{"title":"Костни тампони и пестили","description":"\u003cstrong\u003eКостни трамбовки и чукала\u003c\/strong\u003e","products":[{"product_id":"bone-tamp","title":"Костен тампон 6 1\/4\" ортопедичен хирургически инструмент","description":"\u003ch2\u003e\u003cspan data-preserver-spaces=\"true\"\u003eКостен трамбовач 6 1\/4\" – контролирано прецизно набиване и подравняване на фрагменти\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eОсновният хирургичен инструмент за точно репониране на фрактури, прецизно поставяне на клиновидни присадки и контролирано уплътняване на костни присадки.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eКостният трамбовач 6 1\/4”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e е специализиран ортопедичен инструмент за ударно въздействие, проектиран да решава клиничния проблем с преместването, наместването или уплътняването на костни структури, без да разтрошава деликатни костни фрагменти. Със своя \u003c\/span\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eтънък, стесняващ се вал\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e и \u003c\/span\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eздрава ударна повърхност, абсорбираща сътресенията\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e, този инструмент е механично необходим за хирурзи, които повдигат ставни повърхности, уплътняват спонгиозна костна присадка или извършват окончателно пренареждане на костни фрагменти. Компактната му форма осигурява максимален ръчен контрол и позволява енергията от хирургичния чук да се предава безопасно към костта, без да ограничава видимостта.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-preserver-spaces=\"true\"\u003eОсновни характеристики за професионална медицинска употреба\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eПрецизен стесняващ се дистален връх:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Разполага с тънък, постепенно стесняващ се вал, завършващ с плосък или кръстосано назъбен ударен връх. Компактната форма е механично необходима за работа в тесни анатомични пространства и позволява насочено прилагане на сила, без да се нараняват съседните кортикални ръбове.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eДълбоко диамантено накатена ръкохватка:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Проектирана е с участък на ръкохватката с изразена текстура и накатка, обхващащ проксималната част на инструмента. Тази повърхност с високо сцепление е механично необходима за стабилен захват без приплъзване, дори при работа с хирургични ръкавици, намокрени с течности.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eМонолитна ударна повърхност от едно цяло:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Изкован е като единна конструкция от висококачествена стомана, от проксималната ударна глава до дисталния връх. Тази структурна цялост е механично необходима за предаване на 100% от силата от хирургичния чук по права линия, като същевременно предотвратява вибрациите и механичния откат.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eПрецизно калибрирана дължина 6 1\/4” (16 cm):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Перфектно балансиран, за да осигури оптимален лостов ефект, като държи ръката на хирурга близо до оперативното поле. Компактната дължина е механично необходима за намаляване на „радиуса на люлеене“ при ръчно удряне с чук и за максимална точност на траекторията.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eНерефлективно сатенено матово покритие:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Всички метални повърхности са обработени с фино матово сатенено покритие. Тази специална текстура е механично необходима за разсейване на силните лъчи от операционните лампи с оптични влакна и за предпазване на хирургичния екип от заслепяващи отблясъци.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eИзработка от неръждаема стомана за хирургични инструменти:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Изкован е от високоякостни, биологично инертни медицински стоманени сплави. Съставът на този висококачествен материал е механично необходим за устойчивост на корозионни язви, предотвратяване на микропукнатини при удар с чук и многократно преминаване през цикли на стерилизация в автоклав.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan data-preserver-spaces=\"true\"\u003eПодробно описание на продукта\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eКостният трамбовач \u003c\/span\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e6 1\/4”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e е върхово постижение в съвременните инструменти за ръчно репониране с висока тактилна чувствителност. При деликатни реконструктивни интервенции — например повдигане на хлътнал фрагмент при фрактура на тибиалното плато, наместване на кортикална костна присадка или подравняване на раздробени фрагменти — неконтролираният или директен удар с чук може лесно да разруши крехката костна структура или да измести фрагментите в неправилна посока. Този ръчен инструмент за ударно въздействие служи като незаменим механичен буфер, осигурявайки физическа защита и „контрол върху спирането на силата“, които не могат да се постигнат при манипулации с гола ръка.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eИнструментът е създаден за дълготрайна употреба и предвидимо срастване на костта. Плоската или кръстосано назъбена повърхност на върха разпределя равномерно енергията на удара върху целевата костна зона. Тази конструктивна особеност е механично необходима за предотвратяване на локални стресови фрактури или перфорация на костната стена. Действайки като здрава междинна опора, трамбовачът позволява на лекаря с леки почуквания да върне компресирани спонгиозни костни структури в правилното им анатомично положение, като възстанови подравняването и създаде стабилна основа за успешно поставяне на плака или фиксиране с винтове.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eСъздаден да надхвърля международните стандарти за качество на медицинските изделия, този компактен костен трамбовач е за многократна употреба и се почиства лесно. Устойчивата му конструкция и специалните участъци на ръкохватката със сигурен захват го превръщат в незаменимо оборудване за постигане на безопасни, организирани и високопрецизни резултати при всички комплекти за травматологична и ставно-реконструктивна хирургия.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan data-preserver-spaces=\"true\"\u003eСпецификации и клинични приложения\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eХарактеристика\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eДанни\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eОбща дължина\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e 6 1\/4 инча (159 mm \/ 16 cm)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eКонструкция на вала\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Тънък \/ постепенно стесняващ се\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eКонструкция на ръкохватката\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Диамантена накатка с високо сцепление\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eПрофил на работния връх\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Плоска \/ кръстосано назъбена ударна повърхност\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eОсновен материал\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Висококачествена неръждаема стомана за хирургични инструменти\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eПовторна обработка\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Напълно подходящ за автоклавиране \/ устойчив на стерилизация с пара под висок вакуум\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eСъответствие със стандартите\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e CE, ISO, професионален хирургичен клас\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eОсновни клинични приложения:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eПовдигане на ставната повърхност:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Връщане с леки почуквания на хлътнали костни фрагменти до правилното им положение в ставната линия при фрактури на тибиалното плато или калканеуса.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eУплътняване на костни присадки:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Уплътняване на раздробени спонгиозни костни парченца в кухинни костни дефекти за максимално увеличаване на плътността на присадката.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eНаместване на протезни компоненти:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Подпомагане на внимателното ръчно наместване с почукване на малки пробни вложки или ортопедични импланти при реконструктивни операции.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eРепониране на травматични фрактури:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Задържане на малки кортикални фрагменти в правилно положение, докато хирургът ги фиксира трайно с циркулярен серклаж или плака.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eРеконструкции в хирургията на ходилото и ръката:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Маневриране в тесни пространства между малки кости за коригиране на подравняването, без да се възпрепятства достъпът до оперативното поле.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan data-preserver-spaces=\"true\"\u003eЗащо ортопедичните специалисти избират костния трамбовач 6 1\/4”?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eБезупречно предаване на енергията:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Монолитната конструкция гарантира, че силата от чука се превръща в директно линейно изместване, което прави инструмента механично необходим за предвидим контрол върху фрагментите.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eСигурен захват без компромис:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Дълбоко накатената ръкохватка е механично необходима за стабилно задържане на инструмента при удари с чук, като предотвратява изплъзването или закачането на целевата зона.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eОптимална видимост на оперативното поле:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Изключително тънкият вал е механично необходим за безпрепятствена видимост към костната граница при работа с увеличителна оптика с висока мощност или лупи.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eОпростено централизирано обеззаразяване:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Монолитната конструкция няма вътрешни съединения, пружинни втулки или канали, което е механично необходимо за надеждна стерилизация и бърза подготовка на инструменталните тави за повторна употреба.\u003c\/span\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan data-preserver-spaces=\"true\"\u003eЧесто задавани въпроси\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eВ: Защо да се използва костен трамбовач с назъбен връх, а не с гладък кръгъл връх?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eО:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Кръстосано назъбеният връх е механично необходим за леко захващане на хлъзгава кортикална кост или влажна костна тъкан. Микротекстурата не позволява на трамбовача да се изплъзне настрани от целевата зона при удар с хирургичния чук.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eВ: Може ли този инструмент да се използва за набиване на интрамедуларни щифтове или пирони?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eО:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Не. Този костен трамбовач е буфер за ударно въздействие, предназначен за костни фрагменти и материал за присадки. За набиване на масивни метални щифтове е необходим специализиран стоманен ударен инструмент или водач за щифтове; използването на този стесняващ се трамбовач за набиване метал в метал може да деформира прецизния връх.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eВ: Какво тегло на хирургичния чук се препоръчва за този трамбовач с дължина 6 1\/4”?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eО:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Професионалният стандарт е този малък до среден модел трамбовач да се използва с лек ортопедичен чук (обикновено 7–11 oz). Съобразяването на теглото на чука с размера на инструмента е механично необходимо за предотвратяване на прекомерно силно въздействие върху малки костни сегменти.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eВ: Как трябва да се поддържа ударният връх при повторна обработка?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eО:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Професионалният стандарт е при ръчно измиване да се използва мека найлонова четка за отстраняване на уплътнения костен прах или тъканни влакна от назъбения връх. Съхранението на инструмента в специални силиконови гнезда е механично необходимо за предпазване на ръбовете от затъпяване и повреда.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eВ: Подходящ ли е този инструмент за стерилизация с пара при висока температура?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan data-preserver-spaces=\"true\"\u003eО:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan data-preserver-spaces=\"true\"\u003e Да. Конструкцията от висококачествена хирургична стомана е механично необходима за интензивна клинична употреба. Инструментът е напълно подходящ за стандартни цикли на стерилизация с пара във високовакуумен автоклав при 134°C (273°F), без помътняване на покритието или нарушаване на структурната цялост.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv id=\"gtx-trans\" style=\"position: absolute; left: 76px; top: 28px;\"\u003e\n\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e","brand":"PEAK SURGICAL","offers":[{"title":"6 1\/4\"","offer_id":42860660752548,"sku":"NB-4555","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/products\/bone-tamp-orthopedic-surgical-instruments.gif?v=1660562925"},{"product_id":"bone-chip-packer","title":"Bone Chip Packer – 10 in 2 x 9 mm Tip for Orthopedic Bone Graft Compaction","description":"\u003cp\u003eBone Chip Packer, SKU PS-000067 and part number gS 60.8510, is a reusable orthopedic graft-packing instrument manufactured from German surgical stainless steel for controlled placement and consolidation of cancellous bone chips within prepared osseous defects and fusion sites. The instrument measures 10 in overall and uses a 2 x 9 mm rectangular distal working end connected to a long rigid shaft and faceted manual handle. The narrow rectangular profile distributes packing force across a defined linear surface while preserving access within confined orthopedic and spinal operative corridors. This configuration is used during fracture-defect reconstruction, nonunion surgery, arthrodesis, cancellous bone grafting, spinal fusion, osteotomy reconstruction, and procedures where particulate autograft or allograft must be seated against a prepared recipient bed. The 10-inch length provides reach into deeper surgical sites while keeping the surgeon's hand away from the graft interface. Orthopedic trauma surgeons, spine surgeons, reconstructive specialists, foot and ankle surgeons, and neurosurgical spine teams use this pattern in hospital operating rooms and specialty surgical centers requiring focused manual graft compaction.\u003c\/p\u003e \u003ch2\u003eRectangular Working End and Axial Packing Mechanism\u003c\/h2\u003e \u003cp\u003eThe Bone Chip Packer functions through direct axial force transmitted from the proximal handle along a fixed rigid shaft to the 2 x 9 mm rectangular working surface. Unlike a round bone tamp, the distal end presents a narrow elongated footprint that can engage a strip of cancellous graft while fitting between adjacent bone margins, implants, retractors, or other instrumentation. The 2 mm dimension limits the width of the contact surface, while the 9 mm dimension distributes force longitudinally across a broader section of graft than a small circular tip. This geometry allows the surgeon to compact particulate material progressively rather than applying pressure across an unnecessarily large recipient area. The long shaft maintains alignment between the hand and distal working end and provides reach into deeper orthopedic or spinal fields. A faceted handle offers rotational control and reduces unwanted rolling in the hand or on the instrument table. There is no ratchet, pivot, spring, lock, or mechanical depth limiter. Packing pressure is therefore determined directly by hand force or measured axial impaction, working-end position, tactile resistance, and repeated visual assessment of graft distribution throughout the reconstruction.\u003c\/p\u003e \u003ch2\u003eBone Graft Placement During Orthopedic Reconstruction\u003c\/h2\u003e \u003cp\u003eDuring fracture reconstruction, the Bone Chip Packer can be introduced after reduction and preparation of a contained osseous defect when cancellous graft is required to restore local bone volume or support healing. Particulate graft is placed within the defect and the rectangular end is positioned against the material so successive controlled movements consolidate it toward the recipient surface without displacing fixation hardware. In nonunion surgery, the same pattern can assist with packing graft around a prepared nonunion site after fibrous tissue removal, decortication, and stabilization have established the reconstruction bed. During foot, ankle, or other arthrodesis procedures, the 2 x 9 mm tip can seat cancellous chips between prepared fusion surfaces while preserving clearance around plates, screws, or temporary fixation. In spinal fusion workflows, the long shaft provides access to deeper graft beds where particulate material requires controlled positioning around prepared osseous surfaces. Osteotomy reconstruction can similarly require graft packing into residual defects created after correction and stabilization. The device is used as a packer rather than a cutting or levering instrument, so force should remain directed toward the intended graft bed and away from neural, vascular, cortical, or implant structures.\u003c\/p\u003e \u003ch2\u003egS 60.8510 10-Inch Length and 2 x 9 mm Tip\u003c\/h2\u003e \u003cp\u003ePart number gS 60.8510 identifies the 10-inch Bone Chip Packer with a 2 x 9 mm rectangular distal working end. The long overall configuration provides access to recessed orthopedic and spinal operative fields while allowing the proximal handle to remain outside the immediate wound. Its 2 mm width produces a narrow contact profile for placement between restricted bony margins or alongside fixation constructs. The 9 mm longitudinal dimension increases the amount of graft contacted during each compression compared with a small round tamp, making it useful where particulate bone chips must be packed along a defined surface. This model should be distinguished from other established Bone Chip Packer configurations including 3 x 16 mm, 6 x 9 mm, 6 x 19 mm, and 6.35 mm round patterns. Those larger working ends increase contact area for broader graft beds, whereas gS 60.8510 prioritizes narrow access and focused placement. Selection should therefore reflect the dimensions of the recipient site, surgical depth, graft volume, adjacent implants, and working clearance rather than choosing a larger surface simply to increase packing speed.\u003c\/p\u003e \u003ch2\u003eGerman Stainless Steel Reprocessing and Procurement\u003c\/h2\u003e \u003cp\u003eGerman surgical stainless steel provides the rigidity, corrosion resistance, and dimensional stability required for a reusable graft-packing instrument subjected to repeated axial pressure and sterilization cycles. The solid construction allows force to travel from the handle to the rectangular distal end without a joint that could redirect the intended packing vector. Reprocessing should begin promptly after use because blood, marrow, cancellous bone particles, and graft residue can remain on the distal surface, shaft transitions, and faceted handle. Cleaning should be followed by thorough rinsing and complete drying before inspection under suitable lighting. Sterile-processing personnel should assess the 2 x 9 mm end for deformation, edge damage, retained soil, corrosion, or surface defects and confirm that the long shaft remains straight. Permanent bending can change the direction of applied force and should remove the instrument from active service until appropriately assessed. The reusable device should undergo terminal sterilization through the healthcare facility's validated process for stainless steel surgical instrumentation and applicable reprocessing instructions. Peak Surgicals supports CE and ISO 13485 procurement documentation, with FDA-related records reviewed according to institutional or distributor supplier-qualification requirements.\u003c\/p\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003ctd\u003ePS-000067\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eBone Chip Packer\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e$33.00 USD\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eSize\/Gauge Variants\u003c\/th\u003e\n\u003ctd\u003egS 60.8510: 10 in overall length with 2 x 9 mm rectangular working end\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eInstrument Category\u003c\/th\u003e\n\u003ctd\u003eOrthopedic Bone Graft Packer \/ Surgical Tamp\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eProcedure\u003c\/th\u003e\n\u003ctd\u003eFracture-defect reconstruction, nonunion surgery, arthrodesis, spinal fusion, osteotomy reconstruction, and cancellous bone graft placement\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eGerman Surgical Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eSurgical Stainless Steel Finish\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eSterilization\u003c\/th\u003e\n\u003ctd\u003eReusable; sterilize following validated healthcare-facility cleaning and reprocessing protocols\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eInstrument Classification\u003c\/th\u003e\n\u003ctd\u003eReusable Surgical Tamp\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eReusable\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, ISO 13485, FDA-related procurement documentation\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e30-Day Money-Back Guarantee\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eMOQ\u003c\/th\u003e\n\u003ctd\u003e1 Piece\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eOEM \/ Custom Orders\u003c\/th\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eAfter-Sale Service\u003c\/th\u003e\n\u003ctd\u003e30-Day Return and Exchange Support\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eHow does a Bone Chip Packer differ from a Bone Tamp?\u003c\/strong\u003e\u003cbr\u003eThe Bone Chip Packer gS 60.8510 uses a rectangular 2 x 9 mm distal surface designed specifically for controlled consolidation of particulate bone chips. A conventional Bone Tamp commonly uses a round or compact cross-serrated working end that concentrates force within a smaller circular footprint. The rectangular packer engages graft across a narrow elongated area, which can be useful along fusion beds or contained defects. A Bone Tamp provides more focal compression when material must be advanced into a small localized site. Both are fixed manual instruments without a self-retaining mechanism. Selection depends on recipient-bed geometry, graft volume, available clearance, and whether linear or focal compression better matches the reconstruction.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eWhy select the 2 x 9 mm Bone Chip Packer instead of a wider configuration?\u003c\/strong\u003e\u003cbr\u003eThe 2 x 9 mm working end provides a narrow profile for confined orthopedic and spinal graft beds. Its 2 mm width allows access between closely positioned bone margins, implants, or other instruments while the 9 mm length maintains useful contact with the graft. Wider 6 x 9 mm or 6 x 19 mm packers engage a larger surface and are better suited to broader accessible recipient sites. A 3 x 16 mm model provides an intermediate geometry with greater longitudinal contact. The Bone Chip Packer gS 60.8510 is therefore useful when access is restricted but the surgeon still requires more distributed contact than a small round tamp provides. Working-end selection should follow defect dimensions, graft volume, surgical depth, fixation position, and the space available for safe manipulation.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eWhat do CE, ISO 13485 and FDA references mean for procurement?\u003c\/strong\u003e\u003cbr\u003ePeak Surgicals displays CE, ISO, and FDA-related certification information for the Bone Chip Packer and supports ISO 13485 procurement documentation. ISO 13485 relates to the quality-management system used for controlled medical-device manufacturing and associated processes. CE documentation supports conformity assessment requirements within applicable medical-device markets. United States hospitals and distributors should review FDA-related manufacturer, establishment, listing, and device records according to their own purchasing requirements. These references should not be rewritten as an unsupported statement that PS-000067 is individually FDA approved unless that precise regulatory status is documented. Procurement teams can maintain certificates, SKU and part-number identification, purchase records, and supplier documentation within their vendor-qualification files.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow is the Bone Chip Packer controlled during graft placement?\u003c\/strong\u003e\u003cbr\u003eThe Bone Chip Packer has no ratchet, pivot, spring, or locking mechanism, so control comes directly from its faceted handle, rigid shaft, and fixed rectangular working end. The surgeon positions the 2 x 9 mm tip against the graft while aligning the shaft with the intended direction of compaction. Manual pressure or measured axial impaction then transfers force directly through the instrument toward the recipient bed. The faceted handle helps maintain rotational orientation so the long axis of the rectangular tip remains aligned with the targeted graft surface. Packing depth is judged through tactile resistance, visible graft consolidation, working-end position, and the number or intensity of controlled compressive movements. When another area requires attention, the device should be lifted and repositioned rather than rocked laterally against cortical bone, implants, or neighboring structures.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow should hospitals order and reprocess the Bone Chip Packer?\u003c\/strong\u003e\u003cbr\u003eHospitals should order this configuration using SKU PS-000067 and part number gS 60.8510 together with the 10-inch length and 2 x 9 mm tip specification. Peak Surgicals currently lists the instrument at $33.00 and provides a 30-day money-back guarantee, while eligible returns are managed under the company's 30-day return policy. Standard online ordering can begin with one instrument, and OEM requirements can be handled through Peak Surgicals for institutional or distributor procurement. After use, blood, marrow, and graft particles should be removed promptly from the distal face, shaft, transitions, and handle before residue dries. Cleaning should be followed by complete rinsing, drying, and inspection for corrosion, tip deformation, surface defects, or shaft bending. Final sterilization should follow the healthcare facility's validated reusable surgical-instrument process before PS-000067 returns to the orthopedic, trauma, or spinal instrument set.\u003c\/p\u003e","brand":"PEAK SURGICALS","offers":[{"title":"Default Title","offer_id":51423489130660,"sku":"PS-000067","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/files\/Bone_Chip_Packer.jpg?v=1787302617"},{"product_id":"bone-tamp-1","title":"Bone Tamp – 6.5 in 2 mm Cross-Serrated Tip for Bone Graft Impaction","description":"\u003cp\u003eBone Tamp, SKU PS-000068 and part number gS 60.9930, is a reusable orthopedic impaction instrument manufactured from German surgical stainless steel for controlled placement and compaction of bone graft material. The instrument measures 6 1\/2 in overall and terminates in a 2 mm cross-serrated working end designed to maintain contact with cancellous graft during precise manual impaction. Its narrow distal footprint is suited to confined osseous sites where a broader tamp would reduce visibility or occupy excessive working space. The rigid shaft transmits axial mallet force directly toward the selected graft bed while allowing the surgeon to maintain control of alignment and depth. This pattern is used during small-joint arthrodesis, foot and ankle reconstruction, fracture defect grafting, osteotomy procedures, cancellous bone graft placement, and other orthopedic workflows requiring localized graft consolidation. Orthopedic trauma surgeons, foot and ankle surgeons, reconstructive specialists, and surgical teams use this configuration where small-volume graft must be seated accurately against prepared bone surfaces without introducing a wide impaction face.\u003c\/p\u003e \u003ch2\u003e2 mm Cross-Serrated Tip and Axial Impaction Mechanism\u003c\/h2\u003e \u003cp\u003eThe working mechanism of this Bone Tamp is based on direct axial force transmission through a fixed stainless steel shaft. Its distal 2 mm face incorporates cross-serrations that create multiple intersecting contact ridges against cancellous graft. This texture increases friction at the graft interface and reduces lateral slipping when the operator begins controlled impaction. The narrow working surface concentrates applied force within a defined area, allowing small quantities of material to be advanced into a prepared defect or fusion site without compressing a broader surrounding region. Mallet impact delivered at the proximal end travels along the rigid shaft toward the distal face, so alignment of the instrument with the intended direction of graft movement is important throughout use. The device contains no pivot, ratchet, spring, lock, or mechanical depth limiter. Advancement therefore depends on the position of the working end, intensity of each mallet strike, number of impacts, tactile resistance, and direct visualization of the operative field. When another area requires compression, the tamp is lifted and repositioned rather than rocked sideways against cortical bone. This direct mechanism provides controlled graft consolidation while preserving access around adjacent instruments and exposed osseous anatomy.\u003c\/p\u003e \u003ch2\u003eBone Graft Placement During Orthopedic Reconstruction\u003c\/h2\u003e \u003cp\u003eDuring small-joint arthrodesis, the Bone Tamp can be used after articular preparation and placement of cancellous graft between the opposing fusion surfaces. The 2 mm cross-serrated end permits localized packing around narrow interfaces encountered in foot, ankle, hand, and other compact orthopedic operative fields. In fracture reconstruction, cancellous material introduced into a contained metaphyseal or cortical defect can be consolidated incrementally before definitive fixation is completed. Osteotomy procedures may similarly require graft to be seated around the corrected bone surfaces or within a residual void after alignment has been established. The tamp is positioned directly over the selected graft region, and controlled axial strikes advance the material toward the recipient bed. The surgeon reassesses distribution between sequences so graft remains within the intended space rather than being displaced away from the reconstruction. The compact working end is particularly useful when fixation plates, screws, retractors, or exposed bone margins limit access for a larger impactor. The instrument is intended for graft impaction rather than cutting, elevating, or levering bone. Effective use therefore relies on direct alignment with the graft bed and measured force appropriate to the surrounding bone quality and surgical construct.\u003c\/p\u003e \u003ch2\u003egS 60.9930 6.5-Inch Length and 2 mm Working End\u003c\/h2\u003e \u003cp\u003ePart number gS 60.9930 identifies the 6 1\/2 in Bone Tamp with a 2 mm cross-serrated distal end. The overall length provides sufficient reach from the surgeon's hand to a recessed orthopedic graft site while remaining compact enough for controlled manipulation in small operative fields. Its 2 mm diameter creates the most focused contact footprint within the associated gSource tamp family, making this configuration appropriate when precise material placement is more important than broad-area compression. The cross-serrated face distinguishes the working tip from a smooth-ended impactor by improving engagement with cancellous material during each axial strike. The long fixed shaft maintains the relationship between the proximal impact point and distal surface without an articulating joint that could redirect the applied force. Independent device records identify gS 60.9930 as a reusable surgical tamp with the same 6 1\/2 in length and 2 mm cross-serrated end published on the Peak Surgicals listing. Larger tamp diameters are used when a wider graft surface requires compression, while this PS-000068 configuration is selected for restricted anatomy, narrow fusion beds, small defects, and procedures where neighboring implants or structures limit the available working footprint.\u003c\/p\u003e \u003ch2\u003eGerman Surgical Stainless Steel and Reprocessing Workflow\u003c\/h2\u003e \u003cp\u003eGerman surgical stainless steel provides the rigidity, corrosion resistance, and dimensional stability required for repeated manual impaction and validated reprocessing. The fixed metal construction allows axial force to travel through the instrument while maintaining the geometry of the narrow 2 mm working end. Particular attention should be given to the cross-serrated surface during cleaning because blood, marrow, and cancellous graft particles can become retained within the intersecting grooves. Reprocessing should begin promptly after use, followed by thorough cleaning of the distal face, shaft, handle surfaces, and all transitions. The device should then be rinsed, completely dried, and visually inspected for residual soil, corrosion, bending, impact damage, or distortion of the serrated tip. A deformed shaft can alter the direction of transmitted force and should not be returned to an orthopedic set until addressed. The reusable tamp can undergo terminal sterilization through a healthcare facility's validated process for stainless steel surgical instrumentation and applicable instructions for use. Peak Surgicals supports CE and ISO 13485 procurement documentation, while FDA-related records should be reviewed according to the hospital or distributor's supplier-qualification requirements rather than described as individual product approval.\u003c\/p\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003cth\u003eSKU\u003c\/th\u003e\n\u003ctd\u003ePS-000068\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eBone Tamp\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003ePrice\u003c\/th\u003e\n\u003ctd\u003e$38.50 USD\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eSize\/Gauge Variants\u003c\/th\u003e\n\u003ctd\u003egS 60.9930: 6 1\/2 in overall length with 2 mm cross-serrated working end\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eInstrument Category\u003c\/th\u003e\n\u003ctd\u003eOrthopedic Bone Tamp and Graft Impactor\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eProcedure\u003c\/th\u003e\n\u003ctd\u003eSmall-joint arthrodesis, bone graft placement, fracture defect reconstruction, osteotomy grafting, and cancellous graft compaction\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eGerman Surgical Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eFinish\u003c\/th\u003e\n\u003ctd\u003eSurgical Stainless Steel Finish\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eSterilization\u003c\/th\u003e\n\u003ctd\u003eReusable; sterilize following validated healthcare-facility cleaning and reprocessing protocols\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eInstrument Classification\u003c\/th\u003e\n\u003ctd\u003eReusable Surgical Tamp\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eReusable\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, ISO 13485, FDA-related procurement documentation\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e30-Day Money-Back Guarantee\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eMOQ\u003c\/th\u003e\n\u003ctd\u003e1 Piece\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eOEM \/ Custom Orders\u003c\/th\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003cth\u003eAfter-Sale Service\u003c\/th\u003e\n\u003ctd\u003eReturn and Replacement Support\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eHow does the Bone Tamp differ from a Bone Impactor?\u003c\/strong\u003e\u003cbr\u003eThe Bone Tamp uses a narrow 2 mm cross-serrated working end designed for localized compaction of cancellous graft. A conventional Bone Impactor often uses a broader flat working surface to distribute force across a larger area of graft or bone. The smaller PS-000068 footprint provides greater access within narrow fusion beds, small osseous defects, and operative fields containing adjacent fixation hardware. Its serrated end also increases friction against the material being advanced during each axial strike. Both devices transmit manual impact rather than using a powered or locking mechanism. Selection depends on graft volume, available access, recipient-bed dimensions, and whether concentrated or distributed compression is required.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eWhy is the 2 mm Bone Tamp selected for orthopedic grafting?\u003c\/strong\u003e\u003cbr\u003eThe 2 mm working end provides a focused contact area for precise manipulation of small quantities of cancellous graft. This configuration is useful in foot, ankle, hand, and other compact orthopedic sites where a broader tip could obstruct the operative field. It also preserves clearance around plates, screws, retractors, and exposed bone margins during reconstruction. Cross-serrations reduce sliding between the instrument and graft as axial force is applied. The 6 1\/2 in overall length supplies working reach while retaining maneuverability within a restricted surgical approach. PS-000068 is therefore selected when localized graft impaction is required rather than broad compaction across a large recipient surface.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eWhat do CE, ISO 13485 and FDA references mean for procurement?\u003c\/strong\u003e\u003cbr\u003ePeak Surgicals supports CE, ISO 13485, and FDA-related procurement documentation for reusable surgical instrumentation. ISO 13485 relates to the quality-management system used for controlled medical-device manufacturing and associated processes. CE documentation supports conformity assessment requirements within applicable medical-device markets. United States hospitals and distributors should review FDA-related manufacturer and device records according to their institutional purchasing requirements. These references should not be rewritten as an unsupported statement that PS-000068 is individually FDA approved. Procurement teams can retain relevant certificates, product identification, supplier records, and purchasing documentation within their vendor-qualification files.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow is the Bone Tamp controlled during graft impaction?\u003c\/strong\u003e\u003cbr\u003eThe Bone Tamp has no ratchet, spring, pivot, lock, or adjustment mechanism. The surgeon positions the 2 mm cross-serrated end directly against the graft at the location requiring consolidation. The rigid shaft is aligned with the intended direction of material movement before axial mallet force is applied. Each controlled strike transfers energy directly to the distal working face and advances the graft incrementally. The surgeon regulates compaction through impact intensity, number of strikes, tactile resistance, tip position, and visual assessment of the recipient site. When the target changes, the instrument should be lifted and repositioned rather than levered laterally against surrounding bone or fixation hardware.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eHow should hospitals order and reprocess this Bone Tamp?\u003c\/strong\u003e\u003cbr\u003eHospitals should order the instrument using SKU PS-000068 and part number gS 60.9930 together with the 6 1\/2 in length and 2 mm tip specification. Peak Surgicals currently lists the product at $38.50 and displays a 30-day money-back guarantee. Standard ordering can begin from one piece, while OEM and custom-order support is available for institutional and distributor requirements. After use, blood, marrow, and graft residue should be removed promptly from the cross-serrated working end before debris dries within the grooves. Cleaning should be followed by thorough rinsing, complete drying, and inspection for corrosion, shaft bending, impact damage, or deformation of the distal face. Final sterilization should follow the healthcare facility's validated reusable surgical-instrument process before PS-000068 returns to the orthopedic instrument set.\u003c\/p\u003e","brand":"PEAK SURGICALS","offers":[{"title":"Default Title","offer_id":51423490375844,"sku":"PS-000068","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/files\/Bone_Tamp.jpg?v=1787302400"},{"product_id":"caspar-bone-tamp-1","title":"Caspar Bone Tamp – 8 in 3 mm Cross-Serrated Tip for Bone Graft Impaction","description":"\u003cp\u003eCaspar Bone Tamp, SKU PS-000069 and part number gS 60.7503, is a reusable orthopedic impaction instrument manufactured from German surgical stainless steel with a black plastic handle for controlled placement and compaction of bone graft material. The instrument measures 8 in overall and uses a 3 mm cross-serrated working tip that provides a focused contact surface for manipulating cancellous graft within confined osseous and spinal operative fields. The long rigid shaft transmits measured mallet force from the proximal handle to the distal tamp while keeping the surgeon's hand outside the deeper working corridor. The Caspar pattern is used during cervical and lumbar spinal fusion, interbody graft preparation, posterolateral fusion, orthopedic bone-graft reconstruction, and procedures requiring controlled consolidation of cancellous graft around prepared bone surfaces. Its narrow 3 mm end is particularly suited to localized graft placement where a broader impactor would obstruct visualization or contact adjacent structures. Spine surgeons, orthopedic reconstructive surgeons, neurosurgeons performing spinal fusion, and operating-room teams use this pattern in hospital and specialist surgical environments requiring precise manual graft impaction.\u003c\/p\u003e\n\u003ch2\u003eCross-Serrated 3 mm Tip and Direct Impaction Mechanism\u003c\/h2\u003e\n\u003cp\u003eThe Caspar design functions through direct axial impact rather than a pivot, ratchet, spring, or powered mechanism. Its distal 3 mm working end carries a cross-serrated contact pattern that increases friction between the tamp and cancellous graft during controlled advancement. The intersecting serrations reduce lateral slipping when the tip is positioned against graft material, helping maintain the intended point of compression while the surgeon or assistant delivers measured mallet strikes to the proximal end. A narrow working diameter concentrates force within a limited area, which is useful when graft must be packed into a confined spinal or orthopedic space without introducing a broad impactor. The rigid stainless steel shaft transfers impact energy along its longitudinal axis and should remain aligned with the intended direction of graft movement. At the proximal end, the black plastic handle provides a stable grip and separates the operator's hand from the metallic shaft. Because the instrument has no mechanical depth stop, impaction depth is controlled through tip position, mallet force, number of strikes, tactile resistance, and direct visualization. The tamp should be repositioned between areas of graft rather than levered laterally against surrounding bone or implants.\u003c\/p\u003e\n\u003ch2\u003eSpinal Fusion and Orthopedic Bone-Graft Workflow\u003c\/h2\u003e\n\u003cp\u003eDuring spinal fusion procedures, the Caspar Bone Tamp is used after the fusion bed or graft recipient site has been prepared and the surgeon begins placing cancellous or structural graft material into the intended space. In cervical fusion, the narrow 3 mm tip can assist with controlled packing around a prepared interbody region when localized graft placement is required without obstructing the operative corridor. During lumbar fusion, the instrument may be used to consolidate graft within accessible posterolateral or interbody preparation zones according to the selected surgical technique. In orthopedic reconstruction, the same mechanical principle applies when cancellous graft must be packed into a contained osseous defect or around a prepared fusion surface. The cross-serrated working end is positioned directly against the graft, and measured mallet strikes advance or compact the material incrementally. The surgeon reassesses distribution after each sequence so graft is consolidated without uncontrolled migration. The tamp should remain oriented toward the intended recipient site and away from neural structures, cortical margins, implants, or fragile bone. It is an impaction instrument rather than a cutting or prying device, so effective use depends on controlled axial loading and adequate visualization of the working field.\u003c\/p\u003e\n\u003ch2\u003ePS-000069 8-Inch Length and 3 mm Working Configuration\u003c\/h2\u003e\n\u003cp\u003ePS-000069 corresponds to part number gS 60.7503 and is supplied with an 8 in overall length and 3 mm distal working end. The 3 mm diameter provides a narrow impaction footprint for focused graft placement within confined anatomy. This smaller contact area allows the surgeon to direct compression toward a specific graft region while preserving working clearance for retractors, suction instruments, implants, or other spinal instrumentation. The 8 in overall length provides reach to deeper operative sites while keeping the proximal grip outside the immediate wound. Its stainless steel shaft supplies the rigidity required to transmit repeated axial impact without depending on a jointed mechanism. The black plastic handle provides a broad proximal gripping surface and helps the operator maintain alignment during positioning and mallet contact. Although Caspar bone tamps are manufactured in additional tip diameters by established instrument systems, this Peak Surgicals listing identifies the gS 60.7503 configuration with a 3 mm tip. Selection of this model is therefore appropriate when the surgical workflow requires localized graft consolidation rather than the broader contact area produced by larger tamp diameters.\u003c\/p\u003e\n\u003ch2\u003eGerman Stainless Steel, Handle Care and Reprocessing Standards\u003c\/h2\u003e\n\u003cp\u003eGerman surgical stainless steel provides the rigidity, corrosion resistance, and dimensional stability required for a reusable bone tamp exposed to repeated impaction loads. The distal cross-serrated surface requires particular attention during reprocessing because blood, marrow, and graft particles can lodge within the intersecting grooves. Cleaning should begin promptly after use and include the 3 mm working end, shaft transitions, and junction between the metal body and black plastic handle. Thorough rinsing and complete drying should follow before functional inspection. Sterile-processing personnel should examine the serrations for retained debris, deformation, surface damage, or corrosion and confirm that the shaft remains straight without impact-related distortion. The handle should remain secure and intact without cracking, looseness, or other damage that could compromise control during mallet use. Reprocessing and terminal sterilization should follow the healthcare facility's validated protocol and applicable manufacturer instructions for a reusable instrument containing both stainless steel and a plastic handle. Peak Surgicals displays CE, ISO, and FDA-related certification information for this product, while institutional buyers should retain the applicable documentation within their supplier-qualification and procurement records.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; height: 470.333px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 19.5972px;\"\u003eSKU\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 19.5972px;\"\u003ePS-000069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 19.5972px;\"\u003eProduct Name\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 19.5972px;\"\u003eCaspar Bone Tamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 19.5972px;\"\u003ePrice\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 19.5972px;\"\u003e$60.50 USD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 39.1944px;\"\u003eSize\/Gauge Variants\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 39.1944px;\"\u003egS 60.7503: 8 in overall length with 3 mm working tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 39.1944px;\"\u003eInstrument Category\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 39.1944px;\"\u003eOrthopedic and Spine Bone Tamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7917px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 58.7917px;\"\u003eProcedure\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 58.7917px;\"\u003eCervical spinal fusion, lumbar fusion, interbody graft placement, posterolateral fusion, orthopedic bone-graft reconstruction, and cancellous graft compaction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 19.5972px;\"\u003eMaterial\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 19.5972px;\"\u003eGerman Surgical Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 19.5972px;\"\u003eFinish\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 19.5972px;\"\u003eSurgical stainless steel shaft with black plastic handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 39.1944px;\"\u003eSterilization\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 39.1944px;\"\u003eReusable; clean and sterilize according to validated healthcare-facility protocols and applicable reprocessing instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 39.1944px;\"\u003eInstrument Classification\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 39.1944px;\"\u003eReusable Manual Orthopedic Bone Tamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 19.5972px;\"\u003eReusable\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 19.5972px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 19.5972px;\"\u003eCertifications\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 19.5972px;\"\u003eCE, ISO 13485, FDA-related procurement documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 19.5972px;\"\u003eWarranty\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 19.5972px;\"\u003e30-Day Money-Back Guarantee\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5972px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 19.5972px;\"\u003eMOQ\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 19.5972px;\"\u003e1 Piece for standard store ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 39.1944px;\"\u003eOEM \/ Custom Orders\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 39.1944px;\"\u003eAvailable through Peak Surgicals bulk and private-label manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1944px;\"\u003e\n\u003cth style=\"width: 20.8482%; height: 39.1944px;\"\u003eAfter-Sale Service\u003c\/th\u003e\n\u003ctd style=\"width: 76.5327%; height: 39.1944px;\"\u003eReturn and replacement support under Peak Surgicals policy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eHow does a Caspar Bone Tamp differ from a standard Bone Impactor?\u003c\/strong\u003e\u003cbr\u003eThe Caspar Bone Tamp uses a narrow 3 mm cross-serrated working end designed for focused graft placement and controlled compaction. A standard Bone Impactor commonly has a broader flat or removable impact surface intended to distribute force across a larger graft or bone area. The Caspar pattern therefore provides more localized contact when the operative corridor is narrow or the surgeon needs to direct graft into a defined region. Its cross-serrated face also increases friction against cancellous material during axial impaction. Both instruments transfer mallet force manually and contain no locking mechanism. Selection depends on the size of the graft bed, available access, required contact area, and whether focused or broader impaction is needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is a 3 mm tip selected for the Caspar Bone Tamp?\u003c\/strong\u003e\u003cbr\u003eThe 3 mm tip provides a small contact footprint for precise graft placement within confined spinal and orthopedic operative spaces. This is useful when cancellous material must be consolidated near a defined fusion surface without introducing a wider impactor into the field. The narrow end also preserves clearance around retractors, implants, and other instruments during graft placement. Cross-serrations help stabilize the graft at the contact point as axial force is applied. The 8 in shaft provides reach while the surgeon's hand remains outside the deeper corridor. PS-000069 should therefore be selected when localized impaction is required rather than when a broad surface must be compressed simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do CE, ISO 13485 and FDA references mean for procurement?\u003c\/strong\u003e\u003cbr\u003ePeak Surgicals displays CE, ISO, and FDA-related certification information for the Caspar Bone Tamp. ISO 13485 concerns the quality-management system used for controlled medical-device manufacturing and associated processes. CE documentation supports conformity assessment requirements within applicable medical-device markets. United States hospitals and distributors should evaluate FDA-related manufacturer and device records according to their own purchasing requirements. Regulatory references should not be rewritten as an unsupported statement that PS-000069 is individually FDA approved unless that exact status is documented. Procurement teams can retain product identification, certificates, supplier records, and purchasing documentation within institutional vendor-qualification files.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is impaction controlled when the Caspar Bone Tamp has no mechanical adjustment?\u003c\/strong\u003e\u003cbr\u003eThe Caspar Bone Tamp is a fixed manual instrument with no ratchet, pivot, spring, or locking mechanism. The surgeon places the 3 mm cross-serrated tip directly against the bone graft at the intended point of compression. The rigid shaft is aligned with the desired direction of graft movement before a mallet strike is delivered to the proximal end. Each impact transfers axial force through the shaft to the narrow working surface. Depth and compaction are controlled by strike intensity, number of impacts, tip position, tactile resistance, and repeated visual assessment. The instrument should be lifted and repositioned when the target area changes rather than rocked sideways against bone or adjacent instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should hospitals order and reprocess the Caspar Bone Tamp?\u003c\/strong\u003e\u003cbr\u003eHospitals should order this product using SKU PS-000069 and part number gS 60.7503 together with the 8 in length and 3 mm tip specification. Peak Surgicals currently lists the instrument at $60.50 and displays a 30-day money-back guarantee. The standard online ordering unit is one instrument, while bulk and private-label manufacturing services are available through Peak Surgicals for institutional and distributor requirements. Following use, graft, blood, and marrow residue should be removed promptly from the cross-serrated tip and shaft before material dries within the grooves. The instrument should then be cleaned, rinsed, dried, and inspected for tip deformation, shaft bending, corrosion, or damage to the black plastic handle. Final sterilization should follow the facility's validated process and applicable reprocessing instructions before PS-000069 returns to the orthopedic or spinal instrument set.\u003c\/p\u003e","brand":"PEAK SURGICALS","offers":[{"title":"Default Title","offer_id":51423490736292,"sku":"PS-000069","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/files\/Caspar_Bone_Tamp.jpg?v=1787302044"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/collections\/Bone_Chip_Packer.webp?v=1794042818","url":"https:\/\/peaksurgicals.com\/bg\/collections\/bone-tamps-and-pestles.oembed","provider":"PEAK SURGICALS","version":"1.0","type":"link"}