u003eThe telescopic handles allow the overall length to change between 340 mm when retracted and 470 mm when extended.\u003c\/p\u003e\n\n\u003ch3\u003e5. How close to the cutting head does the instrument cut?\u003c\/h3\u003e\n\u003cp\u003eThe reference catalog specifies a cutting position approximately 5 mm below the face of the cutter.\u003c\/p\u003e\n\n\u003ch3\u003e6. Can the cutting head be cleaned separately?\u003c\/h3\u003e\n\u003cp\u003eThe reference cutter features a disassemblable head for cleaning. Follow the manufacturer's product-specific instructions for disassembly and reprocessing.\u003c\/p\u003e\n\n\u003ch3\u003e7. Is this a reusable instrument?\u003c\/h3\u003e\n\u003cp\u003eYes. The reference instrument is described as reusable stainless steel, subject to appropriate cleaning, inspection, maintenance, and validated reprocessing.\u003c\/p\u003e\n","brand":"PEAK SURGICALS","offers":[{"title":"Default Title","offer_id":57628210200740,"sku":"PS-J-192","price":328.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/files\/2_04e7cd93-327d-4eaa-a3d0-034cf6cca24a.jpg?v=1795514891","url":"https:\/\/peaksurgicals.com\/nl\/products\/safety-implant-cutter-4mm-capacity-telescopic-handles","provider":"PEAK SURGICALS","version":"1.0","type":"link"}