{"product_id":"pointed-reduction-forceps-with-spinlock","title":"Pointed Reduction Forceps with Spinlock","description":"\n\u003ch2\u003ePointed Reduction Forceps with Spinlock – 135mm \u0026amp; 180mm\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003ePointed Reduction Forceps with Spinlock\u003c\/strong\u003e are specialized orthopedic surgical instruments designed for the reduction, alignment, and temporary stabilization of bone fragments during fracture repair and osteotomy procedures. Featuring curved pointed jaws, double finger-ring handles, and an adjustable spinlock mechanism, these forceps support controlled fragment positioning during veterinary orthopedic surgery.\u003c\/p\u003e\n\n\u003cp\u003eAvailable in \u003cstrong\u003e135 mm and 180 mm lengths\u003c\/strong\u003e, the instrument range includes Standard, Small Fragment, and Large Fragment configurations. The flip-over spinlock allows the surgeon to manipulate fragments manually before maintaining the selected jaw position.\u003c\/p\u003e\n\n\u003ch2\u003eInstrument Design and Features\u003c\/h2\u003e\n\n\u003ch3\u003eCurved Pointed Reduction Jaws\u003c\/h3\u003e\n\n\u003cp\u003eThe forceps feature opposing curved pointed jaws designed to engage selected bone fragments during orthopedic reduction procedures.\u003c\/p\u003e\n\n\u003cp\u003eThe pointed working ends provide a focused contact profile for positioning and temporarily holding fragments during surgical fixation.\u003c\/p\u003e\n\n\u003cp\u003eJaw placement and applied pressure must be determined according to the bone anatomy, fracture characteristics, and selected surgical technique.\u003c\/p\u003e\n\n\u003ch3\u003eAdjustable Flip-Over Spinlock\u003c\/h3\u003e\n\n\u003cp\u003eThe defining feature of these orthopedic reduction forceps is the \u003cstrong\u003eadjustable spinlock mechanism\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe spinlock can be moved away from the operating position during initial fragment manipulation, allowing the surgeon to control the forceps directly.\u003c\/p\u003e\n\n\u003cp\u003eOnce the desired reduction is achieved, the spinlock can be moved into position and gently tightened to maintain the selected jaw closure.\u003c\/p\u003e\n\n\u003cp\u003eThe mechanism is designed for temporary fragment stabilization during subsequent surgical steps. It does not replace definitive fracture fixation.\u003c\/p\u003e\n\n\u003ch3\u003eDouble Ring Handles\u003c\/h3\u003e\n\n\u003cp\u003eThe forceps incorporate two circular finger rings connected to elongated arms. This configuration provides manual control during opening, closing, and positioning of the working jaws.\u003c\/p\u003e\n\n\u003cp\u003eThe ring-handled design allows initial fragment manipulation before the spinlock is engaged.\u003c\/p\u003e\n\n\u003ch3\u003eThree Instrument Configurations\u003c\/h3\u003e\n\n\u003cp\u003eThe product family includes three distinct catalog configurations:\u003c\/p\u003e\n\n\u003ch4\u003eStandard Pointed Reduction Forceps – 180mm\u003c\/h4\u003e\n\u003cp\u003eReference 001200SL identifies the standard 180 mm configuration with pointed jaws and spinlock closure.\u003c\/p\u003e\n\n\u003ch4\u003eSmall Fragment Forceps with Spinlock – 135mm\u003c\/h4\u003e\n\u003cp\u003eReference 001201SL identifies the shorter 135 mm configuration intended for delicate reduction of smaller bone fragments.\u003c\/p\u003e\n\n\u003ch4\u003eLarge Fragment Forceps with Spinlock – 180mm\u003c\/h4\u003e\n\u003cp\u003eReference 001245SL identifies the large-fragment 180 mm configuration. Although it shares the same nominal length as the standard model, it is a separate catalog variant.\u003c\/p\u003e\n\n\u003ch2\u003eClinical Applications in Veterinary Orthopedic Surgery\u003c\/h2\u003e\n\n\u003ch3\u003eFracture Reduction\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003ePointed Reduction Forceps with Spinlock\u003c\/strong\u003e are designed to temporarily hold selected bone fragments in alignment during orthopedic fracture repair.\u003c\/p\u003e\n\n\u003cp\u003eThe surgeon may use the instrument to position fragments before applying the selected definitive fixation method.\u003c\/p\u003e\n\n\u003cp\u003eThese forceps are associated with surgical reduction techniques involving long bones, small bone fragments, and selected periarticular fractures.\u003c\/p\u003e\n\n\u003ch3\u003eTemporary Fragment Stabilization\u003c\/h3\u003e\n\n\u003cp\u003eAfter achieving the intended fragment alignment, the spinlock can be engaged to maintain temporary compression or positioning.\u003c\/p\u003e\n\n\u003cp\u003eThis function may be useful during selected stages of implant positioning and fracture fixation, subject to the surgeon's operative plan.\u003c\/p\u003e\n\n\u003ch3\u003eOsteotomy Procedures\u003c\/h3\u003e\n\n\u003cp\u003ePointed reduction forceps may also be used to hold selected bone segments during planned osteotomy procedures.\u003c\/p\u003e\n\n\u003cp\u003eThe suitability of the Standard, Small Fragment, or Large Fragment configuration depends on the surgical site, fragment dimensions, available access, and surgeon preference.\u003c\/p\u003e\n\n\u003ch2\u003eSpinlock vs. Conventional Ratchet Reduction Forceps\u003c\/h2\u003e\n\n\u003cp\u003eConventional ratchet forceps generally maintain closure through a series of fixed locking positions.\u003c\/p\u003e\n\n\u003cp\u003eSpinlock reduction forceps incorporate an adjustable locking mechanism that can be disengaged during initial positioning and engaged after the intended reduction has been achieved.\u003c\/p\u003e\n\n\u003cp\u003eThis configuration provides an alternative to conventional ratchet locking when the surgeon requires direct control of the jaws during fragment manipulation.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n      \u003ctd\u003ePointed Reduction Forceps with Spinlock\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eInstrument Type\u003c\/th\u003e\n      \u003ctd\u003eOrthopedic Bone Reduction Forceps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eAvailable Lengths\u003c\/th\u003e\n      \u003ctd\u003e135 mm and 180 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eWorking End\u003c\/th\u003e\n      \u003ctd\u003eOpposing Curved Pointed Jaws\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eLocking Mechanism\u003c\/th\u003e\n      \u003ctd\u003eAdjustable Flip-Over Spinlock\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eHandle Design\u003c\/th\u003e\n      \u003ctd\u003eDouble Ring Handles\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eStandard Variant\u003c\/th\u003e\n      \u003ctd\u003e180 mm – Reference 001200SL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eSmall Fragment Variant\u003c\/th\u003e\n      \u003ctd\u003e135 mm – Reference 001201SL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eLarge Fragment Variant\u003c\/th\u003e\n      \u003ctd\u003e180 mm – Reference 001245SL\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003ePrimary Specialty\u003c\/th\u003e\n      \u003ctd\u003eVeterinary Orthopedic Surgery\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003ePrimary Application\u003c\/th\u003e\n      \u003ctd\u003eBone Fragment Reduction and Temporary Stabilization\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eUnit of Measure\u003c\/th\u003e\n      \u003ctd\u003eEach\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstrument Inspection and Handling\u003c\/h2\u003e\n\n\u003cp\u003eBefore clinical use, inspect the pointed jaws for visible wear, deformation, or damage. Examine the finger rings, pivot joint, spinlock screw, and associated locking components.\u003c\/p\u003e\n\n\u003cp\u003eConfirm that the forceps open and close smoothly and that the spinlock engages and releases according to the manufacturer's instructions.\u003c\/p\u003e\n\n\u003cp\u003eClean and process the instrument according to the applicable product-specific reprocessing instructions and the veterinary facility's validated procedures.\u003c\/p\u003e\n\n\u003cp\u003ePay particular attention to the spinlock threads, joint assembly, and pointed jaws during inspection and cleaning.\u003c\/p\u003e\n\n\u003cp\u003eDo not assume specific sterilization temperatures, exposure times, or cleaning-agent compatibility without verified manufacturer documentation.\u003c\/p\u003e\n\n\u003ch2\u003eOrder Pointed Reduction Forceps from Peak Surgicals\u003c\/h2\u003e\n\n\u003cp\u003ePeak Surgicals supplies orthopedic surgical instruments to veterinary clinics, animal hospitals, orthopedic surgical centers, distributors, and medical procurement professionals.\u003c\/p\u003e\n\n\u003cp\u003eSelect the required \u003cstrong\u003eStandard 180 mm, Small Fragment 135 mm, or Large Fragment 180 mm\u003c\/strong\u003e configuration when ordering.\u003c\/p\u003e\n\n\u003cp\u003eExplore related \u003ca href=\"\/es\/collections\/orthopedic-instruments-general-orthopedic-instruments-bone-holding-forceps\"\u003eBone Holding Forceps\u003c\/a\u003e and \u003ca href=\"\/es\/collections\/orthopedic-instruments\"\u003eOrthopedic Instruments\u003c\/a\u003e for additional bone reduction and fracture fixation instruments.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003e1. What are Pointed Reduction Forceps with Spinlock used for?\u003c\/h3\u003e\n\u003cp\u003eThey are designed to align and temporarily stabilize bone fragments during selected orthopedic fracture repair and osteotomy procedures.\u003c\/p\u003e\n\n\u003ch3\u003e2. What sizes are available?\u003c\/h3\u003e\n\u003cp\u003eThe documented range includes Standard 180 mm, Small Fragment 135 mm, and Large Fragment 180 mm configurations.\u003c\/p\u003e\n\n\u003ch3\u003e3. How does the spinlock mechanism work?\u003c\/h3\u003e\n\u003cp\u003eThe spinlock can be disengaged during initial fragment reduction, then moved into position and gently tightened to maintain the selected jaw closure.\u003c\/p\u003e\n\n\u003ch3\u003e4. What is the difference between Standard and Large Fragment configurations?\u003c\/h3\u003e\n\u003cp\u003eThey are separate catalog configurations, both measuring 180 mm. Exact jaw dimensions and opening capacities should be confirmed from the manufacturer's specifications.\u003c\/p\u003e\n\n\u003ch3\u003e5. Do these forceps provide permanent fracture fixation?\u003c\/h3\u003e\n\u003cp\u003eNo. They are intended for temporary bone fragment positioning and stabilization during appropriate surgical procedures.\u003c\/p\u003e\n\n\u003ch3\u003e6. What are the catalog reference numbers?\u003c\/h3\u003e\n\u003cp\u003eThe documented references are 001200SL for Standard 180 mm, 001201SL for Small Fragment 135 mm, and 001245SL for Large Fragment 180 mm.\u003c\/p\u003e\n","brand":"PEAK SURGICALS","offers":[{"title":"Standard Pointed Reduction\t180 mm","offer_id":57628187164836,"sku":"PS-J-185","price":49.49,"currency_code":"USD","in_stock":true},{"title":"Small Fragment\t135 mm","offer_id":57628187197604,"sku":"PS-J-186","price":49.49,"currency_code":"USD","in_stock":true},{"title":"Large Fragment\t180 mm","offer_id":57628187230372,"sku":"PS-J-187","price":49.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/files\/1_1edf2cb7-15c1-4ea7-a6cb-bd4c19adfb62.jpg?v=1795509239","url":"https:\/\/peaksurgicals.com\/es\/products\/pointed-reduction-forceps-with-spinlock","provider":"PEAK SURGICALS","version":"1.0","type":"link"}