{"product_id":"endoscopic-rigid-facelift-needle-holder","title":"Endoscopic Rigid Facelift Needle Holder","description":"\n\u003ch2\u003eEndoscopic Rigid Facelift Needle Holder – 18.5cm, 5mm\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eEndoscopic Rigid Facelift Needle Holder\u003c\/strong\u003e is a specialized surgical instrument designed for needle handling and deep suturing during endoscopic facial plastic surgery. Featuring a 5 mm needle-holding working end, locking latch, straight shaft, and in-line ergonomic handle, this instrument provides a dedicated configuration for surgical needle placement and facial fascia fixation.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument features a \u003cstrong\u003e7⅛-inch (18.5 cm) shaft\u003c\/strong\u003e, providing a longer working profile than the related 15 cm endoscopic needle holder. Its robust 5 mm working end is designed to hold surgical needles specified up to 3-0 in the reference manufacturer's product description.\u003c\/p\u003e\n\n\u003ch2\u003eInstrument Design and Features\u003c\/h2\u003e\n\n\u003ch3\u003eRobust 5mm Needle-Holding Working End\u003c\/h3\u003e\n\n\u003cp\u003eThe Endoscopic Rigid Facelift Needle Holder incorporates a \u003cstrong\u003e5 mm diameter working end\u003c\/strong\u003e with opposing jaws designed to grasp and manipulate surgical suture needles.\u003c\/p\u003e\n\n\u003cp\u003eThe needle-holding mechanism provides a specialized working configuration for suturing during selected endoscopic facial surgical techniques.\u003c\/p\u003e\n\n\u003cp\u003eThe reference manufacturer describes the instrument as suitable for holding needles up to a 3-0 suture configuration. Actual compatibility depends on the needle dimensions, curvature, and characteristics of the selected surgical needle.\u003c\/p\u003e\n\n\u003cp\u003eThe working jaws should be positioned according to the surgeon's intended suturing technique, and excessive closing force should be avoided.\u003c\/p\u003e\n\n\u003ch3\u003eLocking Latch Mechanism\u003c\/h3\u003e\n\n\u003cp\u003eThe needle holder features an integrated locking latch designed to maintain the selected jaw closure during needle handling.\u003c\/p\u003e\n\n\u003cp\u003eThe locking mechanism allows the jaws to remain engaged while the surgeon manipulates the instrument during the relevant suturing stage.\u003c\/p\u003e\n\n\u003cp\u003eThis feature distinguishes the instrument from conventional non-locking endoscopic tissue graspers.\u003c\/p\u003e\n\n\u003cp\u003eThe latch should be inspected before each procedure to verify appropriate engagement, release, and mechanical movement.\u003c\/p\u003e\n\n\u003ch3\u003e18.5cm Straight Shaft\u003c\/h3\u003e\n\n\u003cp\u003eThe instrument has an \u003cstrong\u003e18.5 cm straight shaft\u003c\/strong\u003e intended for deeper needle placement during selected endoscopic facial procedures.\u003c\/p\u003e\n\n\u003cp\u003eThe longer shaft provides an alternative working length compared with the shorter 15 cm Endoscopic Facelift Needle Holder.\u003c\/p\u003e\n\n\u003cp\u003eThe straight configuration is relevant to surgical approaches where the surgeon requires an elongated instrument profile for needle manipulation.\u003c\/p\u003e\n\n\u003cp\u003eInstrument reach, needle orientation, and surgical access depend on the operative approach and anatomical requirements.\u003c\/p\u003e\n\n\u003ch3\u003eInsulated Shaft Construction\u003c\/h3\u003e\n\n\u003cp\u003eThe reference instrument family incorporates insulated shafts as part of its endoscopic design.\u003c\/p\u003e\n\n\u003cp\u003eThe insulated section should be examined for cracks, visible wear, surface defects, and separation from the underlying shaft before clinical use.\u003c\/p\u003e\n\n\u003cp\u003eShaft insulation does not independently establish compatibility with electrosurgical generators, monopolar equipment, or other powered surgical systems.\u003c\/p\u003e\n\n\u003ch3\u003eIn-Line Ergonomic Handle\u003c\/h3\u003e\n\n\u003cp\u003eThe instrument features an in-line ergonomic handle with opposing perforated control arms.\u003c\/p\u003e\n\n\u003cp\u003eThe handle is designed for thumb-and-index-finger manipulation, allowing the surgeon to operate the needle-holding jaws through movement of the control arms.\u003c\/p\u003e\n\n\u003cp\u003eIts configuration differs from conventional ring-handled needle holders used in open surgical procedures.\u003c\/p\u003e\n\n\u003cp\u003eThe ergonomic handle is intended to provide tactile feedback and accommodate different hand positions during instrument handling.\u003c\/p\u003e\n\n\u003ch3\u003eFlush-Port Assembly\u003c\/h3\u003e\n\n\u003cp\u003eA circular flush-port opening is visible near the junction between the shaft and the handle.\u003c\/p\u003e\n\n\u003cp\u003eThis feature forms part of the instrument assembly and should be inspected during preparation and reprocessing.\u003c\/p\u003e\n\n\u003cp\u003eCleaning and flushing must follow the applicable manufacturer's product-specific instructions. No flushing pressure, cleaning solution, or connector dimensions are specified without verified documentation.\u003c\/p\u003e\n\n\u003ch2\u003eClinical Applications in Endoscopic Facial Surgery\u003c\/h2\u003e\n\n\u003ch3\u003eDeep Needle Placement\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eEndoscopic Rigid Facelift Needle Holder\u003c\/strong\u003e is intended for surgical needle handling where a longer shaft is required for access to deeper operative areas.\u003c\/p\u003e\n\n\u003cp\u003eDuring selected endoscopic facial procedures, the surgeon may use the needle holder to grasp and guide the surgical needle through the intended tissue structures.\u003c\/p\u003e\n\n\u003cp\u003eThe 5 mm working-end configuration and locking latch provide a specialized arrangement for maintaining engagement with the selected needle.\u003c\/p\u003e\n\n\u003ch3\u003eFacial Fascia Suturing\u003c\/h3\u003e\n\n\u003cp\u003eEndoscopic facial surgery may involve suturing and fixation of selected fascial structures as part of the operative plan.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument provides a needle-holding configuration for these applications when the surgeon requires an elongated straight shaft and locking jaws.\u003c\/p\u003e\n\n\u003cp\u003eNeedle selection, suture type, fixation location, and suturing technique remain dependent on the surgical procedure and surgeon's assessment.\u003c\/p\u003e\n\n\u003ch3\u003eEndoscopic Facelift Procedures\u003c\/h3\u003e\n\n\u003cp\u003eThe Endoscopic Rigid Facelift Needle Holder is relevant to selected endoscopic facelift and facial suspension procedures.\u003c\/p\u003e\n\n\u003cp\u003eIt may be included in an endoscopic instrument setup alongside appropriate dissectors, graspers, scissors, elevators, and visualization equipment.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument is intended for use by appropriately trained surgical professionals.\u003c\/p\u003e\n\n\u003ch2\u003eRigid 5mm vs. Delicate 3mm Endoscopic Needle Holder\u003c\/h2\u003e\n\n\u003cp\u003eThe rigid-style 5 mm Endoscopic Needle Holder and the related 3 mm Endoscopic Facelift Needle Holder are distinct instrument configurations.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e5 mm model\u003c\/strong\u003e has an 18.5 cm shaft and a robust needle-holding working end with locking latch. It is intended for deeper needle placement during selected endoscopic procedures.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e3 mm model\u003c\/strong\u003e has a 15 cm shaft and a more delicate working-end configuration associated with selected facial suturing applications.\u003c\/p\u003e\n\n\u003cp\u003eBoth instruments should be selected according to the required working length, needle characteristics, and intended surgical technique.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n      \u003ctd\u003eEndoscopic Rigid Facelift Needle Holder\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eReference Pattern\u003c\/th\u003e\n      \u003ctd\u003eEndoscopic Fascia Needle Holder\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eCatalog Reference\u003c\/th\u003e\n      \u003ctd\u003eB 65102\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eInstrument Type\u003c\/th\u003e\n      \u003ctd\u003eEndoscopic Suturing Needle Holder\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eShaft Length\u003c\/th\u003e\n      \u003ctd\u003e7⅛ inches \/ 18.5 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eWorking-End Diameter\u003c\/th\u003e\n      \u003ctd\u003e5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eShaft Configuration\u003c\/th\u003e\n      \u003ctd\u003eStraight\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eShaft Insulation\u003c\/th\u003e\n      \u003ctd\u003eInsulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eWorking End\u003c\/th\u003e\n      \u003ctd\u003eOpposing Needle-Holding Jaws\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eLocking Mechanism\u003c\/th\u003e\n      \u003ctd\u003eLocking Latch\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eNeedle Capacity\u003c\/th\u003e\n      \u003ctd\u003eUp to 3-0, per reference catalog\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eHandle Design\u003c\/th\u003e\n      \u003ctd\u003eIn-Line Ergonomic Handle\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eHandle Operation\u003c\/th\u003e\n      \u003ctd\u003eThumb and Index Finger Control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eAdditional Feature\u003c\/th\u003e\n      \u003ctd\u003eFlush Port\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003ePrimary Specialty\u003c\/th\u003e\n      \u003ctd\u003eEndoscopic Plastic and Facial Surgery\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eClinical Application\u003c\/th\u003e\n      \u003ctd\u003eDeep Needle Placement and Facial Fascia Suturing\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstrument Inspection and Handling\u003c\/h2\u003e\n\n\u003cp\u003eBefore use, inspect the needle-holding jaws for visible wear, misalignment, or damage.\u003c\/p\u003e\n\n\u003cp\u003eCheck the locking latch for appropriate engagement and release. Examine the ergonomic handle and control mechanism for normal mechanical movement.\u003c\/p\u003e\n\n\u003cp\u003eInspect the straight shaft, insulation, and flush-port assembly for visible surface defects or damage.\u003c\/p\u003e\n\n\u003cp\u003eClean and process the instrument according to the applicable manufacturer's instructions and the healthcare facility's validated instrument-reprocessing procedures.\u003c\/p\u003e\n\n\u003cp\u003eParticular attention should be given to the needle-holding jaws, locking components, shaft insulation, handle mechanism, and flush-port area during cleaning and inspection.\u003c\/p\u003e\n\n\u003cp\u003eDo not assume specific sterilization temperatures, exposure times, flushing pressures, or cleaning-agent compatibility without verified product-specific instructions.\u003c\/p\u003e\n\n\u003cp\u003eProtect the working jaws and handle assembly from mechanical damage during storage and transportation.\u003c\/p\u003e\n\n\u003ch2\u003eOrdering the Endoscopic Rigid Facelift Needle Holder\u003c\/h2\u003e\n\n\u003cp\u003ePeak Surgicals supplies specialized surgical instruments to hospitals, facial plastic surgery practices, aesthetic surgery clinics, reconstructive surgery departments, distributors, and medical procurement professionals.\u003c\/p\u003e\n\n\u003cp\u003eWhen ordering, specify the \u003cstrong\u003eEndoscopic Rigid Facelift Needle Holder with 18.5 cm straight shaft, 5 mm working end, and locking latch\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe corresponding reference model is B 65102. Confirm the required instrument dimensions and inventory reference before purchase.\u003c\/p\u003e\n\n\u003cp\u003eExplore related \u003ca href=\"\/de\/collections\/plastic-surgery-instruments-endoscopic-face-and-forehead-lift\"\u003eEndoscopic Face and Forehead Lift Instruments\u003c\/a\u003e for additional needle holders, graspers, dissectors, scissors, and specialized endoscopic surgical instruments.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003e1. What is the Endoscopic Rigid Facelift Needle Holder used for?\u003c\/h3\u003e\n\u003cp\u003eIt is designed for needle handling and deep suturing during selected endoscopic facelift and facial fascia fixation procedures.\u003c\/p\u003e\n\n\u003ch3\u003e2. What is the shaft length?\u003c\/h3\u003e\n\u003cp\u003eThe specified shaft length is 7⅛ inches (18.5 cm).\u003c\/p\u003e\n\n\u003ch3\u003e3. What is the working-end diameter?\u003c\/h3\u003e\n\u003cp\u003eThe instrument has a 5 mm needle-holding working end.\u003c\/p\u003e\n\n\u003ch3\u003e4. Does the needle holder have a locking mechanism?\u003c\/h3\u003e\n\u003cp\u003eYes. It features a locking latch designed to maintain selected jaw closure during needle manipulation.\u003c\/p\u003e\n\n\u003ch3\u003e5. What needle size can the instrument hold?\u003c\/h3\u003e\n\u003cp\u003eThe reference catalog describes the instrument as holding needles up to a 3-0 suture configuration. Actual needle compatibility should be confirmed.\u003c\/p\u003e\n\n\u003ch3\u003e6. What is the reference model for this instrument?\u003c\/h3\u003e\n\u003cp\u003eThe corresponding reference catalog model is B 65102, identified as an 18.5 cm straight endoscopic fascia needle holder with a 5 mm working end.\u003c\/p\u003e\n","brand":"PEAK SURGICALS","offers":[{"title":"Straight 18.5 cm   5 mm  With Locking Latch","offer_id":57625892290724,"sku":null,"price":768.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/files\/1_1c0eeb3f-fe4a-4804-92a7-857aed812d64.jpg?v=1795169897","url":"https:\/\/peaksurgicals.com\/de\/products\/endoscopic-rigid-facelift-needle-holder","provider":"PEAK SURGICALS","version":"1.0","type":"link"}