{"product_id":"putterman-muscle-clamp-with-ratchet","title":"Putterman Muscle Clamp with Ratchet","description":"\n\u003ch2\u003ePutterman Muscle Clamp with Ratchet – 10cm, 6 Pins\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003ePutterman Muscle Clamp with Ratchet\u003c\/strong\u003e is a specialized stainless steel ophthalmic surgical instrument designed for clamping the conjunctiva and Müller’s muscle during selected upper eyelid ptosis procedures. Featuring an atraumatic toothed T-shaped working head and spring ratchet mechanism, this instrument provides a dedicated clamping configuration for oculoplastic surgery.\u003c\/p\u003e\n\n\u003cp\u003eMeasuring \u003cstrong\u003e4 inches (10 cm)\u003c\/strong\u003e in overall length, the Putterman Clamp features a six-pin working-end design and an integrated sliding closure mechanism. Its compact construction distinguishes it from conventional tissue forceps and general-purpose surgical clamps.\u003c\/p\u003e\n\n\u003ch2\u003eInstrument Design and Features\u003c\/h2\u003e\n\n\u003ch3\u003eT-Shaped Atraumatic Clamping Head\u003c\/h3\u003e\n\n\u003cp\u003eThe Putterman Muscle Clamp incorporates a T-shaped working head designed to engage the conjunctiva and Müller’s muscle during selected eyelid procedures.\u003c\/p\u003e\n\n\u003cp\u003eThe manufacturer identifies the working end as an atraumatic toothed configuration with six pins. This specialized jaw arrangement is designed for tissue fixation during the clamping stage of the procedure.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument's toothed working head is distinct from smooth-jawed forceps and conventional straight clamping instruments.\u003c\/p\u003e\n\n\u003cp\u003eAppropriate tissue positioning, clamp placement, and applied pressure must be determined by the operating surgeon according to eyelid anatomy and the intended surgical technique.\u003c\/p\u003e\n\n\u003ch3\u003eSpring Ratchet Closure Mechanism\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003ePutterman Ratchet Clamp\u003c\/strong\u003e features a spring-controlled ratchet mechanism that regulates closure of the working end.\u003c\/p\u003e\n\n\u003cp\u003eThe central sliding control allows the surgeon to operate the clamping mechanism and maintain the selected jaw position during the relevant surgical stage.\u003c\/p\u003e\n\n\u003cp\u003eThe ratchet is designed to reduce the need for continuous manual closure pressure. Its function depends on correct instrument operation and appropriate tissue placement.\u003c\/p\u003e\n\n\u003ch3\u003eStainless Steel Construction\u003c\/h3\u003e\n\n\u003cp\u003eThe instrument is manufactured from stainless steel and incorporates a compact elongated body with a specialized transverse clamping head.\u003c\/p\u003e\n\n\u003cp\u003eIts construction includes the T-shaped working end, flat body, sliding ratchet assembly, and terminal handling section.\u003c\/p\u003e\n\n\u003cp\u003eThe working head and mechanical closure components should be inspected before clinical use for visible damage, deformation, misalignment, or irregular movement.\u003c\/p\u003e\n\n\u003ch3\u003eFlat Handle and Sliding Control\u003c\/h3\u003e\n\n\u003cp\u003eThe Putterman Clamp has a flattened body with an integrated sliding control positioned along its central section.\u003c\/p\u003e\n\n\u003cp\u003eThe sliding component provides a defined contact area for operating the ratchet mechanism. The opposite end of the instrument forms a transverse handle section.\u003c\/p\u003e\n\n\u003cp\u003eThis handle and ratchet arrangement distinguishes the Putterman pattern from ring-handled hemostatic clamps and conventional thumb forceps.\u003c\/p\u003e\n\n\u003ch2\u003eClinical Applications in Oculoplastic Surgery\u003c\/h2\u003e\n\n\u003ch3\u003eMüller’s Muscle–Conjunctival Resection (MMCR)\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003ePutterman Ptosis Clamp\u003c\/strong\u003e is associated with Müller’s muscle–conjunctival resection, a posterior approach used in selected cases of upper eyelid ptosis.\u003c\/p\u003e\n\n\u003cp\u003eDuring the procedure, the instrument is used to secure the conjunctiva and Müller’s muscle for the planned surgical steps.\u003c\/p\u003e\n\n\u003cp\u003eThe clamp provides a holding arrangement for the selected tissue before the surgeon performs the applicable suturing and resection technique.\u003c\/p\u003e\n\n\u003cp\u003eSelection of the procedure and instrument depends on the patient's eyelid anatomy, clinical assessment, and the operating surgeon's technique.\u003c\/p\u003e\n\n\u003ch3\u003eUpper Eyelid Ptosis Surgery\u003c\/h3\u003e\n\n\u003cp\u003eUpper eyelid ptosis surgery may involve techniques that require controlled tissue fixation and resection. The Putterman Muscle Clamp is specifically associated with procedures involving the superior tarsal conjunctiva and Müller’s muscle.\u003c\/p\u003e\n\n\u003cp\u003eIts T-shaped jaw configuration and ratchet mechanism provide a specialized instrument design for these operative steps.\u003c\/p\u003e\n\n\u003cp\u003eThe instrument is relevant to ophthalmologists, oculoplastic surgeons, ophthalmic surgical departments, specialist eye clinics, and hospitals maintaining ptosis surgery instrumentation.\u003c\/p\u003e\n\n\u003ch2\u003ePutterman Clamp vs. Conventional Tissue Forceps\u003c\/h2\u003e\n\n\u003cp\u003eConventional tissue forceps are typically used for grasping and manipulating tissue during a wide range of surgical procedures.\u003c\/p\u003e\n\n\u003cp\u003eThe Putterman Clamp incorporates a specialized T-shaped clamping head and spring ratchet intended for securing conjunctival and Müller’s muscle tissue during selected eyelid procedures.\u003c\/p\u003e\n\n\u003cp\u003eIts configuration is procedure-specific and should not be considered a general substitute for ophthalmic forceps or other eyelid clamps.\u003c\/p\u003e\n\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n      \u003ctd\u003ePutterman Muscle Clamp with Ratchet\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eInstrument Pattern\u003c\/th\u003e\n      \u003ctd\u003ePutterman\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eCatalog Reference\u003c\/th\u003e\n      \u003ctd\u003eB 60079\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eInstrument Type\u003c\/th\u003e\n      \u003ctd\u003eOphthalmic Muscle Clamp \/ Ptosis Clamp\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n      \u003ctd\u003eStainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eOverall Length\u003c\/th\u003e\n      \u003ctd\u003e4 inches \/ 10 cm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eWorking End\u003c\/th\u003e\n      \u003ctd\u003eT-Shaped Clamping Head\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eJaw Design\u003c\/th\u003e\n      \u003ctd\u003eAtraumatic Toothed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003ePin Configuration\u003c\/th\u003e\n      \u003ctd\u003e6 Pins\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eMechanism\u003c\/th\u003e\n      \u003ctd\u003eSpring Ratchet with Sliding Closure Control\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eHandle Design\u003c\/th\u003e\n      \u003ctd\u003eFlat Elongated Body with T-Shaped End\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003ePrimary Specialty\u003c\/th\u003e\n      \u003ctd\u003eOphthalmology \/ Oculoplastic Surgery\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eClinical Application\u003c\/th\u003e\n      \u003ctd\u003eConjunctiva and Müller’s Muscle Clamping\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"row\"\u003eAssociated Procedure\u003c\/th\u003e\n      \u003ctd\u003eMüller’s Muscle–Conjunctival Resection (MMCR)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstrument Inspection and Handling\u003c\/h2\u003e\n\n\u003cp\u003eBefore clinical use, inspect the T-shaped clamping head and its toothed surfaces for visible wear, deformation, or damage.\u003c\/p\u003e\n\n\u003cp\u003eExamine the spring ratchet and sliding mechanism for appropriate mechanical movement. Confirm that the working head closes and releases as intended according to the applicable manufacturer instructions.\u003c\/p\u003e\n\n\u003cp\u003eClean and process the instrument according to its product-specific reprocessing instructions and the healthcare facility's validated instrument-processing procedures.\u003c\/p\u003e\n\n\u003cp\u003eParticular attention should be given to the toothed working surfaces, sliding assembly, and areas surrounding the ratchet during cleaning and inspection.\u003c\/p\u003e\n\n\u003cp\u003eDo not assume specific sterilization temperatures, exposure times, pressures, or processing cycles without verified product instructions.\u003c\/p\u003e\n\n\u003cp\u003eDuring storage and transportation, protect the working head and mechanical components from contact damage.\u003c\/p\u003e\n\n\u003ch2\u003eOrdering the Putterman Muscle Clamp with Ratchet\u003c\/h2\u003e\n\n\u003cp\u003ePeak Surgicals supplies specialized surgical instruments for ophthalmic surgical departments, oculoplastic practices, hospitals, specialist eye clinics, distributors, and medical procurement professionals.\u003c\/p\u003e\n\n\u003cp\u003eWhen selecting this instrument, specify the \u003cstrong\u003ePutterman Muscle Clamp with Ratchet, 10 cm overall length, and six-pin T-shaped working head\u003c\/strong\u003e. The corresponding reference catalog model is B 60079.\u003c\/p\u003e\n\n\u003cp\u003eExplore related \u003ca href=\"\/ar\/collections\/ophthalmology-instruments\"\u003eOphthalmology Instruments\u003c\/a\u003e for additional surgical tools used in eyelid, conjunctival, and other ophthalmic procedures.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch3\u003e1. What is the Putterman Muscle Clamp used for?\u003c\/h3\u003e\n\u003cp\u003eIt is used to clamp the conjunctiva and Müller’s muscle during selected upper eyelid ptosis procedures, particularly Müller’s muscle–conjunctival resection.\u003c\/p\u003e\n\n\u003ch3\u003e2. What is the overall length of the instrument?\u003c\/h3\u003e\n\u003cp\u003eThe Putterman Muscle Clamp measures 4 inches (10 cm) in overall length.\u003c\/p\u003e\n\n\u003ch3\u003e3. What type of working end does the clamp feature?\u003c\/h3\u003e\n\u003cp\u003eIt features an atraumatic toothed, T-shaped clamping head with six pins.\u003c\/p\u003e\n\n\u003ch3\u003e4. Does the instrument have a ratchet mechanism?\u003c\/h3\u003e\n\u003cp\u003eYes. It incorporates a spring ratchet with a sliding closure control.\u003c\/p\u003e\n\n\u003ch3\u003e5. What material is the Putterman Clamp made from?\u003c\/h3\u003e\n\u003cp\u003eThe instrument is manufactured from stainless steel.\u003c\/p\u003e\n\n\u003ch3\u003e6. What is the catalog reference for this model?\u003c\/h3\u003e\n\u003cp\u003eThe reference model is B 60079, identifying the 10 cm Putterman Muscle Clamp with Ratchet and six-pin working head.\u003c\/p\u003e\n","brand":"PEAK SURGICALS","offers":[{"title":"10 cm \/ 4″","offer_id":57625843171492,"sku":"PS-J-176","price":54.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0465\/2679\/1844\/files\/1_eee9e103-822b-495f-b226-f6b68a08ca9a.jpg?v=1795163967","url":"https:\/\/peaksurgicals.com\/ar\/products\/putterman-muscle-clamp-with-ratchet","provider":"PEAK SURGICALS","version":"1.0","type":"link"}