{"product_id":"kelly-proctoscope-22-mm-x-140-mm-detachable-obturator-for-proctoscopy","title":"Kelly Proctoscope 22 mm x 140 mm – Detachable Obturator for Proctoscopy","description":"\u003cp\u003eKelly Proctoscope 22 mm x 140 mm with Detachable Obturator, SKU PI-004, is a reusable manual proctology instrument manufactured from German stainless steel for direct examination of the anal canal and distal rectum. The 22 mm tubular body provides a fixed viewing corridor, while the 140 mm working length extends beyond a short anoscope for inspection of lower rectal mucosa. Its removable obturator occupies the lumen during insertion and presents a smooth rounded distal profile, reducing mucosal entry into the open tube as the instrument passes through the anal canal. After positioning, the obturator is withdrawn to expose the bore for direct visualization, swabbing, suction access, biopsy-forceps passage, or delivery of locally applied treatment when indicated. The lateral operating handle gives the surgeon control during advancement, rotation, stabilization, and staged withdrawal. Colorectal surgeons, general surgeons, proctologists, and gastrointestinal procedure teams use this pattern for proctoscopy, internal hemorrhoid assessment, rectal bleeding evaluation, anal fissure inspection, fistula opening localization, distal rectal lesion examination, targeted biopsy access, and postoperative review after hemorrhoidectomy, fistulotomy, fissure surgery, or local anorectal excision. The instrument is suited to operating theatres, colorectal clinics, ambulatory procedure units, and hospital examination rooms.\u003c\/p\u003e\n\n\u003ch2\u003eRigid Tubular Geometry and Detachable Obturator Mechanism\u003c\/h2\u003e\n\u003cp\u003eThe Kelly pattern uses a rigid cylindrical tube rather than expanding blades, producing a constant 22 mm access channel through the anal canal. During introduction, the obturator is seated completely within the scope so its rounded nose projects at the distal end and converts the open tubular edge into a smooth leading profile. This arrangement limits soft-tissue prolapse into the lumen while the surgeon advances the assembly with controlled pressure. Once the desired depth is reached, the obturator is removed, leaving an unobstructed pathway for direct inspection and accessory passage. The proximal flange helps define the external entrance and serves as a positional reference while the operator maintains the tube within the canal. A flat lateral handle remains outside the visual axis, allowing rotation of the barrel during circumferential examination without placing the hand over the viewing opening. Because there is no ratchet, screw spreader, or blade-expansion mechanism, exposure is determined by the fixed diameter of the tube. The polished internal bore supports light transmission from an external examination source and provides a straight route for swabs, suction tips, biopsy forceps, or other slender instruments used under direct vision. The detachable configuration also permits separation of the obturator and scope body for cleaning and inspection.\u003c\/p\u003e\n\n\u003ch2\u003eProctoscopy Workflow and Distal Rectal Assessment\u003c\/h2\u003e\n\u003cp\u003eFor routine proctoscopy, the assembled scope and obturator are lubricated and introduced through the anal canal with the rounded tip leading. After the 140 mm tube is positioned, the insert is withdrawn and the clinician inspects the dentate-line region, hemorrhoidal cushions, anal canal, and accessible distal rectal mucosa while gradually rotating and retracting the barrel. In internal hemorrhoid assessment, this sequence permits identification of prolapse, congestion, friability, ulceration, thrombosed tissue, and active or recent bleeding. During evaluation of hematochezia or localized rectal bleeding, the fixed lumen helps isolate distal mucosal lesions, traumatic injury, postoperative bleeding points, or inflamed tissue for closer inspection. In suspected fistula-in-ano, direct visualization may assist localization of an internal opening before probing, imaging correlation, or operative treatment. The channel can also accommodate a slender biopsy forceps for sampling a visible lower rectal abnormality, or a suction tip when blood or mucus obscures the field. Following hemorrhoidectomy, fistulotomy, fissurectomy, or local anorectal excision, the same instrument can be used during follow-up to assess healing surfaces, residual bleeding, scar formation, stenotic change, or recurrent mucosal pathology. Its 140 mm reach makes it suitable when examination must extend beyond the immediate anal canal.\u003c\/p\u003e\n\n\u003ch2\u003e22 mm Diameter, 140 mm Length and Component Selection\u003c\/h2\u003e\n\u003cp\u003eThe 22 mm x 140 mm configuration is intended for adult anorectal examination when the clinician requires a stable tubular field and more distal-rectal reach than a short anoscope. The 22 mm diameter maintains enough working space for direct viewing, cotton swab passage, limited suction, and compatible slender biopsy instrumentation without using a bivalve spreading mechanism. The 140 mm length provides access from the anal verge into the lower rectum, supporting assessment of hemorrhoidal disease, bleeding sources, mucosal irregularities, postoperative sites, and visible distal lesions. The scope body is the principal access component: its rigid cylindrical wall keeps the examination corridor open and guides accessories along a predictable path. The obturator is the insertion component and is used only while advancing the assembly; its rounded terminal profile protects the tube opening from directly contacting and scooping mucosa. After removal, the full bore becomes available for inspection. The lateral handle supplies rotational leverage and permits controlled withdrawal during a systematic circumferential survey. The proximal flange provides an external reference and helps prevent unintended advancement while keeping the entry aperture accessible. Together, these components support a manual workflow in which insertion, visualization, tissue assessment, accessory passage, and withdrawal can be performed without an integrated light source or expanding jaw system.\u003c\/p\u003e\n\n\u003ch2\u003eGerman Stainless Steel, Reprocessing and Procurement Standards\u003c\/h2\u003e\n\u003cp\u003eGerman stainless steel provides the structural rigidity required for a reusable 22 mm proctoscope while resisting corrosion during repeated cleaning, disinfection, and steam-sterilization cycles. The mirror-polished finish creates smooth patient-contact and internal surfaces, reducing drag during insertion and facilitating removal of blood, mucus, lubricant, and tissue residue during decontamination. Reprocessing begins promptly after use by separating the obturator from the tubular body, removing visible soil, brushing and flushing the bore, rinsing thoroughly, and drying each component before inspection. Staff should examine the distal rim, internal channel, flange, handle junction, obturator alignment, and mating surfaces for retained debris, deformation, corrosion, or mechanical damage before packaging. The stainless-steel components can then be processed in a validated hospital autoclave cycle appropriate for reusable surgical instrumentation. CE marking supports applicable conformity documentation for regulated medical-device markets, while ISO 13485 identifies the quality-management framework governing controlled manufacture, traceability, and documentation. For United States purchasing, FDA-compliant procurement requires the relevant establishment, device, labeling, import, and supplier records applicable to the transaction. Peak Surgicals supports institutional and distributor purchasing with a one-year warranty, single-piece MOQ, OEM and private-label ordering, and after-sale return or replacement service.\u003c\/p\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003ctd\u003ePI-004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eKelly Proctoscope 22 mm x 140 mm with Detachable Obturator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e$41.00 USD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSize\/Gauge Variants\u003c\/th\u003e\n\u003ctd\u003e22 mm diameter x 140 mm length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstrument Category\u003c\/th\u003e\n\u003ctd\u003eProctology Instruments \/ Proctoscopes and Anoscopes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcedure\u003c\/th\u003e\n\u003ctd\u003eProctoscopy, anoscopy, hemorrhoid assessment, distal rectal examination, anal fissure inspection, fistula evaluation, biopsy access and postoperative anorectal review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eGerman stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eMirror-polished finish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSterilization\u003c\/th\u003e\n\u003ctd\u003eReusable and compatible with validated steam-autoclave processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstrument Classification\u003c\/th\u003e\n\u003ctd\u003eReusable manual proctology examination instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReusable\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE marked, ISO 13485 quality system, FDA-compliant procurement documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMOQ\u003c\/th\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOEM \/ Custom Orders\u003c\/th\u003e\n\u003ctd\u003eAvailable for hospitals, distributors and private-label requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAfter-Sale Service\u003c\/th\u003e\n\u003ctd\u003eReturn and replacement support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow does the Kelly Proctoscope differ from a Pratt Rectal Speculum?\u003c\/strong\u003e\u003cbr\u003eKelly Proctoscope 22 mm x 140 mm with Detachable Obturator creates exposure through a fixed cylindrical lumen rather than adjustable spreading blades. A Pratt Rectal Speculum uses paired blades that are inserted in a closed position and opened laterally after placement. The Kelly configuration uses an obturator to close the distal tube during introduction and then removes it for inspection. Its fixed bore is suited to circumferential mucosal examination and passage of slender accessories through a stable corridor. The Pratt pattern is more appropriate when the operative objective requires adjustable lateral exposure of the anal canal. Instrument selection therefore depends on whether tubular proctoscopy or blade-mediated spreading is required.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhy is the 22 mm x 140 mm size selected for proctoscopy?\u003c\/strong\u003e\u003cbr\u003eKelly Proctoscope 22 mm x 140 mm with Detachable Obturator is selected when the clinician needs both a stable adult-caliber viewing channel and access into the lower rectum. The 22 mm diameter provides sufficient room for visual assessment, swabbing, limited suction, and compatible biopsy instruments. Its 140 mm length extends farther than shorter anoscopes used primarily for the immediate anal canal. During hemorrhoid evaluation, the surgeon can inspect the dentate line and internal hemorrhoidal cushions before advancing toward accessible distal rectal mucosa. For localized bleeding or lesion assessment, the added reach permits inspection beyond the anal verge while maintaining rigid control. This configuration is therefore suited to routine adult proctoscopy and lower rectal examination.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat do CE, ISO 13485 and FDA procurement standards mean for this instrument?\u003c\/strong\u003e\u003cbr\u003eKelly Proctoscope 22 mm x 140 mm with Detachable Obturator is supplied within Peak Surgicals' CE and ISO 13485 procurement framework. CE marking supports applicable conformity documentation for regulated medical-device markets. ISO 13485 identifies the quality-management system governing controlled manufacturing, traceability, documentation, and supplier processes. FDA procurement context for United States buyers involves the relevant establishment, device, labeling, import, and distribution documentation. Hospitals and distributors should retain these records within vendor qualification and purchasing files. These regulatory frameworks address different aspects of compliance and should be managed accordingly during institutional procurement.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow are the detachable obturator and lateral handle used during insertion?\u003c\/strong\u003e\u003cbr\u003eThe obturator is fully seated within the scope before introduction so its rounded end covers the open distal tube. This creates a smooth insertion profile as the assembly passes through the anal canal. Once the required depth is reached, the clinician removes the insert to expose the viewing lumen. The lateral handle then provides leverage for stabilization, controlled rotation, directional adjustment, and staged withdrawal. The proximal flange remains outside the canal as a positional reference while the internal surface is inspected. Kelly Proctoscope 22 mm x 140 mm with Detachable Obturator therefore relies on manual obturator placement and handle control rather than a ratchet, pivot, or blade-expansion mechanism.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow should hospitals sterilize and manage this reusable proctoscope?\u003c\/strong\u003e\u003cbr\u003eHospital sterile-processing teams should separate the obturator from the scope body immediately after the procedure according to their validated workflow. Visible blood, mucus, lubricant, and tissue residue should be removed before brushing and flushing the internal bore. Each component is then rinsed, dried, and inspected for retained debris, deformation, surface damage, or corrosion. The instrument can be packaged and processed through a validated steam-autoclave cycle suitable for reusable stainless-steel surgical devices. Kelly Proctoscope 22 mm x 140 mm with Detachable Obturator should also be checked for proper component fit before being returned to clinical inventory. Procurement teams should retain SKU, warranty, regulatory, supplier, and reordering records for traceable inventory management.\u003c\/p\u003e","brand":"PEAK SURGICALS","offers":[{"title":"22 mm x 140 mm","offer_id":51428684791972,"sku":"PI-004","price":40.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/files\/Kelly_Proctoscope_22_mm_x_140_mm_Detachable_Obturator_for_Proctoscopy.jpg?v=1786103715","url":"https:\/\/peaksurgicals.com\/it\/products\/kelly-proctoscope-22-mm-x-140-mm-detachable-obturator-for-proctoscopy","provider":"PEAK SURGICALS","version":"1.0","type":"link"}